background image

14

HOME LEAVE Operation

1 Every day before you leave the house...

Useful at times like these!

2 Before bed...

When you go out, push the
“HOME LEAVE Operation”
button, and the air
conditioner will adjust
capacity to reach the
preset temperature for
HOME LEAVE Operation.

When you return, you will
be welcomed by a
comfortably air conditioned
room.

Push the “HOME LEAVE
Operation” button again,
and the air conditioner will
adjust capacity to the set
temperature for normal
operation.

Set the unit to HOME
LEAVE Operation before
leaving the living room
when going to bed.

The unit will maintain the
temperature in the room at
a comfortable level while
you sleep.

When you enter the living room in
the morning, the temperature will
be just right.
Disengaging HOME LEAVE
Operation will return the
temperature to that set for normal
operation. Even the coldest
winters will pose no problem!

NOTE

<Note on HOME LEAVE Operation>

 HOME LEAVE Operation is only available in COOL and HEAT modes. (Cannot be used in AUTO, DRY, and FAN

modes.)

 HOME LEAVE Operation runs in accordance with the operation mode the unit was in before using HOME LEAVE

Operation.

 HOME LEAVE Operation can be set within the ranges shown below.

Temperature: (During heating) 10°C to 30°C

(During cooling) 18°C to 32°C

Air flow rate: 5 steps from weak to strong, or automatic.

 Using POWERFUL operation (P12) during HOME LEAVE Operation will disengage HOME LEAVE Operation.

 Turning the unit off by flipping the switch on the unit during HOME LEAVE Operation will shut the unit off. The unit

will continue in HOME LEAVE Operation when turned back on.

 Turning the unit off with the remote control during HOME LEAVE Operation will shut the unit off.

H/P: HOME LEAVE Operation will be disengaged when the unit is turned back on.
C/O: HOME LEAVE Operation will continue when the unit is turned back on.

Summary of Contents for FTKD

Page 1: ...ting the vertical blade louvre 11 POWERFUL Operation 12 OUTDOOR UNIT SILENT Operation 12 HOME LEAVE Operation 13 Timer Operation OFF TIMER operation 15 ON TIMER operation 15 CARE Care and Cleaning Cle...

Page 2: ...he supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Do not use the air conditioner for preservation purpos...

Page 3: ...ine to a gas pipe water pipe lightening rod or a telephone earth line WARNING CAUTION Installation Do not place under the indoor or outdoor unit anything which must be kept away from moisture Indoor u...

Page 4: ...l automatically start and operate in the mode in which a previously operated indoor unit was stopped However if the unit in operation provides only COOL and DRY modes simultaneous operation is possibl...

Page 5: ...is on the fan may rotate inside and may cause injury CAUTION Receiver FTKD COOL Mode 22 C Temperature setting AUTO FTXD AUTO 25 C AUTO Air flow rate DAIKIN Front grille Indicator lamps Grille tab Dif...

Page 6: ...etting button It selects the air flow rate setting SWING buttons See page 11 It changes the temperature or time setting Display It displays the current settings In this illustration each section is sh...

Page 7: ...r unit Names of Parts Air inlet Air outlet Back and side Refrigerant piping and inter unit cable Earth terminal It is inside of this part Drain hose Appearance of the outdoor unit may differ with some...

Page 8: ...aximum distance for communication is about 7 m To remove pull it upwards ATTENTION Remote controller holder Set Push 1 2 To fix the remote controller holder on the wall Choose a place from where the s...

Page 9: ...mple in spring or autumn turn the breaker OFF Use the air conditioner in the following conditions Press blinks Now the clock is set Mode COOL HEAT DRY Operating conditions Outdoor temperature 5 to 46...

Page 10: ...NOTE Note on HEAT mode operation Since this air conditioner heats the room by taking heat from outdoor air to indoors the heating capacity becomes smaller in lower outdoor temperatures If the heating...

Page 11: ...when it is swinging the mechanism may be broken Notes on flap angles Adjusting the vertical blade louvre Press Every time the button is pressed appears or disappears The louvre automatically swings ri...

Page 12: ...ature setting is lowered by 3 C and the air flow rate is slightly increased In FAN mode The air flow rate is fixed to the maximum setting OUTDOOR UNIT SILENT operation lowers the noise level of the ou...

Page 13: ...2 3 Adjust the air flow rate setting with FAN as you like The temperature and air flow rate will be the same as the previous settings starting with the second use If you want to change the settings fr...

Page 14: ...l operation Even the coldest winters will pose no problem NOTE Note on HOME LEAVE Operation HOME LEAVE Operation is only available in COOL and HEAT modes Cannot be used in AUTO DRY and FAN modes HOME...

Page 15: ...1 Notes on OFF TIMER ON TIMER operation Press ON TIMER while the air conditioner is not operating Press ON TIMER once again Check that the clock is correct If not set the clock to the present time See...

Page 16: ...filters Wipe them with dry soft cloth For cleaning do not use water hotter than 40 C benzine gasoline thinner nor other volatile oils polishing compound scrubbing brushes nor other hard stuff It is re...

Page 17: ...e front grille with one hand fit the lock by sliding up the knob with the other hand Close the front grille slowly in this state Push the grille at the 3 points two at both sides and in the middle Ope...

Page 18: ...e system is taking away the frost on the outdoor unit You should wait for about 3 to 10 minutes In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defr...

Page 19: ...air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the breaker OFF Then turn it ON again and try operating the air conditioner with t...

Page 20: ...or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and call...

Reviews: