background image

2 Quick guide

Operation manual

4

ET9W

Daikin Altherma 3 H MT F

4P634884-1 – 2021.03

2

Adjust the desired leaving water temperature.

+

35

°C

2

a

b

Main zone

+

45

°C

3

a

b

Additional zone

a

 Actual leaving water temperature

b

 Desired leaving water temperature

To change the weather-dependent curve for the space heating/
cooling zones

1

Go to the applicable zone:

Zone

Go to …

Main zone – Heating

[2.5] 

Main zone

 > 

Heating WD

curve

Main zone – Cooling

[2.6] 

Main zone

 > 

Cooling WD

curve

Additional zone – Heating

[3.5] 

Additional zone

 >

Heating WD curve

Additional zone – Cooling

[3.6] 

Additional zone

 >

Cooling WD curve

2

Change the weather-dependent curve.

There are 2 types of WD curves: 

slope-offset curve

 (default),

and 

2-points  curve

.  If  needed,  you  can  change  the  type  in

[2.E] 

Main  zone

  > 

WD  curve  type

.  The  way  to  adjust  the

curve depends on the type.

Slope-offset curve

Slope. 

When slope is changed,

the new preferred temperature at
X1 is unequally higher than the
preferred temperature at X2.

X1

X2

c

d

Y1

Y2

Y3

Y4

a

b

Offset

. When offset is changed,

the new preferred temperature at
X1 is equally higher as the
preferred temperature at X2.

Y1

Y2

Y3

Y4

X1

X2

a

b

c

d

X1, X2

Outdoor ambient temperature

Y1~Y4

Desired leaving water temperature

a

WD curve before changes

b

WD curve after changes

c

Slope

d

Offset

Possible actions on this screen

Select slope or offset.

Increase or decrease the slope/offset.

When slope is selected: set slope and go to offset.

When offset is selected: set offset.

Confirm changes and return to the submenu.

2-points curve

Y1

Y2

X1

X2

X1, X2

Outdoor ambient temperature

Y1, Y2

Desired leaving water temperature

Possible actions on this screen

Go through the temperatures.

Change the temperature.

Go to the next temperature.

Confirm changes and proceed.

More information

For more information, see also:

"4.4 Turning operation ON or OFF"

 [

4

 11]

"4.6 Space heating/cooling control"

 [

4

 12]

"4.8 Schedule screen: Example"

 [

4

 14]

"4.9 Weather-dependent curve"

 [

4

 15]

▪ User reference guide

Summary of Contents for ETVZ12S18EA6V ETVZ12S23EA6V

Page 1: ...Operation manual Daikin Altherma 3 H MT F English Operation manual Daikin Altherma 3 H MT F ETVZ12S18EA6V ETVZ12S23EA6V ETVZ12S18EA9W ETVZ12S23EA9W...

Page 2: ...her dependent curve 15 4 9 2 2 points curve 16 4 9 3 Slope offset curve 16 4 9 4 Using weather dependent curves 17 5 Energy saving tips 17 6 Maintenance and service 18 6 1 Overview Maintenance and ser...

Page 3: ...OFF space heating cooling operation C 2 Operation Space heating cooling room frost protection operation if enabled can still activate However for leaving water temperature control and external room th...

Page 4: ...the new preferred temperature at X1 is unequally higher than the preferred temperature at X2 X1 X2 c d Y1 Y2 Y3 Y4 a b Offset When offset is changed the new preferred temperature at X1 is equally high...

Page 5: ...nge the tank temperature setpoint In Reheat only mode you can use the tank temperature setpoint screen to read out and adjust the domestic hot water temperature 1 Go to 5 Tank Tank 5 2 Adjust the dome...

Page 6: ...duct information Addendum book for optional equipment Additional info about how to install optional equipment Format Paper in the box of the indoor unit Digital files on http www daikineurope com supp...

Page 7: ...urred See 7 1 To display the help text in case of a malfunction 418 for more information LCD screen The LCD screen has a sleeping function After 15 min of non interaction with the user interface the s...

Page 8: ...nt 1 5 Setpoint range Heating minimum Heating maximum Cooling minimum Cooling maximum 7 2 Time date Hours Minutes Year Month Day Daylight savings time Format 7 3 Holiday Activation From Till 7 4 Quiet...

Page 9: ...failure and system operates in Emergency mode or heat pump is forced off d Current date and time e Smart energy e1 Smart energy is available via solar panels or smart grid e2 Smart energy is currentl...

Page 10: ...in zone Shows the applicable symbol for your main zone emitter type Set the leaving water temperature for the main zone 3 Additional zone Restriction Only displayed if there are two leaving water temp...

Page 11: ...ng operation ON b Space heating cooling operation OFF Tank heating operation 55 21 35 45 c 55 21 35 45 d c Tank heating operation ON d Tank heating operation OFF 4 4 2 To turn ON or OFF Space heating...

Page 12: ...following options Heating Only heating mode Cooling Only cooling mode Automatic The operation mode changes automatically between heating and cooling based on the outdoor temperature Restricted per mo...

Page 13: ...ed to heat up the water to a preset value example Comfort 60 C During the morning you consume hot water and the DHW tank temperature decreases At 14 00 the DHW tank is programmed to heat up the water...

Page 14: ...ule to the other weekdays 5 Program the schedule for Saturday and copy it to Sunday 6 Give the schedule a name To go to the schedule 1 Go to 1 1 Room Schedule 2 Set scheduling to Yes 3 Go to 1 2 Room...

Page 15: ...and confirm the selected character The schedule name can contain up to 15 characters 5 Confirm the new name INFORMATION Not all schedules can be renamed 4 9 Weather dependent curve 4 9 1 What is a wea...

Page 16: ...and proceed 4 9 3 Slope offset curve Slope and offset Define the weather dependent curve by its slope and offset Change the slope to differently increase or decrease the temperature of the leaving wat...

Page 17: ...one Cooling WD curve Additional zone Heating 3 5 Additional zone Heating WD curve Additional zone Cooling 3 6 Additional zone Cooling WD curve Zone Go to Tank Restriction Only available to installers...

Page 18: ...gerant total refrigerant charge in kg 1000 Please contact your installer for more information WARNING FLAMMABLE MATERIAL The refrigerant inside this unit is mildly flammable WARNING Do NOT pierce or b...

Page 19: ...t water heating and space heating stops To manually recover it via the user interface go to the Malfunctioning main menu screen and confirm whether the backup heater can take over the heat load or not...

Page 20: ...of the system treatment of the refrigerant oil and other parts MUST comply with applicable legislation Units MUST be treated at a specialised treatment facility for reuse recycling and recovery 9 Glos...

Page 21: ......

Page 22: ......

Page 23: ......

Page 24: ...4P634884 1 2021 03 Copyright 2021 Daikin 4P634884 1 0000000V Verantwortung f r Energie und Umwelt...

Reviews: