4
|
Operation
User reference guide
42
ETVH/9W(G) + ETBH/9W
Daikin Altherma 3 H HT F+W
4P586456-1B – 2020.10
Schedule/Control
Description
[5.5]
Tank
>
Schedule
Schedule for the domestic hot
water tank temperature for
your normal domestic hot
water needs.
Predefined schedules:
1
Activation screen
: Not applicable. This schedule
is automatically activated if the DHW mode is
one of the following:
▪
Schedule only
▪
Sc reheat
Possible actions
:
▪
Comfort
: When to start heating the tank to
the user-defined preset value [5.2]
Comfort
setpoint
.
▪
Eco
: When to start heating the tank to the
user-defined
preset
value
[5.3]
Eco
setpoint
.
▪
Stop
: When to stop heating the tank, even if
the desired tank temperature is not reached
yet.
Note:
In
Sc reheat
mode, the
system also takes the user-defined preset value
[5.4]
Reheat setpoint
into account.
[7.4.2]
User settings
>
Quiet
>
Schedule
Schedule for when the unit has
to use which quiet mode level.
Predefined schedules:
1
Activation screen
: [7.4.1]
Activation
(only
available to installers).
Possible actions
: You can use the following
system-defined preset values:
▪
Quiet
▪
More quiet
▪
Most quiet
See
52].
[7.5.4]
User settings
>
Electricity price
>
Schedule
Schedule for when a certain
electricity tariff is valid.
Predefined schedules:
1
Activation screen
: Not applicable
Possible actions
: You can use the following
system-defined preset values:
▪
High
▪
Medium
▪
Low
See
"4.8.2 Setting the energy prices"
37].
Restriction:
Only available to
installers.
[9.4.2]
Installer settings
>
Booster heater
>
BSH
allowance schedule
Predefined schedules:
1
Activation screen
: Not applicable
Possible actions
: You can program 2 actions per
day.
▪
Off
: Booster heater operation NOT allowed.
▪
On
: Booster heater operation allowed.