background image

6 Commissioning

Installation manual

20

EGSQH10S18AA9W

Daikin Altherma ground source heat pump

4P351747-1F – 2016.06

6

Commissioning

NOTICE

NEVER  operate  the  unit  without  thermistors  and/or
pressure  sensors/switches.  Burning  of  the  compressor
might result.

6.1

Checklist before commissioning

Do NOT operate the system before the following checks are OK:

You  read  the  complete  installation  instructions,  as
described in the 

installer reference guide

.

The 

indoor unit

 is properly mounted.

The following 

field wiring

 has been carried out according

to this document and the applicable legislation:

▪ Between the local supply panel and the indoor unit

▪ Between the indoor unit and the valves (if applicable)

▪ Between  the  indoor  unit  and  the  room  thermostat  (if

applicable)

The  system  is  properly 

earthed

  and  the  earth  terminals

are tightened.

The 

fuses

  or  locally  installed  protection  devices  are

installed  according  to  this  document,  and  have  not  been
bypassed.

The 

power  supply  voltage

  matches  the  voltage  on  the

identification label of the unit.

There  are  NO 

loose  connections

  or  damaged  electrical

components in the switch box.

There  are  NO 

damaged  components

  or 

squeezed

pipes

 on the inside of the indoor unit.

There are NO 

refrigerant leaks

.

The  correct  pipe  size  is  installed  and  the 

pipes

  are

properly insulated.

There  is  NO 

water  and/or  brine  leak

  inside  the  indoor

unit.

There are no 

odour traces

 noticeable of the used brine.

The 

space  heating  air  purge

  valve  is  open  (at  least  2

turns).

The 

pressure relief valves

 purge to a safe location when

opened.

The 

minimum  water  volume

  is  guaranteed  in  all

conditions. See "To check the water volume and flow rate
of  the  space  heating  circuit  and  brine  circuit"  in

"3.2 Preparing piping" on page 4

.

INFORMATION

The  software  is  equipped  with  an  "installer-on-site"  mode
([4‑0E]),  that  disables  automatic  operation  by  the  unit.  At
first  installation,  setting  [4‑0E]  is  by  default  set  to  "1",
meaning  automatic  operation  is  disabled.  All  protective
functions  are  then  disabled.  If  the  user  interface  home
pages  are  off,  the  unit  will  NOT  operate  automatically.  To
enable  automatic  operation  and  the  protective  functions,
set [4‑0E] to "0".

12 hours after the first power-on, the unit will automatically
set  [4‑0E]  to  "0",  ending  "installer-on-site"  mode  and
enabling  the  protective  functions.  If  –  after  first
installation  –  the  installer  returns  to  the  site,  the  installer
has to set [4‑0E] to "1" manually.

6.2

Checklist during commissioning

The 

minimum  flow  rate

  during  backup  heater/defrost

operation  is  guaranteed  in  all  conditions.  See  "To  check
the water volume and flow rate of the space heating circuit
and brine circuit" in 

"3.2 Preparing piping" on page 4

.

To perform an 

air purge

.

To perform an 

air purge on the brine circuit

.

To perform a 

test run

.

To perform an 

actuator test run

.

Underfloor screed dryout function

The  underfloor  screed  dryout  function  is  started  (if
necessary).

6.2.1

To check the minimum flow rate

1

Confirm  according  to  the  hydraulic  configuration  which  space
heating  loops  can  be  closed  due  to  mechanical,  electronic,  or
other valves.

2

Close all space heating loops that can be closed (see previous
step).

3

Start  the  pump  test  run  operation  (see 

"6.2.5  To  perform  an

actuator test run" on page 21

).

4

Go to [6.1.8]: 

 > Information > Sensor information > Flow rate

to check the flow rate. During pump test run operation, the unit
can operate below this minimum required flow rate.

Bypass valve foreseen?

Yes

No

Modify the bypass valve setting
to reach the minimum required
flow rate + 2 l/min

In case the actual flow rate is
below the minimum flow rate,
modifications at the hydraulic
configuration are required.
Increase the space heating loops
that can NOT be closed or install
a pressure‑controlled bypass
valve.

Minimum required flow rate during backup heater operation

12 l/min

6.2.2

To perform an air purge

Prerequisite: 

Make  sure  that  the  leaving  water  temperature  home

page, room temperature home page, and domestic hot water home
page are turned OFF.

1

Go  to  [A.7.3]: 

  >  Installer  settings  >  Commissioning  >  Air

purge.

2

Set the type.

3

Select Start air purge and press 

.

4

Select OK and press 

.

Result: 

The  air  purge  starts.  It  stops  automatically  when  done.  To

stop it manually, press 

, select OK and press 

.

6.2.3

Air purge function on the brine circuit

When  installing  and  commissioning  the  unit,  it  is  very  important  to
remove all air from the brine circuit.

NOTICE

It  is  required  that  the  brine  circuit  is  filled  BEFORE  the
brine pump test run is activated.

Summary of Contents for EGSQH10S18AA9W

Page 1: ...Installation manual Daikin Altherma ground source heat pump English Installation manual Daikin Altherma ground source heat pump EGSQH10S18AA9W ...

