9 Relocation
Installation and operation manual
12
FAA71+100BUV1B
Split system air conditioner
3P654518-1A – 2021.03
Malfunction
Measure
The operation switch does NOT function
properly.
Turn OFF the power
supply.
If the user interface displays
.
Notify your installer and
report the error code. To
display an error code see
the reference guide of the
user interface.
If the system does NOT operate properly except for the above
mentioned cases and none of the above mentioned malfunctions is
evident, investigate the system in accordance with the following
procedures.
INFORMATION
Refer to the reference guide located on
www.daikineurope.com/support-and-manuals/product-
information/
for more troubleshooting tips.
If after checking all above items, it is impossible to fix the problem
yourself, contact your installer and state the symptoms, the complete
model name of the unit (with manufacturing number if possible) and
the installation date (possibly listed on the warranty card).
9
Relocation
Contact your dealer for removing and reinstalling the total unit.
Moving units requires technical expertise.
10
Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling
of the system, treatment of the refrigerant, oil and other
parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for
reuse, recycling and recovery.
For the installer
11
About the box
11.1
Indoor unit
WARNING: MILDLY FLAMMABLE MATERIAL
The R32 refrigerant (if applicable) in this unit is mildly
flammable. Refer to the outdoor unit specifications for the
type of refrigerant to be used.
▪ At delivery, the unit MUST be checked for damage. Any damage
MUST be reported immediately to the claims agent of the carrier.
▪ Bring the packed unit as close as possible to its final installation
position to prevent damage during transport.
▪ Unpack the indoor unit completely according to the instructions
mentioned on the unpacking instructions sheet.
11.1.1
To remove the accessories from the
indoor unit
1
Remove:
▪ the accessory bag located at the bottom of the package,
▪ the mounting plate attached to the back of the indoor unit.
1×
1×
1×
4×
1×
3×
1×
c
b
a
d
e
f
g
a
Installation and operation manual
b
General safety precautions
c
Fixing screws M4×25L for the mounting plate (9×),
securing screws M4×12L (2× for 71 class, 3× for 100
class)
d
Tie wraps (1 large, 3 small)
e
Insulation tape
f
Screws cover (for 100 class only)
g
Mounting plate
12
Unit installation
INFORMATION
If you are not sure how to open or close parts of the unit
(front panel, electrical wiring box, front grille…) refer to the
installer reference guide of the unit for opening and closing
procedures.
WARNING
Installation shall be done by an installer, the choice of
materials and installation shall comply with the applicable
legislation. In Europe, EN378 is the applicable standard.
12.1
Preparing the installation site
Avoid installation in an environment with a lot of organic solvents
such as ink and siloxane.
WARNING
The appliance using R32 refrigerant shall be stored so as
to prevent mechanical damage and in a well-ventilated
room without continuously operating ignition sources (e.g.
open flames, an operating gas appliance, or an operating
electric heater). The room size shall be as specified in the
General safety precaution.
12.1.1
Installation site requirements of the
indoor unit
INFORMATION
The sound pressure level is less than 70 dBA.
CAUTION
Appliance not accessible to the general public, install it in a
secured area, protected from easy access.
This unit, both indoor and outdoor, is suitable for
installation
in
a
commercial
and
light
industrial
environment.