3 Installation
Installation manual
11
EHBH/X04~16CA
Daikin Altherma - Low Temperature Split
4P313771-1C – 2012.11
X1M
X2M
5
6
7
M2S
X1M
X2M
5
6 7
M2S
NO
NC
2
Fix the cable with cable ties to the cable tie mountings.
3.5.7
To connect the electrical meters
INFORMATION
In case of an electrical meter with transistor output, check
the polarity. The positive polarity MUST be connected to
X5M/7 and X5M/9; the negative polarity to X5M/8 and
X5M/10.
1
Connect the electrical meters cable to the appropriate terminals
as shown in the illustration below.
X2M
X5M
78 910
S2S S3S
2
Fix the cable with cable ties to the cable tie mountings.
3.5.8
To connect the domestic hot water pump
1
Connect the domestic hot water pump cable to the appropriate
terminals as shown in the illustration below.
X2M
35
34
1~
M
M2P
2
Fix the cable with cable ties to the cable tie mountings.
3.5.9
To connect the alarm output
1
Connect the alarm output cable to the appropriate terminals as
shown in the illustration below.
X1M
X2M
29
X1
M
YC
Y1
Y2
Y3
Y4
A4P
X2M
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
3.5.10
To connect the space cooling/heating
ON/OFF output
1
Connect the space cooling/heating ON/OFF output cable to the
appropriate terminals as shown in the illustration below.
X1M
X2M
29
X1
M
YC
Y1
Y2
Y3
Y4
A4P
X2M
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
3.5.11
To connect the changeover to external
heat source
1
Connect the changeover to external heat source cable to the
appropriate terminals as shown in the illustration below.
X1M
X1
M
X3 X4
A4P
L N
X2M
X1 X2
a
a
Installation of EKRP1HB is required.
2
Fix the cable with cable ties to the cable tie mountings.
3.5.12
To connect the power consumption digital
inputs
1
Connect the power consumption digital inputs cable to the
appropriate terminals as shown in the illustration below.