1. WHAT TO DO BEFORE OPERATION ............ 1
2. SAFETY CONSIDERATIONS ......................... 2
3. OPERATION RANGE...................................... 3
4. INSTALLATION SITE ...................................... 4
5. OPERATION PROCEDURE ........................... 4
6. OPTIMUM OPERATION ................................. 5
7. MAINTENANCE

(FOR SERVICE PERSONNEL) ...................... 5

8. NOT MALFUNCTION OF THE AIR

CONDITIONER ............................................... 7

9. TROUBLE SHOOTING ................................... 8

Important information regarding the refrig-
erant used

This product contains fluorinated greenhouse gases 
covered by the Kyoto Protocol.
Refrigerant type : R410A

GWP

(1) 

value : 1975

(1)

GWP = global warming potential

Periodical inspections for refrigerant leaks may be 
required depending on European or local legislation. 
Please contact your local dealer for more information.

This operation manual is for the following system 
with standard control. Before initiating operation, 
contact your Daikin dealer for the operation that cor-
responds to your system.

NOTE

If the unit you purchased is controlled by a wire-
less remote controller, also refer to the wireless 
remote controller’s operation manual.

If your installation has a customized control system, 
ask your Daikin dealer for the operation that corre-
sponds to your system.

Heat pump type
This system provides cooling, heating, automatic, 
program dry, and fan operation modes.

1. WHAT TO DO BEFORE 

OPERATION

Indoor unit

Outdoor unit

Unit with
remote
controller

Unit without romote
controller
(When used as
simultaneous
operation system)

PRECAUTIONS FOR GROUP CONTROL 
SYSTEM OR TWO REMOTE CONTROLLERS 
CONTROL SYSTEM

This system provides two other control systems 
beside individual control (one remote controller con-
trols one indoor unit) system. Confirm the following if 
your unit is of the following control system type.

Group control system

One remote controller controls up to 16 indoor units.
All indoor units are equally set.

Two remote controllers control system

Two remote controllers control one indoor unit (In case 
of group control system, one group of indoor units)
The unit is individually operated.

NOTE

Contact your Daikin dealer in case of changing 
the combination or setting of group control and 
two remote controllers control systems.

Names and functions of parts

a

Indoor unit

b

Outdoor unit 

c

Remote controller

d

Inlet air

e

Discharge air

f

Air outlet

g

Air flow flap (at air outlet)

h

Refrigerant piping, connection electric wire

i

Drain pipe

j

Air inlet
The built-in air filter removes dust and dirt.

k

Drain pumping out device(built-in)
Condensate removed from the room during 
cooling.

l

Ground wire
Wire to ground from the outdoor unit to pre-
vent electrical shocks.

a

b

c

d

e

e

f

g

h

i

k

e

f

l

d

j

RZQ100·125·140

RZQ71

Summary of Contents for FCQ71DAV3B

Page 1: ...s Espa ol Italiano Nederlands Portugues SPLIT SYSTEM Air Conditioner OPERATION MANUAL MODELS Ceiling mounted Multi flow Cassette type FCQ71DV3B FCQ71DAV3B FCQ100DV3B FCQ100DAV3B FCQ125DV3B FCQ125DAV3B...

Page 2: ...dicio nador de aire Daikin Lea cuidadosamente el manual de funcionamiento antes de utilizar el acondicionador de aire Dicho manual le indi car c mo utilizar adecuadamente la m quina y le ayudar en cas...

Page 3: ...gerante aceite y otros componentes debe ser efectuado por un instalador competente de acuerdo con las normas locales y nacionales aplicables Los acondicionadores de aire deben ser tratados en instalac...

Page 4: ...operation modes 1 WHAT TO DO BEFORE OPERATION Indoor unit Outdoor unit Unit with remote controller Unit without romote controller When used as simultaneous operation system PRECAUTIONS FOR GROUP CONTR...

Page 5: ...oxygen deficiency accident may happen 2 SAFETY CONSIDERATIONS For installation of separately sold compo nent parts ask a specialist Be sure to use the separately sold component parts designated by ou...

Page 6: ...ly if power failure compensation is enabled which may result in injury Do not place objects in direct proximity of the outdoor unit and do not let leaves and other debris accumulate around the unit Le...

Page 7: ...not carried out from the out door drain pipes during air conditioning operation chances are that dust and dirt are clogged in the pipe This may result in a water leakage from the indoor unit Under suc...

Page 8: ...iling Set the air flow direction parallel during cooling or dry operation and set it downwards during heat ing operation Do not let the air blow directly to a person ONLY A QUALIFIED SERVICE PERSON IS...

Page 9: ...off Do not use water or air of 50 C or higher for clean ing air filters and outside panels HOW TO CLEAN THE SUCTION GRILLE 1 Open the suction grille Push it downward slowly while pressing the but tons...

Page 10: ...lled by the remote con troller 8 NOT MALFUNCTION OF THE AIR CONDITIONER The system does not start immediately after the power supply is turned on Wait one minute until the micro computer is pre pared...

Page 11: ...does not operate at all Check if there is a power failure Wait until power is restored If power failure occurs during operation the system automati cally restarts immediately after the power sup ply...