English
4
Indoor Unit Installation Drawings
Intelligent-eye sensor (FTXS, FTX, FTKS only)
CAUTION
1) Do not hit or violently push the Intelligent-eye sensor. This can lead to damage and malfunction.
2) Do not place large objects near the sensor. Also keep heating units or humidifiers outside the sensor’s detection area.
M4 × 16L
M4 × 16L
30mm or more from ceiling
Front panel
50mm or more
from walls
(on both sides)
Intelligent-eye sensor
(FTXS, FTX, FTKS only)
Service lid
Opening service lid
Service lid is opening/closing type.
Opening method
1) Remove the service lid screws.
2) Pull out the service lid diagonally
down in the direction of the arrow.
3) Pull down.
Wrap the insulation pipe with
the finishing tape from bottom
to top.
Cut thermal insulation
pipe to an appropriate
length and wrap it with
tape, making sure that no
gap is left in the insulation
pipe’s cut line.
Caulk
pipe hole
gap
with putty.
The mounting plate
should be installed on a
wall which can support the
weight of the indoor unit.
D
E
Remote
controller
holder
Wireless
remote
controller
Before screwing the remote
controller holder to the wall, make
sure that control signals are
properly received by indoor unit.
B Titanium Apatite Photocatalytic
Air-Purifying Filter
Tabs (upper 3 locations)
Tabs (lower 3 locations)
Air filters
Insert the upper side of the Titanium Apatite
Photocatalytic Air-Purifying Filter into the tabs
(upper 3 locations), push the lower side of the filters
up a little and into the tabs (lower 3 locations).
B
How to attach the indoor unit.
Hook the claws of the bottom frame
to the mounting plate.
If the claws are difficult to hook,
remove the front grille.
How to remove the indoor unit.
Push up the marked area (at the
lower part of the front grille) to
release the claws. If it is difficult to
release, remove the front grille.
Front
grille
A Mounting
plate
Clip
Bottom frame
Mark (rear side)
Screws
(Field supply: M4 × 25L)
A
Mounting plate
Screws
(Field supply: M3 × 20L)
01_EN_3P190114-1D.fm Page 4 Monday, August 23, 2010 3:35 PM