SiENBE12-713
Specifications
Specifications
23
1.2
Outdoor Units - Cooling Only
50Hz 230V
Note:
1. The data are based on the conditions shown in the table below.
Model
4MKS75F2V1B
Cooling Capacity
kW
—
Power Consumption
W
—
Running Current
A
—
Casing Color
Ivory White
Compressor
Type
Hermetically Sealed Swing Type
Model
2YC45DXD
Motor Output
W
1,380
Refrigerant Oil
Model
FVC50K
Charge
L
0.65
Refrigerant
Type
R-410A
Charge
kg
2.3
Air Flow Rates
m³/min
H
52.7
M
49.4
L
43.5
cfm
H
1,861
M
1,744
L
1,536
Fan
Type
Propeller
Motor Output
W
53
Running Current
A
H: 0.20 / M: 0.16 / L: 0.10
Power Consumption
W
H: 70 / M: 58 / L: 36
Starting Current
A
6.2
Dimensions (H×W×D)
mm
735×936×300
Packaged Dimensions (H×W×D)
mm
797×992×390
Weight
kg
57
Gross Weight
kg
61
Operation Sound
dBA
48
Sound Power
dBA
61
Piping Connection
Liquid
mm
φ
6.4×4
Gas
mm
φ
9.5×2,
φ
12.7×1,
φ
15.9×1
Drain
mm
φ
18.0
Heat Insulation
Both Liquid and Gas Pipes
No. of Wiring Connection
3 for Power Supply, 4 for Interunit Wiring
Max. Interunit Piping Length
m
60 (for Total of Each Room)
m
25 (for One Room)
Amount of Additional Charge
g/m
Chargeless
Max. Installation Height Difference
m
15 (between Indoor Unit and Outdoor Unit)
m
15 (between Indoor Units)
Drawing No.
3D056453
Conversion Formulae
kcal/h=kW×860
Btu/h=kW×3414
cfm=m³/min×35.3
Cooling
Piping Length
Indoor ; 27°CDB/19°CWB
Outdoor ; 35°CDB
5m
Summary of Contents for FTKS20D3VMW
Page 11: ...Introduction SiENBE12 713 x...
Page 47: ...Specifications SiENBE12 713 36 Specifications...
Page 113: ...Control Specification SiENBE12 713 102 Function and Control...
Page 235: ...Instruction SiENBE12 713 224 System Configuration...
Page 297: ...Check SiENBE12 713 286 Service Diagnosis...
Page 316: ...SiENBE12 713 Outdoor Unit Removal Procedure 305 Step Procedure Points...