Installation manual
39
EKHBH/X008BB
Indoor unit for air to water heat pump system
4PW62570-1A – 01.2011
8.10. Field settings table
(1)
(1) When the unit is configured for restricted power supply condition mode,
see
First
code
Second
code
Setting name
Installer setting at variance with default value
Default
value
Range
Step
Unit
Date
Value
Date
Value
0
User permission level
00
User permission level
3
2/3
1
—
1
Weather dependent set point
00
Low ambient temperature (Lo_A)
–10
–20~5
1
°C
01
High ambient temperature (Hi_A)
15
10~20
1
°C
02
Set point at low ambient temperature (Lo_Ti)
40
25~55
1
°C
03
Set point at high ambient temperature (Hi_Ti)
25
25~55
1
°C
05
Weather dependent for cooling function
enable/disable
0 (OFF)
0/1
—
—
06
Low ambient temperature (Lo2_A)
20
10~25
1
°C
07
High ambient temperature (Hi2_A)
35
25~43
1
°C
08
Set point at low ambient temperature (Lo2_Ti)
22
5~22
1
°C
09
Set point at high ambient temperature (Hi2_Ti)
18
5~22
1
°C
2
Disinfection function
00
Operation interval
Fri
Mon~Sun, All
—
—
01
Status
1 (ON)
0/1
—
—
02
Start time
23:00
0:00~23:00
1:00
hour
03
Set point (only in combination with domestic hot
water tank
without
electrical booster heater
(EKHTS), [4-03]=5)
60
fixed
5
°C
03
Set point (only in combination with domestic hot
water tank
with
built-in electrical booster heater
(EKHW*), [4-03]
≠
5)
70
55~80
5
°C
04
Interval (only in combination with domestic hot
water tank
without
electrical booster heater
(EKHTS), [4-03]=5)
60
40~60
5
min
04
Interval (only in combination with domestic hot
water tank
with
built-in electrical booster heater
(EKHW*), [4-03]
≠
5)
10
5~60
5
min
3
Auto restart
00
Status
0 (ON)
0/1
—
—
4
Backup/booster heater operation and space heating off temperature
00
Backup heater operation (only in combination with
domestic hot water tank
without
electrical booster
heater (EKHTS)
1 (ON)
0/1/2
—
—
00
Backup heater operation (only in combination with
domestic hot water tank
with
built-in electrical
booster heater (EKHW*))
1 (ON)
0/1
—
—
01
Backup/booster heater priority
0 (OFF)
0/1/2
—
—
02
Space heating off temperature
25
14~25
1
°C
03
Booster heater operation (only in combination with
domestic hot water tank
without
electrical booster
heater (EKHTS))
5
fixed
—
—
03
Booster heater operation (only in combination with
domestic hot water tank
with
built-in electrical
booster heater (EKHW*))
3
0/1/2/3/4
—
—
04
Not applicable.
—
—
—
—
05
Not applicable.
—
—
—
—
06
Backup heater emergency operation
1 (enabled)
0/1
1
—
07
Backup heater second step
1 (enabled)
0/1
1
—