Disposal
Installer reference guide
265
ERGA04~V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01
16 Disposal
NOTICE
Do NOT try to dismantle the system yourself: dismantling of the system, treatment of
the refrigerant, oil and other parts MUST comply with applicable legislation. Units
MUST be treated at a specialised treatment facility for reuse, recycling and recovery.
In this chapter
16.1 To drain the storage tank
DANGER: RISK OF BURNING/SCALDING
The water in the storage tank and all the connected piping can be very hot.
16.1.1 To drain the storage tank without a connected pressureless solar system
To prepare draining when no optional fill and drain kit is available
1
Open the screw plug of the spillover connection.
2
Unplug the spillover connector.
b
2
1
b
a
3
a
Spillover connector
b
Screw plug
3
Connect the loose end of the spillover drain hose to an appropriate drain.
To prepare draining when an optional fill and drain kit is available
1
Remove the connection cover from the screw plugs on the front.
2
Open the screw plug of the upper connection on the front.