3 Operation

Operation manual

7

EWAQ+008BAVP
Packaged air-cooled water chillers and packaged air to water heat
pumps
4P478611-1 – 2017.02

[7]

[6.7]

[7.1]

[7.4]

[7.3]

Running hours

January
February
Total

User settings

Display

Temperature lock
Set schedules
Preset values
Allowed operation mode
Unit of measurement

Display

Contrast

Backlit LCD time
User profile
Available home pages

Set schedules

Room temp.
LWT main
Quiet mode

Preset values

Room temperature
LWT main
Quiet level

Set weather dependent

[7.7]

Set weather dependent

Main

[7.7.1] Main

Set weather-dependent heating

Set weather-dependent cooling

[6.8]

Version

User interface
Indoor unit
Outdoor unit

[7.6]

Unit of measurement

Decimal point

Temperature
Produced energy
Flow

INFORMATION

Depending  on  the  selected  installer  settings,  settings  will
be visible/invisible.

INFORMATION

January and February in Running hours are just examples
representing previous and current month respectively.

3.7

Installer settings: Tables to be
filled in by installer

3.7.1

Quick wizard

Setting

Default

Fill in…

Space heating/cooling settings [A.2.1]

Unit control method

2 (RT)

User interface location

1 (Room)

Pump operation mode

2 (Request)

Glycol present

0 (No)

Outdoor unit [A.2.2]

External sensor (outdoor)

0 (No)

Control box [A.2.2.E]

Setting

Default

Fill in…

Backup heater steps

0

BUH type

1 (1P,(1/1+2))

Preferential kWh rate

0 (No)

Contact type main

1 (Thermo)

Option box [A.2.2.F]

Ext. backup heat src

0 (No)

Alarm output

0 (NO)

External kWh meter 1

0 (No)

External kWh meter 2

0 (No)

External sensor (indoor)

0 (No)

PCC by digital inputs

0 (No)

Capacities [A.2.3]

BUH: step 1

Depends on
model

BUH: step 2

Depends on
model

3.7.2

Space heating/cooling control

Setting

Default

Fill in…

Leaving water temperature: Main zone [A.3.1.1]

LWT setpoint mode

1 (WD)

Leaving water temperature: Delta T source [A.3.1.3]

Summary of Contents for EWAQ006BAVP

Page 1: ...er chillers and packaged air to water heat pumps English Operation manual Packaged air cooled water chillers and packaged air to water heat pumps EWAQ006BAVP EWAQ008BAVP EWYQ006BAVP EWYQ008BAVP EKCB07...

Page 2: ...If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of General sa...

Page 3: ...l and desired values or between displaying actual and offset values if applicable on the home pages Goes to the next step when you are programming a schedule in the menu structure INFORMATION If you p...

Page 4: ...ure Room Scheduled Mon Tue To read out the actual and desired room temperature 1 Go to the room temperature home page Room Result You can read out the actual temperature 20 0 C Actual temperature 2 Pr...

Page 5: ...ave the schedule and give it a name See below for more details To program the schedule for Monday 1 Use and to select Monday 2 Press to enter the schedule for Monday 3 Program the schedule for Monday...

Page 6: ...r information Energy metering Error handling User permission level Actuators Operation modes Running hours Version Energy metering Consumed elec Produced energy Error information Error history Contact...

Page 7: ...e visible invisible INFORMATION January and February in Running hours are just examples representing previous and current month respectively 3 7 Installer settings Tables to be filled in by installer...

Page 8: ...efrigerant type R410A Global warming potential GWP value 2087 5 NOTICE In Europe the greenhouse gas emissions of the total refrigerant charge in the system expressed as tonnes CO2 equivalent is used t...

Page 9: ...INFORMATION When the backup heater takes over the heat load electricity consumption will be considerably higher 7 Disposal Do not try to dismantle the system yourself the dismantling of the system tre...

Page 10: ......

Page 11: ......

Page 12: ...4P478611 1 2017 02 Copyright 2017 Daikin...

Reviews: