5

Multi Connection

Note for Multi System

A multi system has one outdoor unit connected to multiple indoor units.

Selecting the operation mode

When the priority room setting is active
but the set unit is not operating or when
the priority room setting is inactive

When more than one indoor unit is operating, priority is given to

the first unit that was turned on.

In this case, set the units that are turned on later to the same

operation mode as the first unit.
Otherwise, they will enter the standby state, and when using the wired 
remote controller the centralized control icon “CENTRAL CONTROL” 

will light up; this does not indicate malfunction.

NOTE

Notes on operation mode for a multi system

• COOL, DRY and FAN operation may be used at the same time.
• AUTO operation automatically selects COOL operation or HEAT operation based on the indoor temperature.

 

Therefore, AUTO operation is available when selecting the same operation mode as that of the room with the first unit to be turned on.

 CAUTION

•  Normally, the operation mode in the room where the unit is first started is given priority, but the following situations are exceptions to this rule.

 

If the operation mode of the first room is FAN operation, then using HEAT operation in any room after this will give priority to HEAT operation. 

In this situation, the indoor unit operating in FAN mode will switch to standby, and when using the wired remote controller the centralized 
control icon “

CENTRAL CONTROL” will light up.

With the priority room setting active

Refer to “

Priority room setting

” on the next page.

NIGHT QUIET mode (Available only for COOL operation)

NIGHT QUIET mode requires initial programing during installation. Please consult your retailer or dealer for assistance.
NIGHT QUIET mode reduces the operation noise of the outdoor unit during the night-time hours to prevent annoyance to neighbours.

•  NIGHT QUIET mode is activated when the temperature drops 10.8°F (6°C) or more below the highest temperature recorded that day. 

 

When the temperature difference between the current outdoor temperature and the maximum outdoor temperature becomes less than 

7.2°F (4°C), this function will be canceled.

•  NIGHT QUIET mode slightly reduces the cooling efficiency of the unit.

QUIET OUTDOOR UNIT operation (Function unavailable in the FFQ series)

For details on QUIET OUTDOOR UNIT operation, refer to the operation manual included with the remote controller.

When the priority room setting is active but the set unit is not operating or when the 

priority room setting is inactive

When using the QUIET OUTDOOR UNIT operation feature with a multi system, set all indoor units to QUIET OUTDOOR 

UNIT operation using their remote controllers.

When canceling QUIET OUTDOOR UNIT operation, simply cancel the mode on one of the operating indoor units using their remote controller.
However QUIET OUTDOOR UNIT operation will remain displayed on the remote controllers for the other rooms.

We recommend you cancel operation in all rooms using their remote controllers.

With the priority room setting active

Refer to “

Priority room setting

” on the next page.

Room A

Room B

Room C

Room D

Outdoor unit

01_EN_3P674698-1.indd   5

3/15/2022   4:35:52 PM

Summary of Contents for FFQ09W2VJU9

Page 1: ...rt Enjoy year round comfort Enjoy year round comfort Enjoy year round comfort DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL English Fran ais Espa ol MODELS FFQ09W2VJU9 FFQ12W2VJU9 FFQ15W2VJU9 FFQ18W2VJ...

Page 2: ...not install the unit in an area where flammable materials are present due to risk of explosion resulting in serious injury or death Any abnormalities in the operation of the air conditioner or heat pu...

Page 3: ...an other than those recommended by the manufacturer The appliance must be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an oper...

Page 4: ...s where oil may splatter or where there is steam in the air g Locations where equipment produces electromagnetic waves h Places with an acid or alkaline mist i Places where fallen leaves can accumulat...

Page 5: ...nit The appearance of the outdoor unit may differ between different models The appearance of the suction grille and remote controller may differ between different models Refrigerant pipes Ground termi...

Page 6: ...ty room setting active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programing during installation Please consul...

Page 7: ...on mode in room B C and D Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN The current operation mode is maintained HEAT The unit enters the standby mode Operat...

Page 8: ...ference Cleaning parts Notes on cleaning For cleaning do not use any of the following Water hotter than 104 F 40 C Volatile liquid such as benzene gasoline and thinner Polishing compounds or liquid in...

Page 9: ...ard to disconnect the hooks and remove the air filter Hook Knob 3 Clean the air filter with a vacuum cleaner or wash it with water If the dust does not come off easily Wash the air filter using a soft...

Page 10: ...Directly apply the type of detergent used for cleaning ventilation fans or ovens wait for about 10 minutes and then rinse with water 5 Reattach the air filter Page 8 6 Reattach the suction grille Refe...

Page 11: ...he operation refer to the operation manual for the remote controller 2 After operation stops turn off the circuit breaker for the room air conditioner 3 Clean the air filter and reattach it 4 To preve...

Page 12: ...ler where you bought the air conditioner The outdoor fan rotates while the air conditioner is not in operation After operation is stopped The outdoor fan continues rotating for another 1 minute for sy...

Page 13: ...75 F 15 24 C MXL models 5 2 75 F 15 2 24 C MXLH models 13 75 F 25 24 C RX models 5 75 F 15 24 C 2 13 F 25 C If a drain pan heater sold separately is installed Indoor temperature 50 86 F 10 30 C Call...

Page 14: ...3P674698 1 M21B351 2203 HT The two dimensional bar code is a manufacturing code 00_CV_3P674698 1 indd 2 3 30 2022 4 28 58 PM...

Reviews: