9
|
Electrical installation
Installer reference guide
131
ERGA04~V3A+V37 + EHSH/X(B)04+08P30+50EF
Daikin Altherma 3 R ECH₂O
4P678716-1 – 2022.01
B
A
B
1~M
M2P
X 2M
1
7 8
A
3
Fix the cable with cable ties to the cable tie mountings. General information,
see
"9.3.1 To connect the electrical wiring to the indoor unit"
120].
9.3.8 To connect the alarm output
Wires: (2)×0.75 mm²
Maximum load: 0.3 A, 230 V AC
Maximum load: 1 A, 5 V DC
[9.D]
Alarm output
1
Open the following (see
"7.2.4 To open the indoor unit"
1
User interface panel
1
3
4
2
2
Switch box
3
Switch box cover
4
Top cover
2
Connect the alarm output cable to the appropriate terminals as shown in the
illustration below.