background image

21

1. Open the top front panel. 

• Open the top front panel by placing a finger on the 

panel tab on either side of the top front panel and 
then secure it using the supporting plate on the right.

2. Pull out the air filters.

• Push a little upwards the tab at the center of 

each air  filter, then pull it down. 

3. Take off the Titanium Apatite 

Photocatalytic Air-Purifying Filter.

• Hold the recessed parts of the frame and 

unhook the four claws.

4. Clean or replace each filter.

See figure.

5. Set the air filter and the Titanium Apatite 

Photocatalytic Air-Purifying Filter as they 
were and close the front grille.

• Be sure to insert the two tabs below.
• Return the supporting plate to its previous position.
• Press either side of the top front panel.

Air Filter

1. Wash the air filters with water or clean them with 

vacuum cleaner.

• If the dust does not come off easily, wash them with neutral detergent 

thinned with  lukewarm water, then dry them up in the shade.

• It is recommended to clean the air filters every two weeks.

Titanium Apatite Photocatalytic 
Air-Purifying Filter. (gray)

The Titanium Apatite Photocatalytic Air-Purifying Filter can be renewed 
by washing it with water once every 6 months. We recommend replacing it once every 3 years.

[ Maintenance ]

1. Remove dust with a vacuum cleaner and wash lightly with water.
2. If it is very dirty, soak it for 10 to 15 minutes in water mixed with a neutral cleaning agent.
3. Do not remove filter from frame when washing with water.
4. After washing, shake off remaining water and dry in the shade.
5. Since the material is made out of paper, do not wring out the filter when removing water from it.

[ Replacement]

1. Remove the tabs on the filter frame and replace with a new filter.

• Dispose of the old filter as flammable waste.

Filters

Supporting plate

Air filter

Titanium Apatite 
Photocatalytic 
Air-Purifying Filter

Filter frame

Tab

Push

Tab

01_EN_3P119312-2C.fm  Page 21  Thursday, October 13, 2005  2:30 PM

Summary of Contents for FTXG25CVMAW

Page 1: ...FTXG25CVMAW FTXG25CVMAS FTXG35CVMAW FTXG35CVMAS MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual...

Page 2: ...aration Before Operation 7 OPERATION AUTO DRY COOL HEAT FAN Operation 10 Adjusting the Air Flow Direction 12 POWERFUL Operation 14 OUTDOOR UNIT SILENT Operation 15 INTELLIGENT EYE Operation 16 TIMER O...

Page 3: ...may be leaking so call your dealer When carrying out repairs accompanying adding refrigerant check the content of the repairs with our service staff Do not attempt to install the air conditioner by yo...

Page 4: ...tdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunc tions smoke...

Page 5: ...4 Names of parts Indoor Unit 15 14 18 12 13 17 1 3 4 6 2 11 16 5 7 8 9 10 With the panel closed...

Page 6: ...he remote controller is missing 13 Room temperature sensor It senses the air temperature around the unit 14 Operation lamp green 15 TIMER lamp yellow page 18 16 INTELLIGENT EYE lamp green page 16 17 I...

Page 7: ...on once to start operation Press once again to stop it 7 MODE selector button It selects the operation mode AUTO DRY COOL HEAT FAN page 10 8 SILENT button for OUTDOOR UNIT SILENT operation page 15 9 F...

Page 8: ...es together When the system is not used for a long time take the batteries out We recommend replacing once a year although if the remote controller display begins to fade or if reception deteriorates...

Page 9: ...urn on the power breaker Turning on the power breaker will cause the panel and flap to open once and then close again This is a normal procedure CAUTION ATTENTION During operation i e when the panel i...

Page 10: ...are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Operation outside this humidity or...

Page 11: ...dvances the mode setting in sequence AUTO DRY COOL HEAT FAN 2 Press ON OFF button The operation lamp will light up and the panel will open To stop operation 3 Press ON OFF button again The operation l...

Page 12: ...er the start of heating operation it takes some time before the room gets warmer In heating operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switche...

Page 13: ...more The flap will stop moving To adjust the vertical blades louvers 3 Press SWING button is displayed on the LCD 4 When the louvers have reached the desired position press the SWING button once more...

Page 14: ...rflow circulates cold air which tends to collected at the bottom of the room and hot air which tends to collect near the ceiling throughout the room preventing areas of cold and hot developing Comfort...

Page 15: ...s displayed on the LCD To cancel POWERFUL operation 2 Press POWERFUL button again NOTE Notes on POWERFUL operation In COOL and HEAT mode To maximize the cooling heating effect the capacity of outdoor...

Page 16: ...el OUTDOOR UNIT SILENT operation 2 Press SILENT button again NOTE Note on OUTDOOR UNIT SILENT operation This function is available in COOL HEAT and AUTO modes This is not available in FAN and DRY mode...

Page 17: ...displayed on the LCD To cancel the INTELLIGENT EYE operation 2 Press SENSOR button again EX When somebody in the room Normal operation The INTELLIGENT EYE lamp lights up When nobody in the room 20 min...

Page 18: ...passersby temperature range etc The sensor also mistakenly detects pets sunlight fluttering curtains and light reflected off of mirrors as passersby INTELLIGENT EYE operation will not go on during pow...

Page 19: ...ng down either button changes the setting rapidly 3 Press OFF TIMER button again The TIMER lamp lights up To cancel the OFF TIMER operation 4 Press CANCEL button The TIMER lamp goes off Notes When TIM...

Page 20: ...r button changes the setting rapidly 3 Press ON TIMER button again The TIMER lamp lights up To cancel ON TIMER operation 4 Press CANCEL button The TIMER lamp goes off To combine ON TIMER and OFF TIMER...

Page 21: ...the top front panel Place the revolving axes on either side of the top front panel into the holes and slowly close Press either side of the top front panel CAUTION Units Don t touch the metal parts o...

Page 22: ...ot come off easily wash them with neutral detergent thinned with lukewarm water then dry them up in the shade It is recommended to clean the air filters every two weeks Titanium Apatite Photocatalytic...

Page 23: ...indoor unit and the outdoor unit Check that the drain comes smoothly out of the drain hose during COOL or DRY operation If no drain water is seen water may be leaking from the indoor unit Stop operat...

Page 24: ...nditioner is in defrost operation In COOL or DRY mode Moisture in the air condenses into water on the cool surface of outdoor unit piping and drips Mists come out of the indoor unit This happens when...

Page 25: ...the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it...

Page 26: ...ner may get foul after several seasons of use resulting in poor performance It is recommended to have periodical maintenance by a specialist aside from regular cleaning by the user For specialist main...

Page 27: ...26 MEMO...

Page 28: ...27 MEMO...

Page 29: ...28 MEMO...

Page 30: ...0512 HT 3P119312 2C M03B039B...

Reviews: