background image

DAIKIN ROOM AIR CONDITIONER   

OPERATION MANUAL

MODELS 

FDXS25LVMA
FDXS35LVMA
FDXS50LVMA
FDXS60LVMA

00_CV_3P297309-1.indd   1

00_CV_3P297309-1.indd   1

10/21/2011   9:11:05 PM

10/21/2011   9:11:05 PM

Summary of Contents for FDXS25LVMA

Page 1: ...DAIKIN ROOM AIR CONDITIONER OPERATION MANUAL MODELS FDXS25LVMA FDXS35LVMA FDXS50LVMA FDXS60LVMA 00_CV_3P297309 1 indd 1 00_CV_3P297309 1 indd 1 10 21 2011 9 11 05 PM 10 21 2011 9 11 05 PM...

Page 2: ...ECONO This function enables efficient operation by limiting the maximum power consumption It is useful when using the air conditioner and other electrical devices simultaneously Page 16 01_EN_3P297309...

Page 3: ...Adjusting the Airflow Rate 13 POWERFUL Operation 14 OUTDOOR UNIT QUIET Operation 15 ECONO Operation 16 OFF TIMER Operation 17 ON TIMER Operation 18 Multi Connectio n Note for Multi System 19 Car e Ca...

Page 4: ...perating correctly i e not generating cool or warm air refrigerant leakage could be the cause Consult your dealer for assistance The refrigerant within the air conditioner is safe and normally does no...

Page 5: ...f the outdoor unit and do not let leaves and other debris accumulate around the unit Leaves are a hotbed for small animals which can enter the unit Once in the unit such animals can cause malfunctions...

Page 6: ...once to start operation Press once again to stop it The operation mode refers to the following table Mode Temperature setting Airflow rate AUTO 25 C AUTO This switch is useful when the remote control...

Page 7: ...Refrigerant piping and inter unit wiring Earth terminal It is inside of this cover Drain hose Air inlet back and side Air outlet Outdoor temperature sensor back Model name plate 01_EN_3P297309 1 indd...

Page 8: ...tely 4m ECONO button ECONO operation Page 16 POWERFUL button POWERFUL operation Page 14 Display LCD It displays the current settings In this illustration each section is shown with all its displays on...

Page 9: ...ezes Use a thin object to push CLOCK button Page 10 QUIET button OUTDOOR UNIT QUIET operation Page 15 ON TIMER button Page 18 OFF TIMER button Page 17 MODE selector button It selects the operation mod...

Page 10: ...ely 1 year If the remote controller display begins to fade and the degradation of reception performance occurs within a year however replace both batteries with new size AAA LR03 alkaline The attached...

Page 11: ...To set the clock Press 1 is displayed blinks Press 2 to set the clock to the present time Press 3 blinks 01_EN_3P297309 1 indd 10 01_EN_3P297309 1 indd 10 10 22 2011 11 03 37 AM 10 22 2011 11 03 37 A...

Page 12: ...er the start of HEAT operation it takes some time before the room gets warmer In HEAT operation frost may occur on the outdoor unit and lower the heating capacity In that case the system switches into...

Page 13: ...consumes a small amount of electricity even while it is not operating If you are not going to use the air conditioner for a long period for example in spring or autumn turn the breaker off Use the air...

Page 14: ...t to indoor unit quiet operation will start and the noise from the unit will become quieter In indoor unit quiet operation the airflow rate is set to a weak level In DRY operation the airflow rate set...

Page 15: ...h ECONO and OUTDOOR UNIT QUIET operation Priority is given to the function of whichever button is pressed last POWERFUL operation can only be set when the unit is running Pressing the operation stop b...

Page 16: ...IT QUIET operation will work only when this function is set on all operated indoor units However if using priority room setting refer to note for multi system Page 19 This function is available in COO...

Page 17: ...liances are used at same time Time Maximum during normal operation Maximum during ECONO operation Normal operation ECONO operation From start up until set temperature is reached Running current and po...

Page 18: ...LCD The TIMER lamp lights yellow Display To cancel OFF TIMER operation Press disappear from the LCD is displayed on the LCD The TIMER lamp goes off NOTE Notes on TIMER operation When TIMER is set the...

Page 19: ...ting time are displayed on the LCD The TIMER lamp lights yellow Display To cancel ON TIMER operation Press disappears from the LCD is displayed on the LCD The TIMER lamp goes off To combine ON TIMER a...

Page 20: ...th the priority room setting active Refer to Priority room setting on the next page NIGHT QUIET mode Available only for COOL operation NIGHT QUIET mode requires initial programming during installation...

Page 21: ...Status of room B C and D when the unit in room A is in COOL operation COOL or DRY or FAN Current operation mode maintained HEAT The unit enters standby mode Operation resumes when the room A unit stop...

Page 22: ...y rinse them in cool water Do not use detergent or hot water to avoid filter shrinking or deformation After cleaning dry them in the shade Replacing the air filter 3 Rear suction Hook the filter behin...

Page 23: ...the air inlets and the outlets of the indoor unit and the outdoor unit Check that the drain comes smoothly out of the drain hose during COOL or DRY operation If no drain water is seen water may be le...

Page 24: ...refrigerant in the air conditioner is flowing This is a pumping sound of the water in the air conditioner and heard when the water is pumped out from the air conditioner in cooling or drying operation...

Page 25: ...ION lamp flashes Are the air filters clean Is there anything to block the air inlet or the outlet of the indoor and the outdoor units Clean the air filters or take all obstacles away and turn the brea...

Page 26: ...gives out odour This happens when smells of the room furniture or cigarettes are absorbed into the unit and discharged with the airflow If this happens we recommend you to have the indoor unit washed...

Page 27: ...rmal sound is heard during operation The safety breaker a fuse or the earth leakage breaker cuts off the operation frequently A switch or a button often fails to work properly There is a burning smell...

Page 28: ...NSOR OUTDOOR UNIT EA COOLING HEATING SWITCHING ERROR E1 CIRCUIT BOARD FAULT E5 OL STARTED E6 FAULTY COMPRESSOR START UP E7 DC FAN MOTOR FAULT E8 OVERCURRENT INPUT F3 HIGH TEMPERATURE DISCHARGE PIPE CO...

Page 29: ...28 MEMO 01_EN_3P297309 1 indd 28 01_EN_3P297309 1 indd 28 10 22 2011 11 06 27 AM 10 22 2011 11 06 27 AM...

Page 30: ...29 MEMO 01_EN_3P297309 1 indd 29 01_EN_3P297309 1 indd 29 10 22 2011 11 06 27 AM 10 22 2011 11 06 27 AM...

Page 31: ...30 MEMO 01_EN_3P297309 1 indd 30 01_EN_3P297309 1 indd 30 10 22 2011 11 06 28 AM 10 22 2011 11 06 28 AM...

Page 32: ...3P297309 1 M11B122 1111 HT Two dimensional bar code is a code for manufacturing Quick Reference 00_CV_3P297309 1 indd 2 00_CV_3P297309 1 indd 2 10 21 2011 9 11 19 PM 10 21 2011 9 11 19 PM...

Reviews: