Wall mounted unit providing high efficiency and comfort

Online controller (optional): control your indoor unit from any location 
via smartphone, laptop, pc, tablet or touch screen

3-D air flow combines vertical and horizontal auto swing to circulate 
a stream of warm or cool air right to the corners of even large spaces

Indoor unit silent operation: "silent" button on the remote control 
lowers the operation sound of the indoor unit by 3dBA

Outdoor unit silent operation: "silent" button on the remote control 
lowers the operation sound of the outdoor unit by 3dBA to ensure a 
quiet environment for the neighbourhood.

Home leave operation maintains the indoor temperature at your 
specified comfort level during absence, thus saving energy

Dry programme allows humidity levels to be reduced without 
variations in room temperature

Movement sensor saves power consumption in unoccupied rooms: 
when the room is empty, the unit switches to economy mode after 20 
minutes and restarts when a person enters the room.

Night set mode saves energy by preventing overcooling or 
overheating during night time

Movement 

sensor

Home leave 

operation

Night set mode

Fan only

Powerful mode Auto cooling-

heating 

changeover

Indoor unit 

silent operation

Outdoor unit 

silent operation

3-D air flow

Vertical auto 

swing

Horizontal auto 

swing

Auto fan speed

Fan speed 

steps

Dry programmeTitanium apatite 

photocatalytic 

air purification 

filter

24 hour timer Infrared remote 

control

Auto-restart

Self diagnosis

Summary of Contents for FTX50GV

Page 1: ...Air Conditioning Technical Data Wall mounted unit EEDEN15 100 FTX GV ...

Page 2: ......

Page 3: ...X GV 1 Features 2 2 Specifications 3 Technical Specifications 3 Electrical Specifications 4 3 Options 5 4 Dimensional drawings 6 5 Centre of gravity 7 6 Piping diagrams 8 7 Wiring diagrams 9 Wiring Diagrams Single Phase 9 8 Sound data 10 Sound Pressure Spectrum 10 ...

Page 4: ... environment for the neighbourhood Home leave operation maintains the indoor temperature at your specified comfort level during absence thus saving energy Dry programme allows humidity levels to be reduced without variations in room temperature Movement sensor saves power consumption in unoccupied rooms when the room is empty the unit switches to economy mode after 20 minutes and restarts when a p...

Page 5: ...2 14 6 cfm 519 572 516 Low m min 10 3 11 4 11 6 cfm 364 403 410 Silent operati on m min 9 5 10 2 10 6 cfm 335 360 374 Heating High m min 16 1 17 4 19 7 cfm 568 614 696 Nom m min 13 9 15 1 16 9 cfm 491 533 597 Low m min 11 5 12 7 14 3 cfm 406 448 505 Silent operati on m min 10 2 11 4 12 7 cfm 360 403 448 Fan motor Model ARW30W8P43DK D43F 31 Speed Steps 5 silent auto Cooling High Mediu m Low Silent ...

Page 6: ...Quantity 2 Notes 1 220V 2 230V 3 240V SL The silent fan level of the air flow rate setting Piping connections Liquid OD 6 35 Gas OD 12 7 15 9 Drain 18 Heat insulation Both liquid and gas pipes Temperature control Microcomputer control Air direction control Right Left Horizontal Downward 2 2 Electrical Specifications FTX50GV FTX60GV FTX71GV Power supply Name V1 Phase 1 Frequency Hz 50 Voltage V 220...

Page 7: ...3 3 Split Sky Air FTX GV 5 Indoor Unit FTX GV 3 Options 3 1 Options ...

Page 8: ...ance Min 30 Space for performance REQUIRED SPACE Air flow indoor For performance and maintenance shows piping direction Including installation plate FTX71GV 3D055876A The mark Left Rear Rear Right Space for maintenance Min 50 Model name plate Including installation plate Terminal block with earth terminal inside Wall hole for embedded piping ø 80 hole Infrared remote control Signal transmitter Fro...

Page 9: ...3 5 Split Sky Air FTX GV 7 Indoor Unit FTX GV 5 Centre of gravity 5 1 Centre of Gravity FTX50 71GV 4D065971B B B ...

Page 10: ... Indoor Unit FTX GV 6 Split Sky Air FTX GV 8 6 Piping diagrams 6 1 Piping Diagrams ...

Page 11: ...1 H3 Harness S1 S38 Connector H1P H3P Pilot lamp S1W Operation switch M1F Fan motor X1M Terminal strip M1S M2S Swing motor Protective earth LED1 LED2 LED3 RECTIFIER Transmission circuit Intelligent eye sensor Signal receiver Indoor infrared remote control Field wiring Outdoor CAUTION Note that operation will restart automatically if the main power supply is turned off and then back on again U ...

Page 12: ...ready rectified 2 Measuring place measure in anechoic room 3 Operation noise differs with operation and ambient conditions 4 Location of microphone JISC9612 The operation noise measuring method is in accordance with JISC9612 Octave band sound pressure level dB 0 dB 0 0002μ bar Octave band sound pressure level dB 0 dB 0 0002μ bar Octave band center frequency IEC Hz Octave band center frequency IEC ...

Page 13: ...N is already rectified 2 Measuring place measure in anechoic room 3 Operation noise differs with operation and ambient conditions 4 Location of microphone JISC9612 The operation noise measuring method is in accordance with JISC9612 Octave band sound pressure level dB 0 dB 0 0002μ bar Octave band sound pressure level dB 0 dB 0 0002μ bar Octave band center frequency IEC Hz Octave band center frequen...

Page 14: ......

Page 15: ...kin Europe N V has compiled the content of this leaflet to the best of its knowledge No express or implied warranty is given for the completeness accuracy re liability or fitness for particular purpose of its content and the products and services presented therein Specifications are subject to change without prior notice Daikin Europe N V explicitly rejects any liability for any direct or indirect...

Reviews: