4 Setting the energy prices

Operation manual

8

EHYH EHYHBH/X08AA

Daikin Altherma hybrid heat pump

4P349588­1 – 2013.05

3.7

Installer settings: Tables to be
filled in by installer

3.7.1

Quick wizard

Setting

Default

Fill in…

Preferential kWh rate power supply [A.2.1.6]

Preferential kWh rate

0 (No)

Space heating/cooling settings [A.2.1]

Unit control method

2 (RT control)

User interface location

0 (At unit)

Number of LWT zones

0 (1 LWT
zone)

Pump operation mode

1 (Sample)

Domestic hot water settings [A.2.2]

DHW operation

Depends on
model

DHW pump

0 (No)

Thermostats [A.2.2]

Contact type main

2 (H/C
request)

Contact type add.

2 (H/C
request)

External sensor

0 (No)

Digital I/O PCB [A.2.2.6]

Ext. backup heat src

0 (No)

Solar kit

0 (No)

Alarm output

0 (Normally
open)

Bottom plate heater

0 (No)

Demand PCB [A.2.2.7]

Demand PCB

0 (No)

Energy metering [A.2.2]

External kWh meter 1

0 (No)

Gas meter

0 (No)

3.7.2

Space heating/cooling control

Setting

Default

Fill in…

Leaving water temperature: Main zone [A.3.1.1]

LWT setpoint mode

1 (Weather
dep.)

Set weather­dependent heating

25/40/15/−10

Set weather­dependent cooling

18/22/35/20

Leaving water temperature: Additional zone [A.3.1.2]

LWT setpoint mode

0 (Fixed)

Set weather­dependent heating

35/45/15/−10

Set weather­dependent cooling

8/22/35/20

Leaving water temperature: Delta T emitter [A.3.1.3]

Heating

5°C

Cooling

5°C

Leaving water temperature: Modulation [A.3.1.1.5]

Modulated LWT

0 (No)

Leaving water temperature: Emitter type [A.3.1.1.7]

Emitter type

1 (Slow)

Savings mode [A.6.7]

Savings mode

0
(Economical)

Setting

Default

Fill in…

Fuel price [7.4.6]

Fuel price

8.0/kWh

Electricity price [7.4.5]

Elec price

20/kWh (High)

20/kWh
(Medium)

15/kWh (Low)

3.7.3

Domestic hot water control [A.4]

Setting

Default

Fill in…

Type

2 (Scheduled
only)

Setpoint readout type

0
(Temperature)

Maximum setpoint

Depends on
model

INFORMATION

When  the  DHW  tank  booster  mode  is  active,  the  risk  of
space  heating/cooling  and  capacity  shortage  comfort
problems  is  significant.  In  case  of  frequent  domestic  hot
water  operation,  frequent  and  long  space  heating/cooling
interruptions will happen.

3.7.4

Contact/helpdesk number [6.3.2]

Setting

Default

Fill in…

Contact/helpdesk number

4

Setting the energy prices

If your system's savings mode is set to Economical, it allows you to
set:

▪ a fixed gas price

▪ 3 electricity price levels

▪ a weekly schedule timer for electricity prices.

The  savings  mode  is  set  by  the  installer.  Refer  to  the  installation
manual for more information.

4.1

To set the gas price

1

Go to [7.4.6]: 

 > User settings > Preset values > Fuel price.

2

Use 

 and 

 to set the correct price.

3

Press 

 to confirm.

INFORMATION

▪ Price  value  ranging  from  0.00~290  valuta/MBtu  (with  2

significant values).

▪ Price  value  ranging  from  0.00~990  valuta/kWh  (with  2

significant values).

4.2

To set the electricity price

1

Go to [7.4.5]: 

 > User settings > Preset values > Elec price.

2

Use 

 and 

 to set the correct prices for High, Medium and

Low, according to your electricity tariff.

3

Press 

 to confirm.

Summary of Contents for EHYHBH05AA

Page 1: ...Operation manual Daikin Altherma hybrid heat pump English Operation manual Daikin Altherma hybrid heat pump EHYHBH05AA EHYHBH08AA EHYHBX08AA ...

Page 2: ...ance Request the installer to inform you about the settings that he used to configure your system Check if he has filled in the installer settings tables If not request him to do so Keep the documentation for future reference Target audience End users Documentation set This document is part of a documentation set The complete set consists of Document Contains Format General safety precautions Safe...

Page 3: ... the menu structure e NAVIGATING CHANGING SETTINGS Navigates the cursor on the display Navigates through the menu structure Changes settings Selects a mode f OK Confirms a selection Enters a submenu in the menu structure Switches between displaying actual and desired values or between displaying actual and offset values if applicable on the home pages Goes to the next step when you are programming...

Page 4: ... between home pages go to User settings Display User profile User profile Basic User profile Detailed 20 0 C 1 5 2 0 A c t u a l t e m p e r a t u r e Mon Room 20 0 C 1 5 2 0 1 7 3 0 A c t u a l t e m p e r a t u r e Scheduled Tue Mon Room To read out the actual and desired room temperature 1 Go to the room temperature home page Room Result You can read out the actual temperature 20 0 C A c t u a ...

Page 5: ...ent and long space heating cooling interruptions will happen Scheduled mode In scheduled mode the DHW tank produces hot water corresponding to a schedule The best time to allow the tank to produce hot water is at night because The space heating demand is lower Electricity tariffs are lower Example t 60 C 00 00 07 00 50 C 15 C 40 C 14 00 21 00 1 2 3 4 5 Tt Tt DHW tank temperature t Time Scheduled r...

Page 6: ... 5 1 To program the schedule 1 Go to 7 3 1 1 User settings Set schedules Room temp Set heating schedule 2 Select Empty and press 3 Program the schedule for Monday See below for more details 4 Copy from Monday to Tuesday Wednesday Thursday and Friday See below for more details 5 Program the schedule for Saturday 6 Copy from Saturday to Sunday 7 Save the schedule and give it a name See below for mor...

Page 7: ...ation 6 Display Temperature lock Set schedules Preset values User settings 7 Allowed operation mode Unit of measurement Holiday Holiday mode From Until Holiday 2 Operation mode Away Heating Cooling Consumed elec Produced energy Energy metering 6 2 Error history Contact helpdesk number Error information 6 3 Contrast Backlit LCD time User profile Available home pages Display 7 1 Room temperature LWT...

Page 8: ...on A 3 1 1 5 Modulated LWT 0 No Leaving water temperature Emitter type A 3 1 1 7 Emitter type 1 Slow Savings mode A 6 7 Savings mode 0 Economical Setting Default Fill in Fuel price 7 4 6 Fuel price 8 0 kWh Electricity price 7 4 5 Elec price 20 kWh High 20 kWh Medium 15 kWh Low 3 7 3 Domestic hot water control A 4 Setting Default Fill in Type 2 Scheduled only Setpoint readout type 0 Temperature Max...

Page 9: ...kly schedule for your normal space heating or cooling needs If necessary you can easily deviate from the schedule For shorter periods You can overrule the scheduled room temperature Example When you have a party or when you are leaving for a couple of hours For longer periods You can use the holiday mode Example When you stay at home during your holiday or when you go away during your holiday Tips...

Page 10: ...f the problems recurs daily do one of the following Increase the DHW tank temperature preset value Adjust the DHW tank temperature schedule Example Program to additionally heat up the DHW tank to a preset value Storage eco lower tank temperature during the day The desired DHW tank temperature is too low The instant DHW temperature is too low Only applicable when no tank is installed Increase the i...

Page 11: ......

Page 12: ...4P349588 1 2013 05 Copyright 2013 Daikin ...

Reviews: