Daikin EKHTSU200AA Installation Manual Download Page 6

 

Installation manual

 

4

 

EK260AA + EKUHWHTA

 

Domestic hot water tank with UK kit for air to water heat pump system

 

4PW53247-1B

 

I

 

NSTALLATION

 

 

 

OF

 

 

 

THE

 

 EKHTSU 

 

DOMESTIC

 

 

 

HOT

 

 

 

WATER

 

 

 

TANK

 

If required by relevant local and national regulations, connect a
recirculation pump in between the hot water end point and the
recirculation connection of the domestic hot water tank.

 

Installation guidelines

 

Keep in mind the following guidelines when installing the domestic
hot water tank:

 

 

The installation location is frost-free.

 

 

Standard installation location of the domestic hot water tank is
on top of the indoor unit.

 

 

The domestic hot water tank can be floor mounted as well. In
that case, the dedicated EKFMAHTA connection kit for
installation of the domestic hot water tank next to the indoor unit
is required and to be ordered separately.

 

 

Locate the domestic hot water tank in a suitable position to
facilitate ease of maintenance. Refer to the grey-coloured zones
indicated in the outlook diagram figure and to the installation
manual of the EKHBRD indoor unit.

 

 

To  avoid back siphonage it is advised to install a non-return
valve on the water inlet of the domestic hot water tank in
accordance with local and national regulations.

 

 

Take  care that in the event of a leak, water can not cause any
damage to the installation space and surroundings.

 

 

If installing an EKHTSU* domestic hot water tank, installing the
kit EKUHWHTA is obligatory. Refer to the UK Building
Regulation G3.

 

Installing and commisioning the domestic hot water tank

Installing the hot water tank on top of the indoor unit

 

1

 

Unpack the domestic hot water tank according to the
instructions mentioned on the unpacking instruction sheet.

 

2

 

Check if all domestic hot water tank accessories are enclosed
(see 

"Accessories" on page 2

).

 

3

 

Remove front and top plate of the indoor unit.

To  take away the front decoration panel, remove the 2 bottom
screws and then unhitch the panel.

Mount the top plate of the indoor unit on the domestic hot water
tank module.

 

4

Connect the 3-way valve

1

 

Remove drain plate on top of the
indoor unit before installing the
3-way valve.

 

2

 

Installation position.

The 3-way valve must be installed in the indoor unit.

 

3

 

Unpack the 3-way valve body and 3-way valve motor.

Verify that following accessories are provided with the motor.

 

 

Installation shall be done by a licensed technician, the
choice of materials and installation shall comply with
local and national regulations.

 

 

The equipment is not intended for use in a potentially
explosive atmosphere.

 

 

Domestic hot water quality must be according to EU
directive 98/83 EC.

 

 

For safety reasons, it is not allowed to add any kind of
glycol to the water circuit.

 

 

To  avoid stagnation of water, it is important that the
storage capacity of the domestic hot water tank meets
the daily consumption of domestic hot water.
In cases where during longer periods of time there is
no consumption of hot water, the equipment must be
flushed with fresh water before usage.
The disinfection function provided on the equipment is
specified in the operation manual of the indoor unit.

 

 

It is advised to avoid long runs of piping between the
domestic hot water tank and the hot water end point
(shower, bath, ...) and to avoid dead ends.

 

 

The installation must be in compliance with local and
national regulations and may require additional
hygienic installation measures.

 

 

For compliance with UK Building Regulations,
thermostatic mixing valves must be installed.

 

 

Immediately after installation, the domestic hot water
tank must be flushed with fresh water. This procedure
must be repeated at least once a day the first 5
consecutive days after installation.

 

If available service space to left and/or right side is
limited, carefully consider all indoor module
installation steps first.

3

4

1

2

1

Recirculation connection

2

Hot water connection

3

Shower

4

Recirculation pump

 

1

 

Sleeve

 

2

 

Valve motor cover

 

3

 

Screw

 

4

 

Turn knob

1

2

3

2x

1

1

1

2x

2x

2x

2x

4x

1

3

2

1

From indoor unit

2

To domestic hot water tank

3

To room heating

1

2

3

4

Summary of Contents for EKHTSU200AA

Page 1: ...INSTALLATION MANUAL EKHTSU200AA EKHTSU260AA EKUHWHTA Domestic hot water tank with UK kit for air to water heat pump system...

Page 2: ...5x 1x 1x 1x 1 3 6 7 5 2 4 1x 340 mm 11 10 12 12 13 2 1 5 4 6 8 3 9 1 2 7 772 902 1032 H 120 6 0 1156 778 653 694 443 600 300 5 B C 250 250 A 600 30 D 30 2x 8 9 6 1 2 1 2 5 9 3 5 9 3 7 6 10 10 4 10 4...

Page 3: ...ct to building regulation approval notify Local Authority of intention to install The EKHTSU domestic hot water tank can only be connected to a EKHBRD indoor unit The domestic hot water tank is availa...

Page 4: ...oupler 22 mm 15 mm 5 Expansion vessel of 18 litres 6 Tundish 7 Elbow Drain valve 22 mm x 3 4 Male BSP 8 Adaptor 22 mm x 3 4 Female BSP 9 T piece 22 mm x 22 mm x 22 mm 10 Instruction sheet 1x 1x 1x 1x...

Page 5: ...before opening the decoration panels of the indoor unit NOTE Refer to Installation of the EKUHWHTA kit on the domestic hot water tank on page 8 for connection of other safety devices in accordance wi...

Page 6: ...itch the panel Mount the top plate of the indoor unit on the domestic hot water tank module 4 Connect the 3 way valve 1 Remove drain plate on top of the indoor unit before installing the 3 way valve 2...

Page 7: ...ifted slightly manual operation is possible 8 Make sure to firmly fix the power supply cord onto the 3 way valve body with a field supplied cable tie like in illustration below 9 Perform the wiring in...

Page 8: ...t water tank on page 8 10 Connect the thermistor wire to the indoor unit switch box Make sure power supply is switched off Refer to the wiring diagram delivered with the indoor unit The distance betwe...

Page 9: ...re and pressure relief valve to ensure free water flow through the discharge pipe turn knob left Refer to Main components on page 2 for location of the temperature and pressure relief valve 13 Reattac...

Page 10: ...pipework All pipework must have a continuous fall Sizing of copper discharge pipe D2 for common temperature relief valve outlet sizes All pipework and fittings must be flushed free of all flux and de...

Page 11: ...ne strainer and the expansion relief valve parts 1 and 2 of this kit see also procedure step 2 as high as possible and connect it to the water mains inlet The expansion relief valve must be installed...

Page 12: ...sing and correcting certain troubles which may occur in the unit General guidelines Before starting the trouble shooting procedure carry out a thorough visual inspection of the unit and look for obvio...

Page 13: ...then contact your local dealer EKHTSU200AA EKHTSU260AA Storage capacity l 200 260 Material Stainless steel Stainless steel Overall dimensions h x l x w mm 1335 x 600 x 695 1610 x 600 x 695 Operating...

Page 14: ...4PW53247 1B Copyright Daikin...

Reviews: