![Daikin FAA71BUV1B Installer And User Reference Manual Download Page 58](http://html1.mh-extra.com/html/daikin/faa71buv1b/faa71buv1b_installer-and-user-reference-manual_4704595058.webp)
16
|
Unit installation
Installer and user reference guide
58
FAA71+100BUV1B
Split system air conditioner
4P654517-1 – 2021.03
16.3.4 To hook the unit on the mounting plate
1
"16.2.1 To remove the front panel"
2
Set the indoor unit on the mounting plate hooks. Use the " " marks as a
guide.
3
Place piece of packing material for support.
a
c d
b
e
a
Front grille
b
Refrigerant piping
c
Tab 2×
d
Mounting plate (accessory)
e
Piece of packing material
16.3.5 To pass the pipes through the wall hole
1
Connect the drain piping
59], the refrigerant
piping
62] and the electrical wiring
2
Shape the refrigerant pipes along the pipe path marking on the mounting
plate.
3
Fix the electrical wiring and the refrigerant pipes together using vinyl tape
(field supply).
c
e
f
b
d
a
A
A
c g
a
Drain hose
b
Wall hole
c
Refrigerant piping
d
Electrical wiring
e
Vinyl tape (field supply)
f
Power supply wiring
g
Transmission wiring and user interface wiring
NOTICE
▪
Do NOT bend refrigerant pipes.
▪
Do NOT push the refrigerant pipes onto the bottom frame or the front grille.