FHYBP + FHYCP + FDYP + FBQ + FCQ + FDQ
Split system air conditioners
4PW10622-1E

Operation manual

 

3

 

N

 

OT

 

 

 

A

 

 

 

MALFUNCTION

 

 

 

OF

 

 

 

THE

 

 

 

AIR

 

 

 

CONDITIONER

 

The following symptoms do not indicate air conditioner malfunction.

 

The system does not operate

 

 

The system does not restart immediately after the ON/OFF
button is pressed.
If the OPERATION lamp lights, the system is in its normal
operating condition.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded.
The system will turn on again automatically after three minutes.

 

 

The system does not restart immediately when the
TEMPERATURE SETTING button is returned to its former
position after pushing.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded.
The system will turn on again automatically after three minutes.

 

 

The system does not start when the display shows "

"

(EXTERNAL CONTROL ICON) and it flashes for a few seconds
after pressing an operation button.
This is because the system is controlled or disabled by another
controller with a higher priority.
When the display flashes, it indicates that the system cannot be
controlled by this indoor unit.

 

 

The system does not start immediately after the power supply is
turned on.
Wait one minute until the micro computer is prepared for
operation.

 

 

The outdoor unit has stopped.
This is because the room temperature has reached the set
temperature. The unit switches to fan operation.

"

"  (EXTERNAL CONTROL ICON) is displayed on the

remote controller and the actual operation is different from the
remote controller setting.
For multi split models, the micro computer executes the following
control depending on the operation mode of other indoor units.
-

Before you start to operate, the other indoor unit(s) is (are) 
already operating. When the operation mode of this unit is 
different from your choice, the indoor unit of your room may 
be put in waiting condition. (Fan: Stop, Horizontal flap: 
Horizontal position)

-

When the total cooling capacity of all indoor units which are 
operating is beyond the capacity limit of the outdoor unit, 
your indoor unit will be put in waiting condition. (Fan and 
horizontal flap: Same as setting: (cooling only model only))

-

After cooling mode operation of the unit of your room, when 
other unit(s) start to operate, the unit of your room may 
operate as follows: Fan: L tab, Horizontal flap: Horizontal 
position.

 

 

The fan speed is different from the setting. Pressing the fan
speed contol button does not change the fan speed.
When the room temperature reaches the set temperature in
heating mode, the capacity supply from the outdoor unit has
stopped and the indoor unit operates in fan only mode (L tab). In
case of multi split, the indoor unit alternately operates fan stop
and fan only mode (L tab).
This is to prevent the cool air from being blown directly onto
anyone present in the room.

 

Air blow direction is not as specified

 

 

Actual air blow direction is not as shown on the remote
controller.

 

 

Automatic swing setting does not work. 

Refer to the manual of the remote controller.

 

White mist comes out of a unit

 

 

When humidity is high during cooling operation (In oily or dusty
places).
If the inside of an indoor unit is extremely contaminated, the
temperature distribution inside a room becomes uneven. It is
necessary to clean the inside of the indoor unit. Ask your Daikin
dealer for details on cleaning the unit. This operation requires a
qualified service person.

 

 

When the system is changed over to HEATING OPERATION
after DEFROST OPERATION.
Moisture generated by DEFROST becomes steam and exits.

 

Noise of air conditioners

 

 

A "ringing" sound is heard after the unit is started.
This sound is generated by the temperature regulator working. It
will quiet down after about a minute.

 

 

A continuous low "hissing" sound is heard when the system is in
COOLING or DEFROST OPERATION.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.

 

 

A "hissing" sound which is heard at the start or immediately after
the stop of operation or which is heard at the start or
immediately after the stop of DEFROST OPERATION.
This is the noise of refrigerant caused by flow stop and flow
change.

 

 

A continuous low "swishing" sound is heard when the system is
in COOLING OPERATION or at a stop.
The noise is heard when the drain pump is in operation.

 

 

A "squeaking" sound is heard when the system is in operation or
after the stop of operation.
Expansion and contraction of plastic parts caused by
temperature change makes this noise.

 

Dust from the units

 

 

Dust may blow out from the unit after starting operation from
long resting time. Dust absorbed by the unit blows out.

 

The units give off odours

 

 

The unit absorbs the smell of rooms, furniture, cigarettes, etc.,
and then emits them.

The liquid crystal display of the remote controller shows "

"

Happens immediately after the main power supply switch is
turned on.
Shows that the remote controller is in normal condition.
Continues temporarily.

Do not use the air conditioner for other purposes.

In order to avoid any quality deterioration, do not use the
unit for cooling precision instruments, food, plants animals
or works of art.

Operation mode 

Your room

Other room(s)

Cooling

Dry

Fan only

Heating

Cooling

O

O

O

W

Dry

O

O

O

W

Fan only

O

O

O

W

Heating

W

W

W

O

 

 O: your unit can operate
 W: your unit in waiting mode

Summary of Contents for FHYBP100B7V1

Page 1: ...0B7V1 FBQ71B7V3B FBQ100B7V3B FBQ125B7V3B FCQ35B7V1 FCQ50B7V1 FCQ60B7V1 FCQ71B7V3B FCQ100B7V3B FCQ125B7V3B FDQ125B7V3B FDQ200B7V3B FDQ250B7V3B FHYBP71B8V1 FHYBP100B8V1 FHYBP125B8V1 FHYCP71B8V1 FHYCP100...

Page 2: ...10 30 10 30 10 27 RXS35 50 60 4MXS68 80 RZQ71 100 125 140 RP200 250 RR71 100 125 R35 45 60 RS50 60 RKS35 50 60 RXS35 50 60 3MKS50 4MKS58 75 90 3MXS52 3MXS52 4MXS68 80 80 80 80 80 80 80 5 43 5 43 10 46...

Page 3: ...ith remote controller 2 Unit without remote controller When used as simultaneous operation It is not good for your health to expose your body to the direct air flow for a long time In order to avoid e...

Page 4: ...er to Maintenance on page 4 When the display shows TIME TO CLEAN AIR FILTER have a qualified service person to clean the filters Refer to Maintenance on page 4 NOTE These units can be controlled by a...

Page 5: ...set temperature in heating mode the capacity supply from the outdoor unit has stopped and the indoor unit operates in fan only mode L tab In case of multi split the indoor unit alternately operates fa...

Page 6: ...oller If the air flow angle is not proper Refer to the manual of the remote controller If the doors or the windows are open Shut doors or windows to prevent wind from coming in If direct sunlight ente...

Page 7: ...air inlet grille Only for bottom suction 6 After turning on the power press FILTER SIGN RESET button The TIME TO CLEAN AIR FILTER display is turned off For FDYP and FDQ units See figure 5 1 Remove th...

Page 8: ...ower switch at least 6 hours before operation What to do when stopping the system for a long period Turn on FAN OPERATION for a half day and dry the unit Refer to the manual of the remote controller C...

Page 9: ...NOTES NOTES...

Page 10: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN10622 1E...

Reviews: