background image

User reference guide 

Daikin room air conditioner

FTXP20N5V1B9
FTXP25N5V1B9
FTXP35N5V1B9

ATXP20N5V1B9
ATXP25N5V1B9
ATXP35N5V1B9

Summary of Contents for FTXP35N5V1B9

Page 1: ...User reference guide Daikin room air conditioner FTXP20N5V1B9 FTXP25N5V1B9 FTXP35N5V1B9 ATXP20N5V1B9 ATXP25N5V1B9 ATXP35N5V1B9...

Page 2: ...rt airflow operation 20 5 6 1 To start stop Comfort airflow operation 20 5 7 Powerful operation 21 5 7 1 To start stop Powerful operation 21 5 8 Econo operation 21 5 8 1 To start stop Econo operation...

Page 3: ...ing operation or idle time is heard 38 8 1 6 Symptom A clapping sound is heard 38 8 1 7 Symptom White mist comes out of a unit Indoor unit 38 8 1 8 Symptom The units can give off odours 38 8 1 9 Sympt...

Page 4: ...box of the indoor unit Operation manual Quick guide for basic usage Format Paper in the box of the indoor unit User reference guide Detailed step by step instructions and background information for b...

Page 5: ...uld result in equipment or property damage INFORMATION Indicates useful tips or additional information Symbols used on the unit Symbol Explanation Before installation read the installation and operati...

Page 6: ...reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the...

Page 7: ...symbol this chemical symbol means that the battery contains a heavy metal above a certain concentration Possible chemical symbols are Pb lead 0 004 Waste batteries MUST be treated at a specialised tr...

Page 8: ...type insecticide Chemicals could collect in the unit and endanger the health of people who are hypersensitive to chemicals WARNING The refrigerant inside the unit is mildly flammable but normally doe...

Page 9: ...g use check the unit stand and fitting for damage If damaged the unit may fall and result in injury WARNING Be careful with ladders when working in high places WARNING Improper detergents or cleaning...

Page 10: ...ry INFORMATION The sound pressure level is less than 70 dBA WARNING Do NOT modify disassemble remove reinstall or repair the unit yourself as incorrect dismantling or installation may cause an electri...

Page 11: ...the user interface Wireless remote control INFORMATION The indoor unit is delivered with the wireless remote control as the user interface This manual describes only operation with this user interface...

Page 12: ...8 b l k c d e f j i h g a a Signal receiver b OFF button c Fan setting button d Econo operation button e Swing buttons f Timer setting buttons ON OFF cancel g Powerful operation button h Comfort opera...

Page 13: ...Medium high Airflow rate Medium Airflow rate Medium low Airflow rate Low Comfort operation is active Automatic vertical swing is active Automatic horizontal swing is active ON timer is active OFF time...

Page 14: ...s remote control Fixing the wireless remote control to the wall Turning on the power supply 4 2 To insert the batteries The batteries will last for about 1 year 1 Remove the back cover 2 Insert both b...

Page 15: ...uide 15 FTXP20 35N5V1B9 ATXP20 35N5V1B9 Daikin room air conditioner 4D520466 17M 2023 08 4 4 To turn on the power supply 1 Turn the circuit breaker on Result The flap of the indoor unit will open and...

Page 16: ...t runs outside its operation range b Condensation and water dripping might occur if the unit runs outside its operation range 5 2 When to use which feature You can use the following table to determine...

Page 17: ...omatic The system cools down or heats up a room to the temperature setpoint It automatically switches between cooling and heating if necessary Drying The system decreases the humidity in a room Heatin...

Page 18: ...e or more times to set the temperature You CANNOT adjust the temperature in drying or fan only operation mode Cooling operation Heating operation Automatic operation Drying or fan only operation 18 32...

Page 19: ...flap varies according to the operation mode The flap will stop at the upper position when the airflow rate is changed to low during the up and down swing setting a b c a Flap range in cooling or dryin...

Page 20: ...osition press and when the flaps and louvers reach the desired position Result and disappear from the LCD The flaps and the louvers will stop moving 5 6 Comfort airflow operation This operation can be...

Page 21: ...e airflow rate is fixed to the maximum setting INFORMATION Powerful operation CANNOT be used together with Econo and Comfort airflow operation The last selected function takes priority Powerful operat...

Page 22: ...ion b Maximum during Econo operation c Normal operation d Econo operation The diagram is for illustrative purposes only The maximum running current and power consumption of the air conditioner in Econ...

Page 23: ...Press again if you want to change the time setting INFORMATION Each time is pressed the time setting advances by 1 hour The timer can be set between 1 to 12 hours Example If is set when the unit is o...

Page 24: ...starts in 2 hours and then stops 3 hours later 5 10 Wireless LAN connection The customer is responsible for providing Smartphone or tablet with minimum supported version of Android or iOS specified on...

Page 25: ...re information and FAQ refer to app daikineurope com 1 Stop operation before setting the wireless connection 2 Use the wireless remote control to select the wireless LAN setting menu Note During setti...

Page 26: ...button To reset the connection setting to the factory default Reset the connection setting to the factory default in case you want to disconnect the wireless LAN and the communication device e g rout...

Page 27: ...nditioner 4D520466 17M 2023 08 5 sec 1 OFF 3 Hold for at least 2 seconds to confirm the selection Result is blinking The operation and timer LEDs are blinking alternately in 1 s interval Communication...

Page 28: ...ing curtains or blinds Make sure the area is well ventilated Do NOT block any ventilation openings Ventilate often Extended use requires special attention to ventilation Keep doors and windows closed...

Page 29: ...ration User reference guide 29 FTXP20 35N5V1B9 ATXP20 35N5V1B9 Daikin room air conditioner 4D520466 17M 2023 08 Operate the system within the recommended temperature range 26 28 C for cooling and 20 2...

Page 30: ...equire shorter maintenance intervals WARNING The refrigerant inside the unit is mildly flammable but normally does NOT leak If the refrigerant leaks in the room and comes in contact with fire from a b...

Page 31: ...cleaning be sure to stop the operation turn the breaker OFF or pull out the supply cord Otherwise an electrical shock and injury may result NOTICE Do NOT use gasoline benzene thinner polishing powder...

Page 32: ...CANNOT clean the air poor heating cooling causes odour 7 5 To open the front panel 1 Hold the front panel by the panel tabs on both sides and open it 7 6 To clean the air filters 1 Push the tab at the...

Page 33: ...ir filters in the shade It is recommended to clean the air filters every 2 weeks INFORMATION If the dust does NOT come off easily wash the air filters with a neutral detergent diluted in lukewarm wate...

Page 34: ...the titanium apatite deodorising filter and the silver particle filter Ag ion filter INFORMATION Replace the filter every 3 years 1 Remove the filter from the tabs of the filter frame and replace the...

Page 35: ...lace them in their original positions 4 Remove the batteries from the wireless remote control INFORMATION It is recommended to have periodical maintenance performed by a specialist For specialist main...

Page 36: ...number the operation lamp flashes and the malfunction code appears Notify your installer and report the malfunction code If the system does NOT operate properly except for the above mentioned cases a...

Page 37: ...unit operates in Econo operation Refer to 5 8 Econo operation 421 Check if there is any furniture directly under or next to the indoor unit Move the furniture An abnormal function happens during oper...

Page 38: ...clicking sound during operation or idle time is heard This sound is generated when the refrigerant control valves or electrical parts operate 8 1 6 Symptom A clapping sound is heard This sound is gene...

Page 39: ...cal dealer INFORMATION See the service manual for The complete list of error codes A more detailed troubleshooting guideline for each error To check the error code by the wireless remote control 1 Aim...

Page 40: ...abnormality Outdoor temperature thermistor abnormality Discharge pipe thermistor abnormality Outdoor heat exchanger thermistor abnormality Electrical parts heat error Radiation fin temperature rise In...

Page 41: ...t 426 The wireless LAN is NOT visible in the available Wi Fi networks list on the smart device Access point option Try switching between access point and WPS setting to change the wireless channel The...

Page 42: ...er 4D520466 17M 2023 08 9 Disposal NOTICE Do NOT try to dismantle the system yourself dismantling of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation...

Page 43: ...any which can perform or coordinate the required service to the product Installation manual Instruction manual specified for a certain product or application explaining how to install configure and ma...

Page 44: ...ANBUL T RK YE Tel 0216 453 27 00 Faks 0216 671 06 00 a r Merkezi 444 999 0 Web www daikin com tr G lsuyu Mahallesi Fevzi akmak Caddesi Bur ak Sokak No 20 34848 Maltepe 4D520466 17M 2023 08 Copyright 2...

Reviews: