Explanation of heating operation

 

Master-slave unit system (mode batting)

 

 

System operation mode cool or heat is determined by the mode
the master unit is in. When the master unit is in cool mode,
respectively heat mode, the system can only operate in cooling,
respectively heating, regardless of the thermostat setting.

 

 

When the master unit is OFF, the system mode is determined by
the unit which is switched on first.

 

O

 

PTIMUM

 

 

 

OPERATION

 

Observe the following precautions to ensure the system operates
properly.

 

 

Adjust the air outlet properly and avoid direct air flow to room
inhabitants.

 

 

Adjust the room temperature properly for a comfortable
environment. Avoid excessive heating or cooling.

 

 

Prevent direct sunlight from entering a room during cooling
operation by using curtains or blinds.

 

 

Keep doors and windows closed. If the doors and windows
remain open, air will flow out of your room causing a decrease in
the cooling or heating effect.

 

 

Never place objects near the air inlet or the air outlet of the unit.
It may cause deterioration in the effect or stop in the operation.

 

 

Turn off the main power supply switch to the unit when the unit is
not used for longer periods of time. If the switch is on, it uses
electricity. Before restarting the unit, turn on the main power
supply switch 6 hours before operation for smooth running.
(Refer to 

"Maintenance" on page 3

)

 

 

When the display shows "

" (time to clean the air filter), ask

a qualified service person to clean the filters. (Refer to

"Maintenance" on page 3

)

 

F

 

OLLOWING

 

 

 

SYMPTOMS

 

 

 

ARE

 

 

 

NOT

 

 

 

AIR

 

 

 

CONDITIONER

 

 

 

TROUBLES

 

The system does not operate

 

 

The system does not restart immediately after the ON/OFF
button is pressed.
If the OPERATION lamp lights, the system is in its normal
operating condition.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded. 
The system will turn on again automatically after three minutes.

 

 

The system does not restart immediately when the
TEMPERATURE SETTING button is returned to the former
position after pushing.
It does not restart immediately because one of its safety devices
actuates to prevent the system from being overloaded. 
The system will turn on again automatically after three minutes.

 

 

The system does not start when the display shows "

"

(EXTERNAL CONTROL ICON) and it flashes for a few seconds
after pressing an operation button.
This is because the system is controlled or disabled by another
controller with a higher priority.
When the display flashes, it indicates that the system cannot be
controlled by this indoor unit.

 

 

The system does not start when the display shows "

".

This indicates that the change-over of the installation is under
centralized control asigned to another unit or to an optional cool/
heat selector connected to the outdoor unit (= master remote
controller).
The indoor unit has to be restarted with the controller.

 

 

The system does not start immediately after the power supply is
turned on.
Wait one minute until the micro computer is prepared for
operation.

 

White mist comes out of a unit

 

 

When humidity is high during cooling operation (in oily or dusty
places)
If the inside of an indoor unit is extremely contaminated, the
temperature distribution inside a room becomes uneven. It is
necessary to clean the inside of the indoor unit. Ask your Daikin
dealer for details on cleaning the unit. This operation requires a
qualified service person.

 

 

When the system is changed over to HEATING OPERATION
after DEFROST OPERATION.
Moisture generated by DEFROST becomes steam and exits.

 

Noise of air conditioners

 

 

A continuous low "hissing" sound is heard when the system is in
COOLING or DEFROST OPERATION.
This is the sound of refrigerant gas flowing through both indoor
and outdoor units.

 

 

A "hissing" sound which is heard at the start or immediately after
the stop of operation or which is heard at the start or
immediately after the stop of DEFROST OPERATION.
This is the noise of refrigerant caused by flow stop and flow
change.

 

 

A continuous low "swishing" sound is heard when the system is
in COOLING OPERATION or at a stop.
The noise is heard when the drain pump is in operation.

 

 

A "squeaking" sound is heard when the system is in operation or
after the stop of operation.
Expansion and contraction of plastic parts caused by
temperature change makes this noise.

 

Dust from the units

 

 

Dust may blow out from the unit after starting operation from
long resting time.
Dust absorbed by the unit blows out.

 

The units give off odors

 

 

The unit absorbs the smell of rooms, furniture, cigarettes, etc.,
and then emits them.

 

The liquid crystal of the remote controller shows "

 

 

Happens immediately after the main power supply switch is
turned on.
Shows that the remote controller is in normal condition.
Continues temporary.

 

 

If a function that is not available is selected, the
message NOT AVAILABLE will appear.

 

 

To  protect the unit, turn on the main power switch 6
hours before operation.

 

 

If the main power supply is turned off during
operation, operation will restart automatically after the
power turns back on again.

 

NOTE

 

The master-slave setting is decided upon and set
during installation.

Summary of Contents for FDBQ25B7V1

Page 1: ...OPERATION MANUAL FDBQ25B7V1 Split series room air conditioners Multi system room air conditioners ...

Page 2: ...1 5 5 4 4 3 7 6 9 8 1 2 2a 2b 3a 3b NOTES Pair Singolo Paar  ÁÔ Paire Par Pair Сплит Par Multi Multi Multi ÔÏÏ Ïfi Multi Multi Multi Много Multi 1 2a 2b 3a 3b ...

Page 3: ...nlet air 5 Discharged air 6 Refrigerant piping connection electric wire 7 Drain pipe 8 Ground wire 9 Suction air filter optional Pair Multi system combination Never let the indoor unit and the remote controller get wet It may cause an electric shock or a fire Never use flammable spray such as hair spray lacquer or paint near the unit It may cause a fire Never replace a fuse with that of a wrong am...

Page 4: ...ystem is controlled or disabled by another controller with a higher priority When the display flashes it indicates that the system cannot be controlled by this indoor unit The system does not start when the display shows This indicates that the change over of the installation is under centralized control asigned to another unit or to an optional cool heat selector connected to the outdoor unit mas...

Page 5: ...oling Use curtains or blinds When there are too many inhabitants in the room Cooling effect decreases if heat gain of the room is too large If the heat source of the room is excessive when cooling Cooling effect decreases if heat gain of the room is too large MAINTENANCE How to clean the air filter Clean the air filter when the display shows TIME TO CLEAN AIR FILTER Increase the frequency of clean...

Page 6: ...l and national legislation Your air conditioning product is marked with this symbol This means that electrical and electronic products shall not be mixed with unsorted household waste Do not try to dismantle the system yourself the dismantling of the air conditioning system treatment of the refrigerant of oil and of other parts must be done by a qualified installer in accordance with relevant loca...

Page 7: ...NOTES NOTES ...

Page 8: ...Zandvoordestraat 300 B 8400 Oostende Belgium 4PWEN15396 1B ...

Reviews: