FT50GAVAL
FTY50GAVAL
FT60GAVAL
FTY60GAVAL
MODELS
DAIKIN ROOM AIR CONDITIONER
Operation Manual
ENGLISH
PORTUGUES
ESPAÑOL
Page 1: ...FT50GAVAL FTY50GAVAL FT60GAVAL FTY60GAVAL MODELS DAIKIN ROOM AIR CONDITIONER Operation Manual ENGLISH PORTUGUES ESPA OL...
Page 2: ...blade flap 10 Adjusting the vertical blade louvre 10 POWERFUL Operation 11 Timer Operation OFF TIMER operation 12 ON TIMER operation 12 CARE Care and Cleaning Cleaning the air filters 13 Cleaning the...
Page 3: ...ight accompany addition of refrigerant The refrigerant used in the air conditioner is safe Although leaks should not occur if for some reason any refrigerant happens to leak into the room make sure it...
Page 4: ...the unit or a qualified technician The air conditioner must be earthed Incomplete earthing may result in electric shocks Do not connect the earth line to a gas pipe water pipe lightening rod or a tel...
Page 5: ...must be discharged to a place of good drainage Installation site For installation choose a place as described below A place solid enough to bear the weight of the unit which does not amplify the opera...
Page 6: ...ON Receiver FT COOL Mode 22 C Temperature setting AUTO FTY AUTO 25 C AUTO Air flow rate Control panel Cleaning lamp reset button Push this button to turn the CLEANING lamp off DAIKIN Front grille Indi...
Page 7: ...w rate setting SWING buttons See page 10 It changes the temperature or time setting Display It displays the current settings In this illustration each section is shown with all its displays ON for the...
Page 8: ...t drop the remote controller Do not get it wet The maximum distance for communication is about 7 m ATTENTION Remote controller holder Set Push 1 2 To fix the remote controller holder on the wall Choos...
Page 9: ...C Indoor temperature 28 C max Outdoor temperature 19 to 54 C Indoor temperature 18 to 32 C Indoor humidity 80 max If operation is continued out of this range A safety device may work to stop the opera...
Page 10: ...r conditioner heats the room by taking heat from outdoor air to indoors the heating capacity becomes smaller in lower outdoor temperatures If the heating effect is insufficient it is recommended to us...
Page 11: ...m the display of remote controller DRY COOL FAN HEAT ATTENTION Always use a remote controller to adjust the flap angle If you attempt to move it forcibly with hand when it is swinging the mechanism ma...
Page 12: ...ration During you use POWERFUL operation the other functions will not go on Press To cancel POWERFUL operation POWERFUL Operation 1 Press Notes on POWERFUL operation In COOL and HEAT mode To maximize...
Page 13: ...et the clock to the present time See page 8 NIGHT SET MODE When the OFF TIMER is set the air conditioner automatically adjusts the temperature setting 0 5 C up in COOL 2 0 C down in HEAT to prevent ex...
Page 14: ...ilters Item Air purifying filter with frame Air purifying filter without frame Part No KAF918A41 KAF918A42 4 Push Before cleaning be sure to stop the operation and turn the breaker OFF It is recommend...
Page 15: ...tuff After cleaning make sure that the front grille is securely fixed 1 3 2 4 Attach the front grille Set the 3 keys of the front grille into the slots and push them in all the way Supporting the fron...
Page 16: ...system is taking away the frost on the outdoor unit You should wait for about 3 to 10 minutes In HEAT mode The frost on the outdoor unit melts into water or steam when the air conditioner is in defro...
Page 17: ...d the outdoor units Is the temperature setting appropriate Are the windows and doors closed Are the air flow rate and the air direction set appropriately Are the air filters clean Is there anything to...
Page 18: ...use or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell Water leaks from the indoor unit Turn the breaker OFF and...