ROUBLESHOOTING

If one of the following malfunctions occurs, take the measures shown
below and contact your Daikin dealer.

The system must be repaired by a qualified service person.

If a safety device such as a fuse, a breaker, or an earth leakage
breaker frequently actuates, or ON/OFF switch does not
properly work.
Measure: Turn off the main power switch.

If water leaks from unit.
Measure: Stop the operation.

If the display "

" (INSPECTION), "

", and the

OPERATION lamp flashes and the "MALFUNCTION CODE"
appears.
Measure: Notify your Daikin dealer and inform him/her of the
display.

If the system does not operate properly, except for the above
mentioned case, and none of the above mentioned malfunctions are
evident, investigate the system according to the following procedures.

If the system does not operate at all.

Check if there is a power failure.
Wait until power is restored. If power failure occurs during
operation, the system automatically restarts immediately after
the power supply recovers.

Check if the fuse has blown or breaker has been tripped.
Change the fuse or set the breaker.

If the system stops operating after operation is complete.

Check if the air inlet or outlet of outdoor or indoor unit is blocked
by obstacles.
Remove the obstacle and make it well-ventilated.

Check if the air filter is clogged.
Ask a qualified service person to clean the air filter.

The system operates but it does not sufficiently cool or heat.

If the air inlet or outlet of the indoor or the outdoor unit is blocked
with obstacles.
Remove the obstacle and make it well-ventilated.

If the air filter is clogged.
Ask a qualified service person to clean the air filter.

If the set temperature is not proper. (Refer to the manual of the
remote controller)

If the FAN SPEED CONTROL button is set to LOW SPEED.
(Refer to the manual of the remote controller)

If the air flow angle is not proper. (Refer to the manual of the
remote controller)

If the doors or the windows are open. Shut doors or windows to
prevent wind from coming in.

If direct sunlight enters the room (when cooling).
Use curtains or blinds.

When there are too many inhabitants in the room. Cooling effect
decreases if heat gain of the room is too large.

If the heat source of the room is excessive (when cooling).
Cooling effect decreases if heat gain of the room is too large.

M

AINTENANCE

WARNING

When the air conditioner is in abnormal conditions (burning
smell, etc.) unplug the power cord from the outlet and
contact your dealer.

Continued operation under such circumstances may result
in a failure, electric shock and fire.

Caution

Only a qualified service person is allowed to perform
maintenance.

Before obtaining access to terminal devices, all power
supply circuits must be interrupted.

To clean the air conditioner, be sure to stop operation
and turn the power switch off.
Otherwise, an electric shock and injury may result.

Do not wash the air conditioner with water.
Doing so may result in an electric shock.

Be careful with scaffoldings.
Caution must be exercised when working in high
places.

After a long use, check the unit stand and fitting for
damage. If damaged, the unit may fall and cause
injury.

Do not touch the heat exchanger fins.
The fins are sharp and could result in cutting injuries.

When cleaning the heat exchanger, be sure to remove
the switchbox, fan motor, auxiliary electric heater and
drain pump. Water or detergent may deteriorate the
insulation of electronic components and result in
burn-out of these components.

Caution for drain socket

Do not remove the drain pipe plug. Water might leak out.

The drain outlet is only used to discharge water if the drain
pump is not used or before maintenance. Gently put in and
out the drain plug. Excessive force may deform the drain
socket of the drain pan.

Pulling out the plug 

Do not wiggle the plug up and down

Pushing in the plug

Set the plug and push it by using a Philips screwdriver

1

1

Drain plug

1

2

1

Drain plug

2

Philips screwdriver

Summary of Contents for FHYBP35B7V1

Page 1: ...0B7V1 FBQ71B7V3B FBQ100B7V3B FBQ125B7V3B FCQ35B7V1 FCQ50B7V1 FCQ60B7V1 FCQ71B7V3B FCQ100B7V3B FCQ125B7V3B FDQ125B7V3B FDQ200B7V3B FDQ250B7V3B FHYBP71B8V1 FHYBP100B8V1 FHYBP125B8V1 FHYCP71B8V1 FHYCP100...

Page 2: ...10 30 10 30 10 27 RXS35 50 60 4MXS68 80 RZQ71 100 125 140 RP200 250 RR71 100 125 R35 45 60 RS50 60 RKS35 50 60 RXS35 50 60 3MKS50 4MKS58 75 90 3MXS52 3MXS52 4MXS68 80 80 80 80 80 80 80 5 43 5 43 10 46...

Page 3: ...ith remote controller 2 Unit without remote controller When used as simultaneous operation It is not good for your health to expose your body to the direct air flow for a long time In order to avoid e...

Page 4: ...er to Maintenance on page 4 When the display shows TIME TO CLEAN AIR FILTER have a qualified service person to clean the filters Refer to Maintenance on page 4 NOTE These units can be controlled by a...

Page 5: ...set temperature in heating mode the capacity supply from the outdoor unit has stopped and the indoor unit operates in fan only mode L tab In case of multi split the indoor unit alternately operates fa...

Page 6: ...oller If the air flow angle is not proper Refer to the manual of the remote controller If the doors or the windows are open Shut doors or windows to prevent wind from coming in If direct sunlight ente...

Page 7: ...air inlet grille Only for bottom suction 6 After turning on the power press FILTER SIGN RESET button The TIME TO CLEAN AIR FILTER display is turned off For FDYP and FDQ units See figure 5 1 Remove th...

Page 8: ...ower switch at least 6 hours before operation What to do when stopping the system for a long period Turn on FAN OPERATION for a half day and dry the unit Refer to the manual of the remote controller C...

Page 9: ...NOTES NOTES...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN10622 1E...

Reviews: