3.2

Brief description

The Daikin high-performance-hot water storage tank is a combi-
nation of a heat storage tank and instantaneous water heater.

The pressureless storage water serves as heat storage medium. 
Useful heat is supplied and removed via the spiral corrosion-re-
sistant heat exchanger, which is made from a corrugated 
stainless steel pipe (1.4404), and is completely immersed in the 
storage tank water. In the heat exchanger for domestic hot water 
generation, domestic hot water is stored at the temperature level 
of the preparation zone.

The cold water which flows out when the hot water is removed is 
first routed to the storage tank at the very bottom of the heat ex-
changer, where it cools the lower area of the storage tank down 
as much as possible. The readiness zone is heated by an ex-
ternal heat generator (condensing boiler, heat pump, solar 
system, electric immersion heater). Water flows through the heat 
exchanger for storage charging (SL-WT) from top to bottom.

On its way to the top, the domestic water continuously absorbs 
the heat of the storage tank water. The flow direction, operating 
on the principle of counter-flow, and the coil-shaped heat ex-
changer create a pronounced temperature layering in the hot 
water storage tank. As high temperatures can be maintained for 
a very long time in the upper section of the storage tank, a high 
hot water output is achieved even if water is drawn off over a long 
period of time.

The Daikin high-performance-hot water storage tanks EKHWP / 
EKHWC can also be solar heated, in addition to by an external 
heat generator. Depending on the available heat from the sun, 
the entire hot water storage tank can be heated up. The stored 
heat is now used both for hot water generation and for heating 
support. The high total storage capacity also temporarily allows 
time without sunshine to be bridged.

If a Daikin heat pump system is used as an external heat gen-
erator, the primary hot water storage tank can only be one of the 
"hot water storage tanks for heat pump systems" listed in chap. 
3.1.1 or 3.1.2.

Optimum water hygiene

Low flow or unheated zones on the domestic water side are com-
pletely excluded with the Daikin high-performance-hot water 
storage tank. It is impossible for sludge, rust or other sediments 
to be deposited, as can be the case with other large volume 
tanks. The water which is fed into the system first is also dis-
charged first (first in, first out principle).

Low maintenance and corrosion

The Daikin high-performance hot water storage tank is made of 
plastic and is completely corrosion free. No sacrificial anode or 
similar corrosion protection system is necessary. This means that 
associated maintenance work, e.g. changing the protective 
anodes or cleaning the storage tank, does not need to be carried 
out on the Daikin high-performance-hot water storage tank. Only 
the fill level of the storage tank water needs to be checked.

The corrugated stainless steel pipe heat exchangers on the 
heating and potable water side are made from high quality 
stainless steel (1.4404).

Low scaling

On the storage tank side only one deposition of scale is possible. 
The immersion heater therefore remains clean, as do all the 
stainless steel heat exchanger pipes in the storage tank water. 
This means that no scale can build up which would continuously 
reduce the efficiency of heat transfer in the course of operation 
(as is the case with other storage tank designs).

The thermal and pressure expansion and high flow rates in the 
domestic water heat exchanger release any possible scale de-
posits, which are then flushed away.

Economical operation

The full area heat insulation of the storage tank ensures very low 
heat losses in use and means that the best use is made of the 
heat energy being applied.

Modular extension facility

If the heat output of a single Daikin high-performance hot water 
storage tank is not adequate you can modularly interconnect 
several storage tanks.

Electronic control

A control system integrated in the heat generator controls all 
heating and hot water functions for the direct heating circuit, a 
mixed heating circuit which can be connected as an option and a 
storage tank charging circuit.

3.3

Scope of delivery

– Daikin EKHWP / EKHWC / EKHWD hot water storage tank
– Bag of accessories (see fig. 3-5)

A

Carrier loops (only required 
for transport)

B

Cover screen

C

Hose connection piece for 
safety overflow

D

Spanner

Fig. 3-5

Content of bag of accessories

Summary of Contents for EKHWP300B

Page 1: ...y hot water storage tank Installation and operating instructions High efficiency hot water storage tank English EKHWP300B EKHWP300PB EKHWP500B EKHWP500PB EKHWDH500B EKHWDB500B EKHWC500B EKHWCH300B EKH...

Page 2: ......

Page 3: ...4 1 Electric immersion heaters 14 3 4 2 Non return valves 14 3 4 3 Dirt filters 14 3 4 4 Scalding protection 14 3 4 5 Solar storage tank extension kit 14 3 4 6 KFE filling connection 14 4 Set up and...

Page 4: ...experts who have experience in the proper installation and maintenance of heating systems and hot water storage tanks by virtue of their technical training and knowledge This manual provides all the n...

Page 5: ...he hazards involved This assumes knowledge and use of the con tents of this manual of the relevant accident pre vention regulations as well as the recognised safety related and occupational health rul...

Page 6: ...ing on the domestic water side Only original Daikin replacement parts may be used 2 4 2 Electrical installation of optional accessories Before beginning work on live parts disconnect them from the pow...

Page 7: ...revent possible damage fit a dirt filter or sludge separator into the heating return flow of the system SAS 1 2 4 6 Operation Only operate the Daikin EKHWP EKHWC EKHWD After all installation and conne...

Page 8: ...or 8 10 all 20 DrainBack solar return flow S B S D S H S J S Q Filling and draining connection for storage tank water all 21 DrainBack solar inflow 7 9 S B S D S H S J S Q 22 Pressurised solar return...

Page 9: ...ections and dimensions high performance hot water storage tank with solar support type EKHWP 300 500B 790 X 1 2 3 4 5 6 7 8 9 10 11 141 211 175 333 374 517 558 609 650 0 25 24 26 27 9 30 31 19 21 4 2...

Page 10: ...kin EKHWP EKHWC EKHWD Daikin High efficiency hot water storage tank 008 1618744 03 2017 3 x Product description Pressurised system Fig 3 2 Connections and dimensions high performance hot water storage...

Page 11: ...ions high performance hot water storage tank with solar support types EKHWC B EKHWD B 790 X 141 211 175 333 374 517 558 609 650 0 25 24 26 27 9 30 31 19 21 4 25 24 29 4 9 10 28 27 26 12 1 20 5 6 11 2...

Page 12: ...B 7 8 5 6 3 4 1 2 1 2 3 4 5 6 7 8 9 10 11 790 X 141 211 175 333 135 374 517 558 609 650 0 25 24 26 27 9 30 31 19 22 4 2 3 20 S K S L X 615 122 202 347 387 427 467 0 25 24 26 27 9 19 22 4 595 2 3 20 S...

Page 13: ...3 1 1 or 3 1 2 Optimum water hygiene Low flow or unheated zones on the domestic water side are com pletely excluded with the Daikin high performance hot water storage tank It is impossible for sludge...

Page 14: ...r sludge trap see Daikin price list 3 4 4 Scalding protection There is a danger of scalding at hot water temperatures over 60 C Fitting scalding protection enables the hot water temper ature to be var...

Page 15: ...Erect the Daikin EKHWP EKHWC EKHWD only at a minimum distance of 1 m to other heat sources 90 C e g electric heater gas heater chimney and flammable materials CAUTION Only erect the Daikin EKHWP EKHW...

Page 16: ...binet behind panels or in other restricted conditions sufficient ventilation e g using ventilation gratings must be ensured Fig 4 2 Install hot water storage tank shown on the EKHWP WARNING There is a...

Page 17: ...Establish the drainage connection on site EKHWP Use storage tank connection kit E PAC see price list 8 Establish connections to the heat generator EKHWC EKHWD Establish the connections to the heat gen...

Page 18: ...nection on the Daikin EKHWD Connect the filling hose with backflush prevention 1 2 to the previously installed KFE filling connection Fill the storage tank on the Daikin EKHWD until water comes out of...

Page 19: ...olar system on the filling and draining connection of the Daikin EKHWP EKHWC Connect the filling hose with backflush prevention 1 2 to the previously installed KFE filling connection Only with solar s...

Page 20: ...completely full it can lead to a reduction in performance of the electric heating tripping of the safety temperature limiter Operate the electric immersion heater booster heater only with the storage...

Page 21: ...n and activate the frost protection function or take the appropriate frost protection measures for the hot water storage tank e g by draining If there is a risk of frost for a few days only the excell...

Page 22: ...illing and draining connection 5 Unscrew the threaded piece fig 6 5 item E at the filling and draining connection remove the plug fig 6 5 item F and immediately screw in the pre assembled hose connect...

Page 23: ...1618744 03 2017 Installation and operating instructions 23 7 Hydraulic connection 7 1 Connection diagrams 7 1 1 Solution for low temperature heat pumps Fig 7 1 Standard connection layout with heat pum...

Page 24: ...HYW Low loss header MAG Diaphragm expansion vessel MIX 3 way mixer with drive motor MK1 Mixer group with high efficiency pump MK2 Mixer group with high efficiency pump PWM controlled P1 Central heatin...

Page 25: ...the solar panels Visual inspection of the general condition of the hot water storage tank Visual check of the water storage tank level filling level indicator Top up water if required see chapter 4 S...

Page 26: ...r capacity heat exchanger litres 11 0 Heat exchanger surface area m2 2 2 2 Storage tank charging heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres 10 9 Heat exchanger surface...

Page 27: ...Water capacity heat exchanger litres 11 3 Heat exchanger surface area m2 2 3 Pressurised solar heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres Heat exchanger surface area m...

Page 28: ...l 1 4404 Water capacity heat exchanger litres 11 3 Heat exchanger surface area m2 2 3 Pressurised solar heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres 4 2 12 5 Heat exchang...

Page 29: ...eel 1 4404 Water capacity heat exchanger litres 13 2 18 5 Heat exchanger surface area m2 2 7 3 8 Solar heating backup stainless steel 1 4404 Water capacity heat exchanger litres 2 3 Heat exchanger sur...

Page 30: ...3 8 Pressurised solar heat exchanger stainless steel 1 4404 Water capacity heat exchanger litres 4 2 12 5 Heat exchanger surface area m2 0 8 1 7 Solar heating backup stainless steel 1 4404 Water capa...

Page 31: ...ger 1 EKHWCH300B EKHWCH300PB e Heating support heat exchanger EKHWCH500B EKHWCH500PB EKHWCB500B EKHWCB500PB p mbar Pressure drop in millibar m L h Flow rate in litres per hour m L h Flow rate in litre...

Page 32: ...x Technical data 9 3 Tightening torque Name Thread size Tightening torque Hydraulic line connections Water 1 25 to 30 Nm Electric immersion heater booster heater 1 5 max 10 Nm hand tight Cabling on t...

Page 33: ...10 x Notes Daikin EKHWP EKHWC EKHWD Daikin High efficiency hot water storage tank 008 1618744 03 2017 Installation and operating instructions 33 10 Notes...

Page 34: ...Installation and operating instructions 34 Daikin EKHWP EKHWC EKHWD Daikin High efficiency hot water storage tank 008 1618744 03 2017 10 x Notes...

Page 35: ...ntrol 13 E PAC 6 15 17 29 Explanation of symbols 5 F Filling 18 Filling water 6 H Housing installation room 6 I Installation 15 K KFE filling connection 14 21 M Minimum distance 16 N Name plate 8 O Op...

Page 36: ...008 1618744_05 03 2017 Copyright Daikin...

Reviews: