background image

Installation and maintenance manual

18

 DAIKIN EKHHP(3/5)00AA2V3

DAIKIN Hot water heat pump

008.1423444_02 – 09/2015

x

 Decommissioning

4.1.2 Draining the hot water circuit

● Close the cold water supply to the DAIKIN EKHHP.
● Separate the cold water supply pipe to the DAIKIN EKHHP 

and allow the hot water distribution network to empty out.

● Isolate the cold water supply and hot water outlet from the 

DAIKIN EKHHP.

● Connect drain hoses to cold water supply and hot water outlet 

so that the end of the hose is located just above ground level.

● Allow heat exchanger to drain according to the siphon 

principle.

4.2 Final shutdown

A final shutdown may be necessary if
– the system is defective and is being dismantled and disposed 

of.

– components of the system are defective, are being disman-

tled and replaced.

– the system or parts of the system are being dismantled and 

reassembled in another location.

The DAIKIN EKHHP is designed to be environmentally friendly 
and easy to install: the jobs described above can therefore be 
carried out in an efficient and environmentally-friendly manner.

When changing location or replacing parts on the coolant system 
in the pipe network:
● Pump the coolant back into the external heat pump unit (see 

installation and operating guide for the particular external 
heat pump unit).

When disposing of the machine or replacing parts in the coolant 
system:

● Suction the coolant from the machine and recycle (see instal-

lation and operating guide for the particular external heat 
pump unit).

● Decommissioning a DAIKIN EKHHP (see section 4.1).
● Disconnect the DAIKIN EKHHP from all electrical connec-

tions, refrigerant and water connections.

● Dismantle the DAIKIN EKHHP or components in accordance 

with the installation guide in reverse order.

● DAIKIN EKHHP disposed off in a professional manner.

Recommendations for disposal

The DAIKIN EKHHP has an environmentally friendly design. 
During the disposal process, the only waste created is that which 
can be used for material or thermal recycling. The materials used 
that are suitable for recycling can be sorted into individual types.

WARNING!

Cooling systems (heat pumps), climate control 
systems and heating devices that are incorrectly dis-
mantled can both endanger the life and health of 
people and exhibit impaired function during start-up.

● Work on the DAIKIN EKHHP (such as dismantling 

components, temporary or final shutdown of 
system) is only to be carried out by persons who 
are authorised and who have successfully 
completed 

qualifying technical or vocational 

training 

for the specific activity and who have 

taken part in advanced training sessions recog-
nised by the relevant responsible authorities. 
These include, in particular, 

certified heating 

engineers, qualified electricians and HVAC 
specialists

, who on account of their 

professional 

training

 and 

expert knowledge

, have experience 

in the professional installation and maintenance of 
heating, cooling and air conditioning systems and 
heat pumps.

● You 

must observe 

the 

warning and safety 

instructions

 in the installation manual on working 

in the coolant system.

CAUTION!

Coolant escaping from the system causes long-term 
damage to the environment.

Mixing different kinds of coolant can result in hazard-
ous toxic gases being released. Mixing with oils when 
coolant escapes can lead to the soil being contami-
nated.

● Never allow coolant to be released into the atmos-

phere - always suction it off and recycle using a 
suitable recycling device.

● Always recycle coolant, in so doing keeping it 

separated from oils and other additives.

● Only store different types of coolant separately, in 

suitable pressure vessels.

● Dispose of coolants, oils and additives properly 

and in accordance with the applicable national 
regulations of the country it is being used in.

DAIKIN has complied with the standards for environ-
mentally-friendly disposal as a result of the environ-
mentally-friendly design of the DAIKIN EKHHP. Proper 
disposal in compliance with the respective national reg-
ulations of the country of use is the responsibility of the 
user/owner.

The designation of the product means that electrical 
and electronic products may not be disposed of 
together with unsorted domestic waste.

Proper disposal in compliance with the respective 
national regulations of the country of use is the respon-
sibility of the user/owner.

– Disassembly of the system, handling of coolant, 

oil and other parts may only be carried out by a 
qualified fitter.

– Disposal may only be carried out by an organi-

zation that specialises in reuse, recycling and 
recovery.

Further information is available from the installation 
company or the responsible local authorities.

Summary of Contents for EKHHP300AA2V3

Page 1: ...Installation and maintenance manual EKHHP300AA2V3 EKHHP500AA2V3 Hot water heat pump Installation and maintenance manual Hot water heat pump English...

Page 2: ...15 17...

Page 3: ...eater BOH switched on 13 Heat exchanger stainless steel for storage tank charging by Hot water heat pump liquifier 42 Display external signal HT LT Smard Grid 14 Heat exchanger stainless steel for sto...

Page 4: ...t controller Smart Grid SG 14 2 8 4 Optional External heat generator installation 14 3 Start up 15 3 1 Start up 15 3 1 1 Requirements 15 3 1 2 Start the system 16 4 Decommissioning 17 4 1 Temporary sh...

Page 5: ...al are classified according into their severity and probability of occurrence Special warning signs Some types of danger are represented by special symbols 1 2 2 Validity Some information in this manu...

Page 6: ...sts and climate control technicians who have experience as a result of their technical training and their knowledge of the subject of proper and appropriate installation and mainte nance of heating cl...

Page 7: ...e safety valve and the DAIKIN EKHHP Any steam or heating water which may escape must be diverted by a suitable blow off line with constant gradient in a frost protected safe and observable manner The...

Page 8: ...ting the user owner Before you hand over the DAIKIN EKHHP explain to the user owner how to operate and check the system Hand over the technical documentation this document and all supporting documents...

Page 9: ...professional installation and maintenance of heating cooling and air conditioning systems and heat pumps Component Thread size Tightening torque Hydraulic line connections water 1 25 to 30 Nm Liquid...

Page 10: ...HHP Create hydraulic connections on the DAIKIN EKHHP see fig 2 5 Take the position and dimensions of the connections from the overview image on page 2 and tab 0 1 on page 3 CAUTION If the DAIKIN EKHHP...

Page 11: ...the hood cut out WARNING There is a danger of scalding at hot water tem peratures over 60 C This is possible when solar energy is used with a connected external heating device when the Legionella prot...

Page 12: ...torque see section 2 1 Design the lines as such that the sound attenuation cowl can be applied without any problem following assembly 2 5 Laying coolant lines Check whether oil trap arc necessary Req...

Page 13: ...rsons who hold a certificate of competence for the European Region in accordance with the F Gas Regulation EC No 303 2008 Fill in the total coolant filling quantity on the supplied lable on the heat p...

Page 14: ...2 must be set If the EVU transmits the reduced tariff signal the switching contact HT LT is opened The installation switches to Reduced Mode If the signal is sent again the potential free switching c...

Page 15: ...roperly commissioned DAIKIN EKHHP can endanger the lives and health of persons and its function can be impaired The initial commissioning of the DAIKIN Hot water heat pump should only be carried out b...

Page 16: ...and no damage detected Yes 2 Minimum distance between the DAIKIN EKHHP and other sources of heat 80 C of 1 m Yes 3 Booster Heater Does the mains connection comply with the regulations and is the mains...

Page 17: ...t water Draining the storage tank only after it has cooled down for a long enough period with a suitable device for the safe draining or catching of escaping water wearing appropriate protective cloth...

Page 18: ...he life and health of people and exhibit impaired function during start up Work on the DAIKIN EKHHP such as dismantling components temporary or final shutdown of system is only to be carried out by pe...

Page 19: ...ay refrigerant compressor active This icon shows that the refrigerant compressor is active in the external heat pump unit 38 Display switching time programme switched on This icon shows that the timer...

Page 20: ...e only accessible to the specialist heating technician This security measure ensures that no undesirable malfunctions arise through incorrect configu ration 5 2 1 Switching the system on and off Press...

