• Indoor Unit • 4-way blow ceiling suspended unit • FUQ-C

1

2

• Split -  Sky Air  • Indoor Unit

4

2

Specifications

Standard Accessories : Drain hose;
Standard Accessories : Declaration of conformity;
Standard Accessories : Operation manual;
Standard Accessories : Installation manual;
Standard Accessories : Clamp metal;
Standard Accessories : Washer for hanger bracket;
Standard Accessories : Clamps;
Standard Accessories : Washer clamp;
Standard Accessories : Joint insulation & Sealing material;
Standard Accessories : Elbow;
Standard Accessories : Installation pattern;
Standard Accessories : Blocking material;
Standard Accessories : L-bent piping;
Standard Accessories : Screws;
Standard Accessories : Non woven fabric;

Sound pressure level

Cooling

High/Nom./Low

dBA

41/38/35

46/42/39

47/43/40

Heating

Super high/High/
Nom./Low

dBA

-/41/38/35

-/46/42/39

-/47/43/40

Refrigerant

Type

R-410A

Piping connections

Sound absorbing insulation

Not needed

Liquid

Type/OD

mm

C1220T (Flare connection)/9.52

Gas

Type/OD

mm

C1220T (Flare connection)/15.9

Drain

VP25 (OD Ø32.0)

Heat insulation

Needed

Air direction control

Up and downwards

Air filter

Type

Resin net with mold resistance

Quantity

pc

1

Drain-up height

mm

600

2-2 Electrical Specifications

FUQ7 1C

FU Q100 C

FUQ12 5C

Power supply

Name

VE

Phase

1~

Frequency

Hz

50/60

Voltage

V

220-240/220

Current - 50Hz

Maximum running current

A

0.9

1.3

1.4

Current - 60Hz

Nominal running current

A

-

2-1 Technical Specifications

FUQ7 1C

FU Q100 C

FUQ12 5C

Summary of Contents for EEDEN13-100

Page 1: ...Air Conditioning Technical Data 4 way blow ceiling suspended unit EEDEN13 100 FUQ C...

Page 2: ......

Page 3: ...tions 3 Electrical Specifications 4 3 Safety device settings 5 Safety Device Settings 5 4 Options 6 Options 6 5 Dimensional drawings 7 Dimensional Drawings 7 6 Piping diagrams 8 Piping Diagrams 8 7 Wi...

Page 4: ...closed via the wired remote controller BRC1E52 in case you would refurbish or rearrange your interior Setup to 3 independent schedules so the user can easilychange the schedule himself throughout the...

Page 5: ...e Hi XA Tube material Copper Tube diameter mm 5 0 Fin Type Multi slit fin Treatment Anti Corrosion Hydrophilic Fan Type Turbo fan Quantity 1 Air flow rate Cooling High m min 23 31 32 5 cfm 812 1 095 1...

Page 6: ...andard Accessories Screws Standard Accessories Non woven fabric Sound pressure level Cooling High Nom Low dBA 41 38 35 46 42 39 47 43 40 Heating Super high High Nom Low dBA 41 38 35 46 42 39 47 43 40...

Page 7: ...3 1 3 Split Sky Air Indoor Unit 5 Indoor Unit 4 way blow ceiling suspended unit FUQ C 3 Safety device settings 3 1 Safety Device Settings...

Page 8: ...Indoor Unit 4 way blow ceiling suspended unit FUQ C 1 4 Split Sky Air Indoor Unit 6 4 Options 4 1 Options...

Page 9: ...3 1 5 Split Sky Air Indoor Unit 7 Indoor Unit 4 way blow ceiling suspended unit FUQ C 5 Dimensional drawings 5 1 Dimensional Drawings...

Page 10: ...Indoor Unit 4 way blow ceiling suspended unit FUQ C 1 6 Split Sky Air Indoor Unit 8 6 Piping diagrams 6 1 Piping Diagrams...

Page 11: ...3 1 7 Split Sky Air Indoor Unit 9 Indoor Unit 4 way blow ceiling suspended unit FUQ C 7 Wiring diagrams 7 1 Wiring Diagrams Single Phase...

Page 12: ...Indoor Unit 4 way blow ceiling suspended unit FUQ C 1 8 Split Sky Air Indoor Unit 10 8 External connection diagrams 8 1 External Connection Diagrams...

Page 13: ...3 1 9 Split Sky Air Indoor Unit 11 Indoor Unit 4 way blow ceiling suspended unit FUQ C 9 Sound data 9 1 Sound Pressure Spectrum...

Page 14: ......

Page 15: ...ED EN13 100 1 1 12 Cop yrigh t Da ikin The p resen t pu bli cation su perse des EEDEN 12 1 00 The present leaflet is drawn up byway ofinformati on only and does not constitute an offer binding upon Da...

Reviews: