background image

11

 

The above operation is performed not only 
at the time of installation, but every time the 

p

ower circuit breaker is turned off/on.

For comfortable use, do not turn off the 

p

ower circuit breaker during seasonal use of 

the HEATING OPERATION.

• 

The

 

outdoor

 

unit

 

stops.

This is because the indoor temperature has 
reached the set temperature.
The indoor unit is in the FAN OPERATION.

COOLING OPERATION 
(AUTOMATIC COOLING OPERATION):
Lower the set temperature.
HEATING OPERATION 
(AUTOMATIC HEATING OPERATION):
Raise the set temperature.

The operation starts after a while when the 
air conditioner is in normal condition.

• 

The

 

remote

 

controller

 

displays

 

 

 

This is because the air conditioner 
automatically switches to the DEFROST 
OPERATION to prevent a decrease in 
heating capacity when frost on the outdoor 
unit increases.
After maximum 10 minutes, the air 
conditioner returns to its original operation.

THE

 

OPERATION

 

SOMETIMES

 

STOPS

• 

The

 

remote

 

controller

 

displays

 

“U4”

 and 

“U5”,

 

and

 

the

 

operation

 

stops.

 

However

it

 

will

 

restart

 

in

 

a

 

few

 

minutes.

This is because communication between the 
indoor and outdoor units or indoor units and 
remote controllers is shut off and stops the 
operation due to noise caused by devices 
other than the air conditioner.
When the electrical noise decreases, the air 
conditioner automatically restarts.

 

THE

 

FAN

 

SPEED

 

IS

 

DIFFERENT

 

FROM

 

TH

SETTING

• 

Pressing

 

the

 

fan

 

speed

 

control

 

butt

on 

does

 

not

 

change

 

the

 

fan

 

speed.

During the COOLING OPERATION, the low 
fan speed or a gentle wind is used to prevent 
the discharge of melt water.
During the DEFROST OPERATION 
(HEATING OPERATION), the wind from the 
air conditioner stops to prevent air discharge 
directly toward your body.
After a while, the fan speed can be changed.
(The fan speed cannot be set for the 
PROGRAM DRY OPERATION.)
When the room temperature reaches the 
set temperature during the HEATING 
OPERATION, the outdoor unit stops and the 
indoor unit goes into gentle wind.

It takes some time until the fan speed 
changes. Raise the set temperature. After a 
while, the fan speed changes.

 

WHITE

 

MIST

 

COMES

 

OUT

 

OF

 

THE

 

AI

CONDITIONER

• 

When

 

humidity

 

is

 

high

 

during

 

the

 

COOL-

ING

 

OPERATION

 

(In

 

oily

 

or

 

dusty

 

places)

If the inside of an indoor unit is extremely 
contaminated, the temperature distribution 
inside a room becomes uneven. It is neces-
sary to clean the inside of the indoor unit.
Ask your local dealer for details on cleaning 
the indoor unit.
This cleaning requires a qualified service 
person.
Check the usage environment.

• 

When

 

the

 

air

 

conditioner

 

is

 

changed

 

ove

to

 

the

 

HEATING

 

OPERATION

 

after

 

th

DEFROST

 

OPERATION

 

and

 

in

 

the

 

DE-

FROST

 

OPERATION.

Moisture generated by defrost becomes 
steam and will float around.
When the remote controller display shows 
“ 

 ”, DEFROST OPERATION is being 

used.

NOISE

 

OF

 

AIR

 

CONDITIONERS

• 

which

 

is

 

heard

 

when

 

the

 

air

 

conditione

is

 

in

 

the

 

COOLING

 

or

 

DEFROST

 

OPERA-

TION

 

or

 

a

 

trickling

 

sound

 

which

 

is

 

hear

when

 

the

 

air

 

conditioner

 

is

 

in

 

the

 

DE-

FROST

 

OPERATION.

This is the sound of refrigerant gas flowing 
through both indoor and outdoor units.

• 

A

 

“Shuh”

 

sound

 

which

 

is

 

heard

 

at

 

th

start

 

or

 

immediately

 

after

 

the

 

stop

 

o

operation

 

or

 

which

 

is

 

heard

 

at

 

the

 

star

or

 

immediately

 

after

 

the

 

stop

 

of

 

the

 

DE-

FROST

 

OPERATION.

This is the noise of refrigerant caused by flow 
stop and flow change.
During the HEATING OPERATION, the 
air conditioner switches to the DEFROST 
OPERATION automatically.
The remote controller shows “ 

 

”.

After maximum 10 minutes, the

 

air 

conditioner returns to its original

 

operation.

• 

A

 

“Pishi-pishi”

 

squeaking

 

sound

 

is

 

hear

when

 

the

 

air

 

conditioner

 

is

 

in

 

operati

on 

or

 

after

 

the

 

stop

 

of

 

operation.

Expansion and contraction of resin parts 
caused by temperature change makes this 
noise.

and airflow stops.

A low continuous flow “Shuh” sound

2. 

3. 

4. 

5. 

Summary of Contents for FBA50BVMA

Page 1: ...MODELS Ceiling mounted Duct type FBA50BVMA FBA60BVMA FBA50BAVMA FBA60BAVMA FBA71BVMA FBA100BVMA FBA125BVMA FBA140BVMA OPERATION MANUAL SPLIT SYSTEM Air Conditioner FBA85BVMA...

Page 2: ...can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruct...

Page 3: ...a defect results from your own workmanship it may result in water leakage electric shocks or a fire 2 WARNING Do not use means to accelerate the defrosting process or to clean other than those recomme...

Page 4: ...y ensure that the room is adequately ventilated if equipment such as a burner is used together with the air conditioner Do not leave the remote controller wherever there is a risk of wetting If water...

Page 5: ...naked flames in places exposed to the airflow from the air conditioner as this may impair combustion of the burner Do not block air inlets nor outlets Impaired airflow may result in insufficient perf...

Page 6: ...e controllers control systems by yourself but be sure to ask your local dealer Read the operation manual attached to the remote controller you are using When using a wireless remote controller refer t...

Page 7: ...kaline steam or vapor Is a snow protection measure taken For details consult your local dealer about snow protection hoods etc Regarding wiring To do wiring ask your local dealer Never do it by yourse...

Page 8: ...After maximum 10 minutes of the DEFROST OPERATION the air conditioner returns to the HEATING OPERATION During or after the DEFROST OPERATION white mist comes out from the air inlet or outlet of the ai...

Page 9: ...1 m or more away from the indoor unit and remote controller Images may become fuzzy and noise may be generated Turn off the power circuit breaker when it is not in use for a long period When the power...

Page 10: ...volume of the air conditioner will result and the performance of the air conditioner will be degraded if the air lter is clogged with dust or dirt After completing cleaning and installing an air filt...

Page 11: ...is supplied to the air conditioner the indoor fan stops for about 10 minutes during the outdoor unit operation to protect the devices The above operation is performed not only at the time of installa...

Page 12: ...RY OPERATION When the room temperature reaches the set temperature during the HEATING OPERATION the outdoor unit stops and the indoor unit goes into gentle wind It takes some time until the fan speed...

Page 13: ...urs during operation the air conditioner automatically restarts immediately after the power supply recovers 2 If the air conditioner stops after operating the air conditioner Check if the air inlet or...

Page 14: ...ures shown below and contact your local dealer The air conditioner must be repaired by a qualified service person WARNING When the air conditioner is malfunctioning giving off a burning odour etc turn...