Page 2: ... souladu s našimi pokyny odpovídají následujícím normám nebo normativním dokumentům u skladu sa slijedećim standardom ima ili drugim normativnim dokumentom ima uz uvjet da se oni koriste u skladu s našim uputama 16 17 18 19 20 21 22 23 24 25 megfelelnek az alábbi szabvány ok nak vagy egyéb irányadó dokumentum ok nak ha azokat előírás szerint használják spełniają wymogi następujących norm i innych ...

Page 3: ...on 14 5 1 1 To access the most used commands 14 5 2 Basic configuration 15 5 2 1 Quick wizard Language time and date 15 5 2 2 Quick wizard Standard 15 5 2 3 Quick wizard Options 15 5 2 4 Quick wizard Capacities energy metering 16 5 2 5 Space heating control 17 5 2 6 Domestic hot water control 18 5 2 7 Contact helpdesk number 18 5 3 Advanced configuration optimization 18 5 3 1 Space heating operati...

Page 4: ... heating circuit and brine circuit Minimum water volume Check that the total water volume per circuit in the installation is minimum 20 litre the internal water volume of the indoor unit NOT included INFORMATION If a minimum heating load of 1 kW can be guaranteed and setting 9 04 is changed by the installer from 1 to 4 C the minimum water volume can be lowered to 10 litre INFORMATION In critical p...

Page 5: ... d a Refer to name plate on unit b Minimum cable section 0 75 mm c Cable section 2 5 mm d Cable section 0 75 mm till 1 25 mm maximum length 50 m Voltage free contact shall ensure the minimum applicable load of 15 V DC 10 mA e Cable section 0 75 mm till 1 25 mm maximum length 500 m Applicable for both single user interface and dual use interface connection NOTICE More technical specifications of th...

Page 6: ...2 NOTICE Do NOT throw away any bolts They need to be re inserted when transport or heavy manipulation is required 5 Open the front plate of the unit If needed the nylon bands for lifting can be used 6 Adjust the height of the 4 leveling feet of the outer frame to compensate for floor irregularities The maximum allowed deviation is 1 1 NOTICE To avoid structural damage on unit ONLY move the unit wh...

Page 7: ...ircuit WARNING Before during and after filling carefully check the brine circuit for leakage WARNING Temperature of the fluid running through the evaporator can become negative It MUST be protected against freezing Refer to setting A 04 in 5 2 2 Quick wizard Standard on page 15 INFORMATION The materials used in the units brine circuit are chemically resistant to the following anti freeze fluids 40...

Page 8: ...ondensate can form on the brine components inside the compressor department of the unit The unit contains a drain pan Depending on room ambient temperature room humidity and operation condition the drain pan can overflow A drain hose is supplied with the unit The drain hose is routed to the backside on the left close to the bottom of the unit A field supplied drain pump might be needed to pump the...

Page 9: ...duced by equipment connected to public low voltage systems with input current 16 A and 75 A per phase 4 5 2 To connect the electrical wiring on the indoor unit INFORMATION Foresee additional cable length of 35 cm for all wires which should be connected to X2M and X5M on sheet metal support above the hydro PCB Additional wire length should be tie wrapped at the back side of the unit Reason is to gu...

Page 10: ...r ambient temperature sensor Indoor ambient temperature sensor option Electrical meters field supply Safety thermostat field supply b High voltage power supply Normal kWh rate power supply power supply for unit c High voltage control signal Preferential kWh rate power supply Heat pump convector option Room thermostat option Shut off valve field supply Domestic hot water pump field supply Alarm out...

Page 11: ...installation manual of the sensor delivered as accessory 4 5 5 To connect the user interface If you use 1 user interface you can install it at the indoor unit for control close to the indoor unit or in the room when used as room thermostat If you use 2 user interfaces you can install 1 user interface at the indoor unit for control close to the indoor unit 1 user interface in the room used as room ...

Page 12: ... electrical meters INFORMATION In case of an electrical meter with transistor output check the polarity The positive polarity MUST be connected to X5M 7 and X5M 9 the negative polarity to X5M 8 and X5M 10 1 Connect the electrical meters cable to the appropriate terminals as shown in the illustration below X2M X5M 6 8910 7 S2S S3S 2 Fix the cable with cable ties to the cable tie mountings 4 5 8 To ...

Page 13: ...below X2M X5M A8P S6S S7S S8S S9S 1 2 3 4 5 a a Installation of EKRP1AHTA is required 2 Fix the cable with cable ties to the cable tie mountings 4 5 13 To connect the safety thermostat normal closed contact 1 Connect the safety thermostat normal closed cable to the appropriate terminals as shown in the illustration below X2M X5M 3 4 2 Fix the cable with cable ties to the cable tie mountings INFORM...

Page 14: ...umb in the menu structure Accessing settings via the code in the overview settings Code See also To access the installer settings on page 14 5 4 Menu structure Overview installer settings on page 19 5 1 1 To access the most used commands To access the installer settings 1 Set the user permission level to Installer 2 Go to A Installer settings To access the overview settings 1 Set the user permissi...

Page 15: ...ation 0 At unit 1 In room default Code Description A 2 1 8 7 02 Number of water temperature zones 0 1 LWT zone Main 1 2 LWT zones Main additional A 2 1 9 F 0D Pump operation 0 Continuous Continuous pump operation regardless of thermo ON or OFF condition 1 Sample default When thermo OFF condition occurs the pump runs every 5 minutes and the water temperature is checked If the water temperature is b...

Page 16: ... send a thermo ON OFF condition A 2 2 B C 08 External sensor 0 No default NOT installed 2 Room sensor Connected to PCB measuring the indoor temperature Digital I O PCB Code Description A 2 2 6 1 C 02 External backup heater source 0 No default None 1 Bivalent Gas oil boiler Code Description A 2 2 6 3 C 09 Alarm output on optional EKRP1HB PCB 0 Normally open default The alarm output will be powered ...

Page 17: ...and leaving water In case a minimum temperature difference is required for the good operation of the heat emitters in heating mode Leaving water temperature Modulation Code Description A 3 1 1 5 8 05 Leaving water temperature modulation 0 No Disabled 1 Yes Enabled The leaving water temperature is calculated according to the difference between desired and actual room temperature This allows better ...

Page 18: ...t protection NOTICE If Emergency is set to Manual A 6 C 0 and the unit is triggered to start emergency operation the user interface will ask confirmation before starting Room frost protection is active even if the user does NOT confirm emergency operation 5 3 2 Heat source settings Auto emergency When the heat pump fails to operate the backup heater can serve as an emergency heater and either auto...

Page 19: ...location Options Contact type main Contact type add Digital I O PCB Demand PCB External kWh meter External kWh meter DHW pump External sensor Leaving water Main Additional Delta T source Room thermostat Room temp range Room temp offset Ext room sensor offset Operation range Space heating OFF temp Disinfection Disinfection Operation day Start time Temperature target Duration Backup heater Operation...

Page 20: ... functions set 4 0E to 0 12 hours after the first power on the unit will automatically set 4 0E to 0 ending installer on site mode and enabling the protective functions If after first installation the installer returns to the site the installer has to set 4 0E to 1 manually 6 2 Checklist during commissioning The minimum flow rate during backup heater defrost operation is guaranteed in all conditio...

Page 21: ...sioning tasks are finished 1 Start the brine pump test run and leave it on for at least 3 seconds Result A 60 second timer starts counting down 2 Stop the brine pump test run before the timer has finished Result A 30 second timer starts counting down 3 Start the brine pump test run again and leave it on for at least 3 seconds 4 Stop it before the timer has finished Result 10 day brine pump operati...

Page 22: ...e Checklist before commissioning room frost protection will be automatically disabled for 12 hours after the first power on If the screed dryout still needs to be performed after the first 12 hours of power on manually disable room frost protection by setting 2 06 to 0 and KEEP it disabled until the screed dryout has finished Ignoring this notice will result in cracking of the screed NOTICE For th...

Page 23: ... OFF VALVE SHUT OFF VALVE SHUT OFF VALVE 3 WAY VALVE indoor BACK UP HEATER Water side Refrigerant PRESSURE GAUGE SAFETY VALVE BLOW OFF indoor check valve Outlet Water Temperature Sensor LWC After BUH Temperature Sensor Refrigerant Liquid Temperature Sensor Inlet Water Temperature Sensor EWC DHW Tank Temperature Sensor Ambient Air Sensor discharge sensor suction sensor brine entering water brine le...

Page 24: ...s On OFF thermostat PC power circuit A8P Demand PCB A9P Main PCB refrigerant brine A10P Main PCB inverter CN A4P Connector DS1 A8P DIP switch F1U F2U A4P Fuse 5 A 250 V K R Relay on PCB M2P Domestic hot water pump M2S Shut off valve Q DI Earth leakage circuit breaker R1T A3P Ambient sensor On OFF thermostat R1T A9P Ambient air sensor R2T A3P External sensor floor or ambient R6T A1P External indoor...

Page 25: ...trical meters For safety thermostat For safety thermostat Inrush Inrush current Max load Maximum load Normally closed Normally closed English Translation Normally open Normally open Safety thermostat contact 16 V DC detection voltage supplied by PCB Safety thermostat contact 16 V DC detection voltage supplied by PCB Shut off valve Shut off valve SWB Switch box 7 External room thermostats and heat ...

Page 26: ... for heat pump convector Only for KRTR wireless room thermostat Only for KRTW wired room thermostat Space heating On OFF output Electricity meter pulse input 2 Electricity meter pulse input 1 Circulation pump for DHW main zone shut off valve Ext heat source eg boiler alarm indication 4 core 2 core 2 core 2 core 2 core signal 2 core signal 2 core 2 core communication 2 core 2 core 2 core 2 core 2 c...

Page 27: ......

Page 28: ...4P351747 1 F 00000002 4P351747 1F 2016 06 Copyright 2013 Daikin ...

Reviews: