English

4

 Refer to figure 1 on page [1] 

To protect the unit, turn on the main power switch 
6 hours before operation.

Do not turn off the main power supply during 
operation season. Because the air conditioner is 
smoothly started.

Operate in the following order.

OPERATION MODE SELEC-
TOR

Press OPERATION MODE SELECTOR but-
ton several times and select the OPERATION 
MODE of your choice as follows.

 

COOLING OPERATION ........................ “

 

HEATING OPERATION ......................... “

 

AUTOMATIC OPERATION..................... “

In this operation mode, COOL/HEAT 
changeover is automatically conducted.
(not available to FDY15, 20 type)

 

FAN OPERATION .................................. “

14

INSPECTION/TEST OPERATION BUTTON

This button is used only by qualified service 
persons for maintenance purposes.

15

PROGRAMMING TIME BUTTON

Use this button for programming “START and/
or STOP” time.

16

TEMPERATURE SETTING BUTTON

Use this button for SETTING TEMPERATURE.

17

FILTER SIGN RESET BUTTON

Not applied on this model.

18

OPERATION MODE SELECTOR BUTTON

Press this button to select OPERATION MODE.

NOTE

For the sake of explanation, all indications are 
shown on the display in Figure 1 contrary to 
actual running situations.

6. OPERATION PROCEDURE

COOLING, HEATING,  AUTOMATIC, AND 
FAN OPERATION

1

 ON/OFF

Press ON/OFF button

OPERATION lamp lights up and the system starts 
OPERATION.

[EXPLANATION OF HEATING OPERATION]

DEFROST OPERATION

As the frost on the coil of an outdoor unit increase, 
heating effect decreases and the system goes 
into DEFROST OPERATION.

During DEFROST OPERATION the remote con-
troller display shows “

” and there are 

cases where the indoor unit fan stops.

After 6 to 8 minutes (maximum 10 minutes) of 
DEFROST OPERATION, the system returns to 
HEATING OPERATION.

Regarding outside air temperature and heat-
ing capacity

The heating capacity of the air conditioner 
declines as the outside air temperature falls. In 
such a case, use the air conditioner in combina-
tion with other heating systems.

A warm air circulating system is employed, and 
therefore it takes some time until the entire room 
is warmed up after the start of operation.

An indoor fan runs to discharge a gentle wind 
automatically until the temperature inside the air 
conditioner reaches a certain level. At this time, 
the remote controller displays “

”. Leave it 

as it stands and wait for a while.

When the warm air stays under the ceiling and 
your feet are cold, we recommend that you use a 
circulator (a fan to circulate the air inside the 
room). For details, consult your dealer.

For programming TEMPERATURE, follow the pro-
cedure shown below.

TEMPERATURE SETTING 

Press TEMPERATURE SETTING button and 
program the setting temperature.

Each time this button is pressed, setting 
temperature rises 1°C.

Each time this button is pressed, setting 
temperature lowers 1°C.

The setting is impossible for fan operation.

NOTE

The setting temperature range of the remote controller.
COOLING OPERATION ............ 18 to 35 °C
HEATING OPERATION ............. 15 to 30 °C

2

ADJUSTMENT

Summary of Contents for FDY06KAY1

Page 1: ...Conditioner OPERATION MANUAL MODELS Duct Connection type FDY06KAY1 FDY08KATAL FDY08KAYAL FDY08KAY1 FDY10KATAL FDY10KAYAL FDY10KAY1 FDY15KATAL FDY15KAYAL FDY15KAY1 FDY20KATAL FDY20KAYAL FDY20KAY1 Engli...

Page 2: ...ikin air condi tioner Carefully read this operation manual before using the air conditioner It will tell you how to use the unit properly and help you if any trouble occurs After reading the manual fi...

Page 3: ...1 1 3 2 TEST NOT AVAILABLE TEST hr hr A 2 10 4 5 6 7 3 9 8 11 12 13 14 15 16 17 18 1 RY140 e a d h C f g e b d h C hr hr...

Page 4: ...his air conditioner comes under the term appli ances not accessible to the general public The precautions described below are WARN ING and CAUTION These are very important precautions concerning safet...

Page 5: ...er cord from the outlet Otherwise an electric shock and injury may result Do not operate the air conditioner with a wet hand An electric shock may result Do not use any fuse with improper capacity The...

Page 6: ...executed to perform com plete drainage If proper drainage is not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe Thi...

Page 7: ...oor unit increase heating effect decreases and the system goes into DEFROST OPERATION During DEFROST OPERATION the remote con troller display shows and there are cases where the indoor unit fan stops...

Page 8: ...room temperature properly for a comfort able environment Avoid excessive heating or cooling Prevent direct sunlight from entering a room dur ing cooling operation by using curtains or blinds Keep doo...

Page 9: ...mp lights the system is in its normal operating condition It does not restart immediately because one of its safety devices actuates to prevent the system from being overloaded The system will turn on...

Page 10: ...ECTION UNIT No and the OPERATION lamp flash and the MAL FUNCTION CODE appears 10 TROUBLE SHOOTING Measure Notify your Daikin dealer and inform him her of the display II If the system does not properly...

Page 11: ...3PN02535 8L EM01A060 0108 HT...

Reviews: