background image

9  Drain piping 

10  Refrigerant piping 

11 

Transmission wiring 

Earth wiring 

(NOTE) 

12 

It is wiring to let electricity flow from the indoor unit to 

the earth for prevention of electric shocks / a fire in 

case of emergency. 

Indoor unit model nameplate (inside suction grille) 

13 

Lists the indoor unit model name and other related 

information. 

14 

Decoration panel model nameplate (inside suction 

grille) 

Lists the decoration panel model name and other 

related information. 

(*1) With an installed sensor kit (optional accessory) 

3. OPERATION RANGE

If the temperature or the humidity is beyond the  following 

conditions, safety devices may work and  the air conditioner 

may not operate, or sometimes, water may drop from the 

indoor unit. 

COOLING 

[

O

C] 

OUTDOOR 

INDOOR 

OUTDOOR 

UNIT 

TEMPERATURE  HUMIDITY TEMPERATURE 

RZVFS0 

DB 

21 to 37  80%* or

DB 

21 to 46 

RZVF71 

WB 

14 to 28  below 

* To avoid condensation and water dripping out the indoor unit.

DB:  Dry bulb temperature

WB: Wet bulb temperature

The setting temperature range of the remote controller is as

follows.

Cooling operation: 16 to 32

°

C

4. INSTALLATION SITE

Regarding places for installation 

• Is the air conditioner installed at a well-ventilated

place where there are no obstacles around?

• Do not use the air conditioner in the following places.

a. Filled with much mineral oil such as cutting oil

b.  Where there is much salt such as a beach area

c. Where sulfured gas exists such as a hot-spring resort

d. Where there are considerable voltage fluctuations

such as a factory or plant

e. Vehicles and vessels

f. Where there is much spray of oil and vapor such as a

cookery, etc.

g. Where there are machines generating electromagnetic

waves

h. Filled with acid and/or alkaline steam or vapor

• Is a snow protection measure taken?

For details, consult your dealer about snow protection

hoods, etc.

Regarding wiring 

• All wiring must be performed by an authorized

electrician.

To do wiring, ask your dealer. Never do it by yourself.

• Make sure that a separate power supply circuit is

provided for this air conditioner and that all electrical

work is carried out by qualified personnel according

to local laws and regulations.

Pay attention to running noises, too 

• Are the following places selected?

a. A place that can sufficiently withstand the weight of the

air conditioner with less running noises and vibrations.

b.  A place where the hot wind discharged from the air

outlet of the outdoor unit and the running noises do

not cause a nuisance to neighbours.

• Are you sure that there are no obstacles near the air

outlet of the outdoor unit?

Such obstacles may result in declined performance and

increased running noises.

• If abnormal noises occur in use, stop the operation

of the air conditioner, consult your dealer.

System relocation 

• Consult your Daikin dealer about remodelling and 

relocation.

Regarding drainage of drain pipe 

• Is the drain pipe executed to perform complete

drainage?

If proper drainage is not carried out from the outdoor drain

pipes during air-conditioning operation, chances are that

dust and dirt are clogged in the pipe.  This may result in a

water leakage from the indoor unit. Under such

circumstances, stop the operation of the air conditioner,

and then consult your dealer or our service station.

5. OPERATION PROCEDURE

• Operation procedure

Read the operation manual attached to the remote

controller.

• Operation procedure varies with heat pump type and

cooling only type. Contact your local  dealer to confirm

your system type.

• To protect the unit, turn on the main power supply switch

6 hours before operation.

• Do not shut off the power supply during seasonal use of

the air conditioner.

This is required in order to activate the air conditioner

smoothly.

• If the main power supply switch is turned off during

operation, operation will restart automatically after the

power turns back on again.

6.OPERA TION CHARACTERISTICS

■ CHARACTERISTICS OF THE COOLING OPERATION

{COOLING OPERATION AND AUTOMATIC

COOLING OPERATION)

• When operating continuously at downward airflow

direction, air blows in the automatically set direction

for a period of time to prevent condensation on the

horizontal blade.  (The remote controller displays the

airflow direction that is set.)

• If the COOLING OPERATION is used when the indoor

temperature is low, frost forms on the heat exchanger

of the indoor unit.  This can decrease the cooling capacity.

• When the outdoor temperature is high, it takes some time

until the indoor temperature reaches the set temperature.

■ CHARACTERISTICS OF THE  PROGRAM DRY

OPERATION

• This operation lowers the humidity without lowering the

indoor temperature.  The indoor temperature, when the

operation button is pressed,will be the set temperature.

At this time, the fan speed and temperature are set

automatically, so the remote controller does not display

the fan speed and set temperature.

To efficiently lower the indoor temperature and humidity,

first use the COOLING OPERATION to lower the indoor

21

Summary of Contents for FKCA50AV16

Page 1: ...TION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling Mounted Cassette type Single Flow model FKCA50AV16 FKCA71AV16 CAREFULLY READ THESE INSTRUCTIONS BEFORE INSTALLATION KEEP THIS MANUAL IN A HANDY...

Page 2: ...2...

Page 3: ...3...

Page 4: ...installation manual Paper board for ceiling opening within the box Accessories 4...

Page 5: ...5...

Page 6: ...6...

Page 7: ...7...

Page 8: ...8...

Page 9: ...9...

Page 10: ...9 3 Electrical characteristics 10...

Page 11: ...11...

Page 12: ...12...

Page 13: ...10 6 Panel wire connecting 13...

Page 14: ...14...

Page 15: ...15...

Page 16: ...I 3P725894 1 I DAIKIN OPERATION MANUAL SPLIT SYSTEM Air Conditioners MODELS Ceiling Mounted Cassette type Single Flow model FKCA50AV16 FKCA71AV16...

Page 17: ...onic products shall not be mixed with unsorted house hold waste Do not try to dismantle the system yourself the dismantling of the air conditioning system treatment of the refrigerant of oil and of ot...

Page 18: ...GUARANTEE 18...

Page 19: ...case of refrigerant leakage When the air conditioner is installed in a small room it is necessary to take proper measures so that the amount of any leaked refrigerant does not exceed the concentratio...

Page 20: ...eless remote controller kit If your installation has a customized control system ask your local dealer for the operation that corresponds to your system Cooling only type This system provides COOLING...

Page 21: ...from the air outlet of the outdoor unit and the running noises do not cause a nuisance to neighbours Are you sure that there are no obstacles near the air outlet of the outdoor unit Such obstacles ma...

Page 22: ...8 MAINTENANCE 22...

Page 23: ...9 AFTER SALES SERVICE AND GUARANTEE REPAIR After opening the suction grille remove the air lter as shown in the gure below 23...

Page 24: ...change the fan speed During the COOLING OPERATION the low fan speed or a gentle wind is used to prevent the discharge of melt water 4 THE AIRFLOW DIRECTION IS DIFFERENT FROM THE SETTING OR THE AIRFLO...

Page 25: ...the air outlet Refer to 8 MAINTENANCE on pages 2 Check if the set temperature is not proper Set to an appropriate temperature fan speed and discharge direction Check if the FAN SPEED button is set to...

Page 26: ...DAIKINAIRCONDITIONING IND A PVT LTD 12th Floor Building No 9 Tower A DLF Cyber City DLF Phase Ill Gurugram 122002 Haryana India I 3P725894 1...

Reviews: