3 Installation
Installation manual
10
EHBH/X04~16CA
Daikin Altherma - Low Temperature Split
4P313771-1C – 2012.11
5
Cut off a 2 wire conductor.
6
Connect the wires to the user interface as shown below.
From the rear
b
a
PCB
1x
a
Notch this part for the wiring to pass through with
nippers etc.
b
Secure the wiring to the front part of the casing
using the wiring retainer and clamp.
7
Reinstall the faceplate onto the wallplate.
Fixation of the user interface to the wall in case of installation
as room thermostat
8
Insert a screwdriver into the slots underneath the user interface
and carefully separate the faceplate from the wallplate.
NOTICE
The PCB is mounted in the faceplate of the user interface.
Be careful NOT to damage it.
9
Fix the wallplate of the user interface to wall.
10
Connect the wires to the user interface as shown below.
From the rear
b
a
PCB
1x
From the left
a
PCB
b
1x
From the top
a
b
PCB
b
1x
From the top center
a
PCB
b
b
1x
a
Notch this part for the wiring to pass through with
nippers etc.
b
Secure the wiring to the front part of the casing
using the wiring retainer and clamp.
11
Reinstall the faceplate onto the wallplate.
3.5.6
To connect the shut-off valve
1
Connect the valve control cable to the appropriate terminals as
shown in the illustration below.
NOTICE
Wiring is different for a NC (normal closed) valve and a NO
(normal open) valve.