16
|
Technical data
Installer reference guide
263
EPRA08~W1 + ETVH/9W
Daikin Altherma 3 H MT F
4P634886-1 – 2021.03
16.3 Piping diagram: Indoor unit
3D120611B
B1PW
M3S
R8T
R2T
R1T
R5T
A
B
B
d
a2
a1
b2
b1
g
h
k
k
i
j
e
j
k
f
f
l
l
l
l
S1L
c2
c1
B1L
B
f
B
f
A
Indoor unit
B
Field installed
a1
Space heating/cooling – Water IN (screw connection, 1")
a2
Space heating/cooling – Water OUT (screw connection, 1")
b1
DHW – Cold water IN (screw connection, 3/4")
b2
DHW – Hot water OUT (screw connection, 3/4")
c1
Water IN from outdoor unit (screw connection, 1")
c2
Water OUT to outdoor unit (screw connection, 1")
d
Pump
e
Backup heater
f
Shut-off valve, male-female 1"
g
Expansion vessel
h
Magnetic filter/dirt separator
i
Safety valve
j
Air purge
k
Drain valve
l
Loose nut 1"
B1L
Flow sensor
B1PW
Space heating water pressure sensor
M3S
3-way valve (space heating/domestic hot water)
R1T
Thermistor (water IN)
R2T
Thermistor (backup heater – water OUT)
R5T, R8T
Thermistor (tank)
S1L
Flow switch
Screw connection
Flare connection
Quick coupling
Brazed connection