SPLIT SYSTEM

Air Conditioner

OPERATION MANUAL

MODELS

(Ceiling suspension type)

FH(Y)35BVE

FH(Y)71BVE

FH(Y)50BVE

FH(Y)100BVE

FH(Y)60BVE

FH(Y)125BVE

00_CV_3P170549-4C.fm  Page 1  Tuesday, November 6, 2007  9:30 AM

Summary of Contents for FHY35BVE x 2

Page 1: ...English Español SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling suspension type FH Y 35BVE FH Y 71BVE FH Y 50BVE FH Y 100BVE FH Y 60BVE FH Y 125BVE ...

Page 2: ...ny trouble occurs After reading the manual file it away for future reference Le agradecemos la compra de este acondicio nador de aire Daikin Lea cuidadosamente el manual de funciona miento antes de utilizar el acondicionador de aire Dicho manual le indicará cómo utilizar ade cuadamente la máquina y le ayudará en caso de avería Después de leer el manual con sérvelo para consultas futuras ...

Page 3: ... 1 1 3 4 2 TEST C hr hr TEST NOT AVAILABLE L H 2 10 11 3 1 4 5 6 7 8 14 15 16 17 18 19 20 21 22 12 9 13 b d e k R Y 71 j a k i h f f c e e d d R Y 100 125 R60 RY50 60 R35 50 RY35 g C hr H ...

Page 4: ...BEFORE OPERA TION Indoor unit Unit with remote controller Unit without remote controller When used as simultaneous operation system Outdoor unit PRECAUTIONS FOR GROUP CONTROL SYSTEM OR TWO REMOTE CONTROLLER CONTROL SYSTEM This system provides two other control systems beside individual control one remote controller con trols one indoor unit system Confirm the following if your unit is of the follo...

Page 5: ...could be the cause Consult your dealer for assistance The refrigerant within the air conditioner is safe and normally does not leak However in the event of a leakage contact with a naked burner heater or cooker may result in generation of noxious gas Do not longer use the air conditioner until a qual ified service person confirms that the leakage has been repaired Consult your local dealer regardi...

Page 6: ...out door units Under certain conditions condensation on the main unit or refrigerant pipes air filter dirt or drain blockage may cause dripping resulting in fouling or failure of the object concerned Do not place appliances that produce naked flames in places exposed to the air flow from the unit as this may impair combustion of the burner Do not place heaters directly below the unit as resulting ...

Page 7: ...to 25 WB R71 100 125 140KUV1 Y1 LUV1 Y1 VAL TAL YAL 21 to 46 DB 21 to 35 DB 14 to 25 WB R71 100 125KUVAL TAL 21 to 46 DB 21 to 35 DB 14 to 25 WB HEAT PUMP TYPE DB Dry bulb temperature WB Wet bulb temperature The setting temperature range of the remote con troller is 16 C to 32 C Regarding places for installation Is the air conditioner installed at a well ventilated place where there are no obstacl...

Page 8: ...buttons on the BRC1B type are slightly different they may be oper ated in the same manner 5 NAME AND FUNCTION OF EACH SWITCH AND DISPLAY ON THE REMOTE CONTROLLER 1 ON OFF BUTTON Press the button and the system will start Press the button again and the system will stop 2 OPERATION LAMP RED The lamp lights up during operation 3 DISPLAY UNDER CENTRAL IZED CONTROL When this display shows the system is...

Page 9: ...on mode COOL HEAT changeover is automatically conducted FAN OPERATION DRY OPERATION The function of this program is to decrease the humidity in your room with the minimum tem perature decrease Micro computer automatically determines TEMPERATURE and FAN SPEED This system does not go into operation if the room temperature is below 16 C Refer to figure 3 on page 1 For cooling only type COOLING FAN an...

Page 10: ...DIRECTION ADJUST button to select the air direction as shown below The AIR FLOW FLAP display swings as shown below and the air flow direction continuously varies Automatic swing set ting Press AIR FLOW DIRECTION ADJUST button to select the air direction of your choice The AIR FLOW FLAP display stops swinging and the air flow direction is fixed Fixed air flow direction setting MOVEMENT OF THE AIR F...

Page 11: ... the system operates Adjust the room temperature properly for a com fortable environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room dur ing cooling operation by using curtains or blinds Ventilate the room regularly Using the unit for long periods of time requires attentive ventilation of the room Keep doors and windows closed If the doors and windows remain ope...

Page 12: ... If the dirt becomes impossible to clean change the air filter Air filter for exchange is optional 1 Open the suction grille Slide both knobs simultaneously as shown and then pull them downward Do the same procedure for closing Refer to Fig 2 2 Remove the air filters Push the 2 tabs up and slowly lower the grille Refer to Fig 3 3 Clean the air filter Use vacuum cleaner A or wash the air filter wit...

Page 13: ...t blocked Remove any obstacle Check if the earth is connected Might there be a broken wire somewhere Contact your dealer if there are any problems Clean the air filter and outside panels After cleaning the air filter make sure to attach it Turn on the main power supply switch The display on the remote controller will be shown when the power is turned on To protect the unit turn on the main power s...

Page 14: ...uslow Shah soundisheardwhenthe system is in COOLING OPERATION or at a stop The noise is heard when the drain pump is in operation A Pishi pishi squeaking sound is heard when the system is in operation or after the stop of operation Expansion and contraction of plastic parts caused by temperature change makes this noise IV DUST FROM THE UNITS Dust may blow out from the unit after starting operation...

Page 15: ...Check if the air filter is clogged Ask a qualified service person to clean the air filters Refer to MAINTENANCE 3 The system operates but it does not suffi ciently cool or heat If the air inlet or outlet of the indoor or the out door unit is blocked with obstacles Remove the obstacle and make it well venti lated If the air filter is clogged Ask a qualified service person to clean the air filters R...

Page 16: ... 7 1 6110 27 62 R22 1 75 FHY71BVE RY71FUVAL 220 60 4 3 20 3 6 7 5800 3 8 18 0 8 5 7300 27 91 R22 2 3 FHY100BVE RY100FUVAL 220 60 5 9 27 6 9 0 7700 5 0 23 5 11 8 10100 32 120 R22 2 6 FHY125BVE RY125FUTAL 220 60 6 6 18 1 12 5 10800 5 42 14 9 15 0 12900 35 115 R22 3 1 THAILAND THAILAND DAIKIN INDUSTRIES THAILAND LTD DAIKIN INDUSTRIES THAILAND LTD THAILAND THAILAND DAIKIN INDUSTRIES THAILAND LTD DAIKI...

Page 17: ...3P170549 4C EM00A035B 0712 HT ...