![Daikin EHS157056 Installation And Operation Manual Download Page 2](http://html.mh-extra.com/html/daikin/ehs157056/ehs157056_installation-and-operation-manual_501787002.webp)
[
]
RoCon G1 - EHS157056
[
]
RoCon G1 - EHS157056
2/24
KA RoCon G1 - EHS157056 . 07/2019 . 008.1550899 00 - EN
Intended use
Scope of delivery
Gateway connections
The installation of RoCon G1 Gateway must always be carried out by professional staff who are trained in the installation
and commissioning of electrical devices.
Only operate the device in interior spaces and avoid the influence of humidity, dust as well as insolation and heat radiation.
Any other use which is not described in this installation manual is not an intended use and leads to the exclusion of
warranty and liability. This also applies to conversions and alterations. The device is exclusively intended for private use.
Assembly and commissioning
RoCon G1 Gateway can be mounted to the wall or
operating in an upright position. For wall mounting use the
corresponding holding brackets on the casing.
1
Connection of power supply unit
2
LAN network Connection
3
bus connection for RoCon control
4
Status LED
Picture 1: Connections RoCon G1
Picture 2: Wall mounting
1
2
3
4
50 mm
The following sequence must be adhered to during set-up and commissioning:
Connection to RoCon control
During the connection to the RoCon control the Gateway should be switched off. Insert the bus cable supplied into the
corresponding bushing on the side of the Gateway and set up the connection to the RoCon control (see image 3).
Connection to network via LAN
Connect the RoCon G1 Gateway with a router. Insert the network cable into the corresponding specific
bushing of the
LAN
Gateway and a free network socket at the installation site. If there is no
network available, often a connection to the router
LAN
can be established using a power
adapter. In this case contact a company specialising in network installation.
LAN
RoCon G1 Gateway
Central Control Unit
Power supply unit Gateway
5V
Mains cable
Mains cable RoCon control
Documentation
Brief installation guide