11. DISPOSAL
At the end of use, the heat pumps must be disposed of in com-
pliance with current regulations.
ATTENTION!: This equipment contains fluori
-
nated greenhouse gases included in the Kyoto
protocol. Maintenance and disposal operations
must be carried out only by qualified personnel.
INFORMATION FOR USERS
Pursuant to Directives 2011/65/EU and 2012/19/
EU on the restriction of the use of hazardous sub-
stances in electrical and electronic equipment, as
well as the disposal of waste.
The crossed-out bin symbol on the equipment or
on its packaging indicates that, at the end of its useful life, the
product must be collected separately from other waste.
Therefore, at the end of its life, the user must give the equip-
ment to the appropriate recycling centers for electrical and
electronic equipment, or return it to the dealer when purchasing
new, equivalent type equipment, on a one-to-one basis.
Adequate separate waste collection for subsequent sending of
the decommissioned equipment to environmentally compatible
recycling, treatment and/or disposal helps prevent negative ef-
fects on the environment and health and favors the reuse and/
or recycling of the materials that make up the equipment.
Unauthorized disposal of the product by the user involves the
application of the administrative sanctions provided for by cur-
rent legislation.
The main materials that make up the equipment in ques-
tion are:
• steel
• magnesium
• plastic
• copper
• aluminum
• polyurethane
12. PRODUCT SHEET
Descriptions
u.m. EKHHE200CV37 EKHHE260CV37 EKHHE200PCV37 EKHHE260PCV37
Declared load profile
-
L
XL
L
XL
Water heater thermostat temperature settings
°C
55
55
55
55
Water heating energy efficiency class
(1)
-
A+
A+
A+
A+
Water heating energy efficiency -
h
wh
(1)
%
135
138
135
138
COP
DHW
(1)
-
3.23
3.37
3.23
3.37
Annual electricity consumption - AEC
(1)
kWh
761
1210
761
1210
Water heating energy efficiency -
h
wh
(2)
%
106
112
106
112
COP
DHW
(2)
-
2.55
2.73
2.55
2.73
Annual electricity consumption - AEC
(2)
kWh
944
1496
944
1496
Water heating energy efficiency -
h
wh
(3)
%
162
160
162
160
COP
DHW
(3)
-
3.89
3.9
3.89
3.9
Annual electricity consumption - AEC
(3)
kWh
631
1046
631
1046
Indoor sound power level
(4)
dB (A)
53
51
53
51
Outdoor sound power level
(4)
dB (A)
45
44
45
44
The water heater can work during off-peak hours only
-
NO
NO
NO
NO
Any specific precautions that shall be taken when the water heater is
assembled, installed or maintained
-
See manual
(1):
Data according to EN 16147: 2017 standard for AVERAGE climate (unit in ECO mode; Inlet water = 10 ° C; Inlet air temp = 7 ° C DB / 6 ° C WB)
(2):
Data according to EN 16147: 2017 standard for COLDER climate (unit in ECO mode; Inlet water = 10 ° C; Inlet air temp = 2 ° C DB / 1 ° C WB)
(3):
Data according to EN 16147: 2017 standard for WARMER climate (unit in ECO mode; Inlet water = 10 ° C; Inlet air temp = 14 ° C DB / 13 ° C WB)
(4):
Data according to EN 12102-2: 2019 ECO mode with Inlet air temp = 7 ° C DB / 6 ° C WB