General safety precautions

Installation and operating instructions

4

Daikin FLOSTO150

Hot water storage tank

008.1632099_00 – 03/2019 – EN

1

General safety precautions

1.1

Particular safety instructions

WARNING

Devices that have not been set up and
installed correctly can impair the func-
tion of the device and/or cause serious
or fatal injury to the user.

▪ Work on the device (such as set-up,

servicing, connection and initial com-
missioning) must only be carried out
by persons who are authorised who
are authorised and who have suc-
cessfully completed 

qualifying tech-

nical or vocational training

 and

who have taken part in advanced
training sessions recognised by the
relevant responsible authorities for
the specific activity. These include,
in particular, 

certified heating en-

gineers, qualified electricians and
HVAC specialists

, who, because of

their 

professional training 

and their

expert knowledge,

 have experience

in the professional installation and
maintenance of heating systems,
gas installations and hot water tanks.

WARNING

Disregarding the following safety in-
structions may result in serious phys-
ical injury or death.

▪ This device must only be used by

children

 aged 8 and above and by

persons with restricted physical,
sensory or mental capabilities or with
a lack of experience and knowledge,
if they are under supervision or if
they have been instructed in the safe
use of the equipment and under-
stand the dangers arising therefrom.

Children

 must not play with the

device. Cleaning and 

user mainten-

ance

 must not be carried out by

children

 without supervision.

▪ Make up the power supply in accord-

ance with IEC 60335-1, via a separ-
ator device which exhibits contact
separation in all poles with a contact
opening distance that provides full
disconnection in accordance with
overvoltage category III.

▪ All the electrical work must only be

carried out by electrically qualified
experts and with consideration of the
local and national regulations, and
the instructions in these operating in-
structions.
Check that a suitable electrical cir-
cuit is being used.
Inadequate capacity of the power cir-
cuit or improperly executed connec-
tions can cause electrocution or fire.

▪ The customer must install a pressure

relief device with rated over-pressure
less than 0.6 MPa (6 bar). The con-
nected drain line must have a con-
tinuous gradient and a free outlet in
a frost-free environment
(see 

Chap. 4.1

).

▪ Water may drip out of the drain line

of the pressure relief device. The
drain opening must be left free to at-
mosphere.

▪ The pressure relief device must be

operated regularly in order to re-
move scale deposits and to make
sure it is not blocked.

▪ The storage tank and hot water cir-

cuit can be drained. The instructions
in 

Chap. 6.1

 must be observed.

1.1.1

Observing the instructions

▪ The original documentation is written in German. All other lan-

guages are translations.

▪ Please read these instructions carefully and thoroughly before

starting with the installation or modification of the heating system.

▪ The precautionary measures described in this document cover

very important topics. Follow them meticulously.

▪ The installation of the system, and all activities described in these

instructions and the applicable documents for the installer must be
carried out by an approved installer.

Summary of Contents for FLOSTO150

Page 1: ...Installation and operating instructions Hot water storage tank English Installation and operating instructions FLOSTO150 03 2019...

Page 2: ......

Page 3: ...sion heater 9 3 2 2 Circulation brakes 9 3 2 3 Scalding protection 9 3 2 4 Circulation line connection 9 3 2 5 External current anode 9 3 2 6 Storage tank connection kit 9 4 Set up and installation 10...

Page 4: ...t by children without supervision Make up the power supply in accord ance with IEC 60335 1 via a separ ator device which exhibits contact separation in all poles with a contact opening distance that p...

Page 5: ...rform the respective activity and who have participated in advanced training courses re cognised by the relevant competent authority These in clude in particular certified heating engineers quali fied...

Page 6: ...culated as calcium carbonate 3 mmol l Conductivity 1500 ideal 100 S cm Chloride 250 mg l Sulphate 250 mg l pH value heating water 6 5 8 5 Measures for desalination softening or hardness stabilisation...

Page 7: ...s and operating manual to the operator and point out that these documents must be made available at all times and must be stored in the immediate vicinity of the device Document the handover by fillin...

Page 8: ...tion Installation and operating instructions 8 Daikin FLOSTO150 Hot water storage tank 008 1632099_00 03 2019 EN 3 Product description 3 1 Design and components Fig 3 1 View from front Fig 3 2 View fr...

Page 9: ...n brakes To prevent heat loss from the connection pipes when the circulation pump is switched off and during periods when no domestic water is drawn off gravity circulation circulation brakes ZKB set...

Page 10: ...device If there are any questions please contact our Technical Customer Service 4 1 2 Scope of delivery E F Fig 4 1 Scope of delivery Item Designation A Storage tank cladding side panel B Storage tan...

Page 11: ...FLOSTO150 Hot water storage tank 008 1632099_00 03 2019 EN Fig 4 3 Installing the hot water storage tank 4 1 4 Mounting removing the storage tank cladding Mounting the storage tank cladding Fig 4 4 In...

Page 12: ...ccur when legionella protection is active or when the hot water target temperature is set to 60 C Fit scalding protection see Chap 3 2 3 For domestic water pipes observe the stipulations of EN 806 and...

Page 13: ...loss Install the heat insulation in accordance with country specific guidelines The manufacturer recommends an insulation thickness of at least 20 mm 4 3 Filling Topping Up INFORMATION Any optional ac...

Page 14: ...is an electric immersion heater set the required storage water temperature Switch on the mains supply switch on the heat generator Wait for the start phase Only if all points on the checklist can be a...

Page 15: ...Open all water outlets 3 Connect the drain hose to the combined filling and draining valve of the storage tank 4 Open the combined filling and draining valve Fig 6 1 Draining the storage tank 6 2 1 D...

Page 16: ...ment H 1 H 2 H m Heating circuits MAG Diaphragm expansion vessel MIX 3 way mixer with drive motor MK1 Mixer group with high efficiency pump MK2 Mixer group with high efficiency pump PWM regu lated P K...

Page 17: ...ter storage tank 008 1632099_00 03 2019 EN PK SV MAG A2 F Flosto tV1 tR MIX H2 PMI tMI tAU M RoCon M1 H1 MK1 MK2 DHW VS tDHW DS SV CW F B n o C o R M A B AB 3UV DHW 3UVB1 FLS M B A AB tV2 Fig 7 2 Conn...

Page 18: ...ating specialists authorised and recog nised by the energy supply company 8 1 Annual inspection If present Carry out a functional inspection of the electric immersion heater by checking the temperatur...

Page 19: ...from the tank with the narrow side ahead Make sure that no parts can fall into the tank If necessary secure the lid with a cord Fig 8 4 Checking and cleaning the interior of the storage tank 6 Check a...

Page 20: ...tinuous output QD according to DIN 4708 kW 49 Maximum draw off rate for the duration of 10 min on recharging at xx kW TkW 10 C TWW 40 C TSP 60 C l min 20 1 Hot water volume without reheating at a draw...

Page 21: ...illibars m l h Flow rate in litres per hour m l min Flow rate in litres per minute Storage tank charging heat exchanger 1 9 3 Tightening torques Designation Thread size Tightening torque Hydraulic lin...

Page 22: ...10 Notes Installation and operating instructions 22 Daikin FLOSTO150 Hot water storage tank 008 1632099_00 03 2019 EN 10 Notes...

Page 23: ...osal 15 Domestic water pipes 12 Draining the heating circuit 15 E Electric immersion heater 9 14 Electrical installation 6 External current anode 9 I Inspection 18 Installing the hot water storage tan...

Page 24: ...008 1632099_00 03 2019 EN Copyright Daikin...

Reviews: