22
FAQ
Indoor unit
Outdoor unit
Operation does not start soon.
When
or any direct operation button was
pressed soon after operation was stopped.
When the mode was reselected.
•
This is to protect the air conditioner.
You should wait for about 3 minutes.
HEAT operation stops suddenly and
a flowing sound is heard.
•
The outdoor unit is defrosting. HEAT operation starts
after the frost on the outdoor unit has been removed.
This can take about 4 to 12 minutes.
The air conditioner stops generating
airflow during HEAT operation.
•
Once the set temperature is reached, the airflow rate is
reduced and operation stopped in order to avoid
generating a cool airflow. Operation will resume
automatically when the indoor temperature falls.
The flaps do not start swinging
immediately.
•
The air conditioner is adjusting the position of the flaps.
The flaps will start moving soon.
Different sounds are heard.
A sound like flowing water
•
This sound is generated because the refrigerant in the
air conditioner is flowing.
•
This is a pumping sound of the water in the air conditioner
and can be heard when the water is pumped out from the air
conditioner during COOL or DRY operation.
•
Refrigerant flows inside the air conditioner even when
one indoor unit is not in operation if the other indoor
unit is in operation.
Blowing sound
•
This sound is generated when the flow of the
refrigerant in the air conditioner is switched over.
Ticking sound
•
This sound is generated when the cabinet and frame
of the air conditioner slightly expand or shrink as a
result of temperature changes.
Whistling sound
•
This sound is generated when refrigerant flows during
defrosting operation.
Clicking sound during operation or idle time
•
This sound is generated when the refrigerant control
valves or the electrical parts operate.
Clopping sound
•
This sound is heard from the inside of the air
conditioner when the exhaust fan is activated while the
room doors are closed. Open the window or turn off
the exhaust fan.
Rotating machinery causes sound
•
Sound is heard when the vertical swing flaps and the
horizontal swing flaps move.
•
When the air conditioner is operating in a quiet environment
and the airflow rate of the indoor unit is set to Quiet Mode or
Low Mode, the motion of the swing flaps may cause sound.
The outdoor unit emits water or steam.
In HEAT operation
•
The frost on the outdoor unit melts into water or steam when the air
conditioner is in defrosting operation.
In COOL or DRY operation
•
Moisture in the air condenses into water on the cool surface of the outdoor
unit piping and drips.
* Appearance of the outdoor unit may
differ from some models.
Care
When the Need Arises
01_EN_3P683779-12A.indd 22
17/10/2022 15:00:17
Summary of Contents for FTXF20W2VMA
Page 28: ...27 MEMO 01_EN_3P683779 11A indd 27 17 10 2022 15 03 14...
Page 29: ...28 MEMO 01_EN_3P683779 11A indd 28 17 10 2022 15 03 14...
Page 30: ...29 MEMO 01_EN_3P683779 11A indd 29 17 10 2022 15 03 14...
Page 31: ...30 MEMO 01_EN_3P683779 11A indd 30 17 10 2022 15 03 14...
Page 60: ...27 MEMO 01_EN_3P683779 12A indd 27 17 10 2022 15 00 18...
Page 61: ...28 MEMO 01_EN_3P683779 12A indd 28 17 10 2022 15 00 18...
Page 62: ...29 MEMO 01_EN_3P683779 12A indd 29 17 10 2022 15 00 18...
Page 63: ...30 MEMO 01_EN_3P683779 12A indd 30 17 10 2022 15 00 18...