7 Technical data
Installation manual
10
FTXA25~50(A)(B)2V1B(W)(S)(T)(B)
Daikin room air conditioner
3P482320-7P – 2019.10
1
In cooling mode, select the lowest programmable temperature.
In heating mode, select the highest programmable temperature.
Test run can be disabled if necessary.
2
When the test run is finished, set the temperature to a normal
level. In cooling mode: 26~28°C, in heating mode: 20~24°C.
3
The system stops operating 3 minutes after the unit is turned
OFF.
6.2.1
To perform a test run using the user
interface
1
Press
to switch the system on.
2
Press
and
simultaneously.
3
Press
, select
and press
.
Result:
Test run operation will stop automatically after about
30 minutes.
4
To stop operation sooner, press
.
7
Technical data
▪ A
subset
of the latest technical data is available on the regional
Daikin website (publicly accessible).
▪ The
full set
of latest technical data is available on the Daikin
Business Portal (authentication required).
7.1
Wiring diagram
The wiring diagram is delivered with the unit, located inside of
the outdoor unit (bottom side of the top plate).
7.1.1
Unified wiring diagram legend
For applied parts and numbering, refer to the wiring diagram on the
unit. Part numbering is by Arabic numbers in ascending order for
each part and is represented in the overview below by "*" in the part
code.
Symbol
Meaning
Symbol
Meaning
Circuit breaker
Protective earth
Connection
Protective earth
(screw)
,
Connector
A
Rectifier
Earth
Relay connector
Field wiring
Short-circuit
connector
Fuse
Terminal
INDOOR
Indoor unit
Terminal strip
OUTDOOR
Outdoor unit
Wire clamp
Symbol
Colour
Symbol
Colour
BLK
Black
ORG
Orange
BLU
Blue
PNK
Pink
BRN
Brown
PRP, PPL
Purple
GRN
Green
RED
Red
GRY
Grey
WHT
White
YLW
Yellow
Symbol
Meaning
A*P
Printed circuit board
Symbol
Meaning
BS*
Pushbutton ON/OFF, operation
switch
BZ, H*C
Buzzer
C*
Capacitor
AC*, CN*, E*, HA*, HE*, HL*,
HN*, HR*, MR*_A, MR*_B, S*, U,
V, W, X*A, K*R_*
Connection, connector
D*, V*D
Diode
DB*
Diode bridge
DS*
DIP switch
E*H
Heater
FU*, F*U, (for characteristics,
refer to PCB inside your unit)
Fuse
FG*
Connector (frame ground)
H*
Harness
H*P, LED*, V*L
Pilot lamp, light emitting diode
HAP
Light emitting diode (service
monitor green)
HIGH VOLTAGE
High voltage
IES
Intelligent eye sensor
IPM*
Intelligent power module
K*R, KCR, KFR, KHuR, K*M
Magnetic relay
L
Live
L*
Coil
L*R
Reactor
M*
Stepper motor
M*C
Compressor motor
M*F
Fan motor
M*P
Drain pump motor
M*S
Swing motor
MR*, MRCW*, MRM*, MRN*
Magnetic relay
N
Neutral
n=*, N=*
Number of passes through ferrite
core
PAM
Pulse-amplitude modulation
PCB*
Printed circuit board
PM*
Power module
PS
Switching power supply
PTC*
PTC thermistor
Q*
Insulated gate bipolar transistor
(IGBT)
Q*DI
Earth leak circuit breaker
Q*L
Overload protector
Q*M
Thermo switch
R*
Resistor
R*T
Thermistor
RC
Receiver
S*C
Limit switch
S*L
Float switch
S*NPH
Pressure sensor (high)
S*NPL
Pressure sensor (low)
S*PH, HPS*
Pressure switch (high)
S*PL
Pressure switch (low)
S*T
Thermostat
S*RH
Humidity sensor
S*W, SW*
Operation switch
Summary of Contents for FTXA25BB/RXA25A
Page 1: ...Daikin Stylish FTXA25BB RXA25A...
Page 6: ......
Page 12: ......
Page 15: ...3P482320 7P 2019 10 Copyright 2017 Daikin...
Page 16: ......