9
|
Electrical installation
Installer reference guide
113
EBLA04~E23V3 + EDLA04~E23V3
Daikin Altherma 3 M
4P685228-1A – 2022.05
7 9
YC
Y1
X2M
1
2
3
A4P
1+2
Wires connected to the alarm output
3
Wire between X2M and A4P
A4P
Installation of EKRP1HBAA is
required.
X2M.7
A4P.Y1
180°
X2M
YC Y1
A4P
X1M
a
9
7
YC Y1
X2M.9
a
Installation of EKRP1HBAA is required.
WARNING
Stripped wire.
Make sure that stripped wire cannot make contact with possible
water on the bottom plate.
3
Fix the cable with cable ties to the cable tie mountings.
9.2.10 To connect the space cooling/heating ON/OFF output
INFORMATION
Cooling is only applicable in case of reversible models.
Wires: (2+1)×0.75 mm²
Maximum load: 0.3 A, 250 V AC
—
1
Access the electrical connections. See
"9.2.1 To connect the electrical wiring
2
Connect the space cooling/heating ON/OFF output cable to the appropriate
terminals as shown in the illustration below.