Page 21: ...r temperature When you press the key again the operating mode Automatic is switched off and the icon goes out 5 3 3 Low Noise Low noise mode means that the exterior heat pump unit is oper ating at red...

Page 22: ...e number 9 Use the and keys to set the starting time 10 By pressing the key you can select the type of switching for this switching time number 11 Confirm the switching time and switching type using t...

Page 23: ...in tab 5 5 The second and third number 03 show the relevant parameter in this group of parameters Code 2 in tab 5 5 1 Press key for at least 5 s The icon is displayed The current parameter code is di...

Page 24: ...lable 4 03 Simultaneous operation of the electrical Booster Heat ers BOH and the heat pump 0 Not possible 1 Is possible only when in operating mode Low Noise 2 Is possible only when in operating mode...

Page 25: ...exclusively heat pump mode the electrical Booster Heater BOH is switched in for hot water generation see fig 5 6 The following setting options are available 7 01 Switching hysteresis Booster Heater BO...

Page 26: ...e display of various different unit infor mation is the heat pump inside unit DAIKIN EKHHP No settings can be made for this parameter Fig 5 6 Control of hot water generation at high hot water set temp...

Page 27: ...erature 0 01 10 5 60 1 Min 3 00 Automatic restart after a power failure 1 0 1 1 01 Access authorisation 3 2 3 1 02 Hot water set temperature 60 C 0 0 1 1 4 03 Simultaneous operation of the electrical...

Page 28: ...temperature C C C C C TUE Switching time Action On Off ON OFF ON OFF ON OFF ON OFF ON OFF Feed temperature C C C C C WED Switching time Action On Off ON OFF ON OFF ON OFF ON OFF ON OFF Feed temperatu...

Page 29: ...hing times are being carried out at the wrong time Day of the week and time are not correctly set Set the weekday Set time Check week day switching time allocation Switching time function deactivated...

Page 30: ...th EKHHP 500 with optional external heat generator Optional external heat gener ator switched in but cannot guarantee ade quate heat delivery Check heat delivery by the optional auxiliary heater incre...

Page 31: ...ump device E6 Refrigerant compressor blocked E7 Fan block in the external heat pump unit E8 Flow rate too high in heat pump external unit EC Temperature in internal hot water tank is too high F3 The d...

Page 32: ...arding the coolant used The complete heat pump system contains refrigerant with fluorinated greenhouse gases which damage the environment if released Coolant type R410A GWP value 2087 5 GWP Global War...

Page 33: ...connection of the DAIKIN EKHHP see overview image on page 2 item 10 or With solar system Mount KFE filling connection accessory KFE BA on the connection bracket of the control and pump unit RPS3 Conn...

Page 34: ...area m2 1 7 Thermal perfor mance data1 Hot water quantity without re heating at a draw off rate of 12 l min TS 50 C litres 150 2 310 2 Hot water quantity without re heating at a flow rate of 12 l min...

Page 35: ...3G 1 phase 1 TCW Cold water input temperature 10 C TDHW Hot water draw off temperature 40 C TS Storage target temperature charge state before drawing off 2 Hot water storage tank only to be charged u...

Page 36: ...Installation and maintenance manual 36 DAIKIN EKHHP 3 5 00AA2V3 DAIKIN Hot water heat pump 008 1423444_02 09 2015...

Page 37: ...DAIKIN EKHHP 3 5 00AA2V3 DAIKIN Hot water heat pump 008 1423444_02 09 2015 Installation and maintenance manual 37...

Page 38: ...Installation and maintenance manual 38 DAIKIN EKHHP 3 5 00AA2V3 DAIKIN Hot water heat pump 008 1423444_02 09 2015...

Page 39: ...DAIKIN EKHHP 3 5 00AA2V3 DAIKIN Hot water heat pump 008 1423444_02 09 2015 Installation and maintenance manual 39...

Page 40: ...008 1423444_02 09 2015 Copyright Daikin...

Reviews: