background image

Table of Contents

Installation and operation manual

2

EKRUCBS

Daikin Altherma simplified user interface

4P382251­1 – 2014.06

Table of Contents

For the user

2

1 Buttons

2

2 Status icons

2

For the installer

3

3 Overview: Installation and configuration

3

4 To connect the simplified user interface

3

5 To update the software with Updater

3

6 To update the software manually

4

For the user

1

Buttons

b

e

c

a

d

a

 SPACE HEATING/COOLING CONTROL

Go to the room temperature home page, where you can:
▪ Read out the actual room temperature.
▪ Press 

 or 

 to adjust the desired room temperature.

▪ Press 

 to turn ON or OFF the room temperature control.

b

 DOMESTIC HOT WATER CONTROL

Go to the domestic hot water home page, where you can:
▪ Read  out  the  actual  domestic  hot  water  tank  temperature

(only if the system contains a domestic hot water tank).

▪ Read  out  the  desired  instant  domestic  hot  water

temperature  (only  in  case  of  instant  domestic  hot  water
production by a boiler).

▪ Press 

  to  turn  ON  or  OFF  the  domestic  hot  water

control.

c

 DHW TANK BOOSTER MODE

Activate  the  DHW  tank  booster  mode  (only  if  the  system
contains  a  domestic  hot  water  tank,  and  provided  that  the
domestic hot water control is turned ON).

d

 ON/OFF

Turn  ON  or  OFF  the  space  heating/cooling  or  domestic  hot
water control (on the respective home pages).

e

 

 NAVIGATION BUTTONS

Adjust  the  desired  room  temperature  (on  the  room
temperature home page).

2

Status icons

Icon

Description

Space operation mode = Heating.

Space operation mode = Cooling.

Domestic hot water operation.

The DHW tank booster mode is active.

Unit is operating.

Actual temperature.

Desired temperature.

A malfunction occurred.

Emergency operation is active.

If 

  or 

  is  displayed,  check  the  main  user  interface  for  more

information or, if necessary, contact your installer.

Summary of Contents for EKRUCBS

Page 1: ...Installation and operation manual Daikin Altherma simplified user interface English Installation and operation manual Daikin Altherma simplified user interface EKRUCBS ...

Page 2: ...e system contains a domestic hot water tank Read out the desired instant domestic hot water temperature only in case of instant domestic hot water production by a boiler Press to turn ON or OFF the domestic hot water control c DHW TANK BOOSTER MODE Activate the DHW tank booster mode only if the system contains a domestic hot water tank and provided that the domestic hot water control is turned ON ...

Page 3: ...tware INFORMATION To update the software it is recommended to use Updater Updating the software manually can take up to 2 5 hours 4 To connect the simplified user interface 1 Connect the cable of the simplified user interface to the indoor unit X2M X5M A2P A2P 2 1 a b a Main user interface b Simplified user interface 2 Fix the cable with cable ties to the cable tie mountings 5 To update the softwa...

Page 4: ... your action Start copy Are you sure you want to start the copy operation Cancel OK Confirm Adjust Result A progress bar appears 4 Wait for the progress bar to finish and start flashing Result Both interfaces have identical software 5 Power OFF the indoor unit INFORMATION Copying the software from one user interface to the other transforms the receiver into the sender Depending on which interface ...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ...4P382251 1 2014 06 Copyright 2014 Daikin ...

Reviews: