2
|
General operation
Service manual
16
EBLA04~08E + EDLA04~08E
Daikin Altherma 3 M
ESIE22-09 – 2022.05
2 General operation
The low temperature monoblock is a Heat Pump system used for domestic heating
and/or cooling applications and can be combined with a domestic hot water tank.
Outdoor units
The outdoor unit consists of:
▪
Inverter compressor
▪
A switchbox containing necessary PCBs to control the refrigerant part
▪
A hydro box containing all PCBs and hydraulic parts to control the space heating/
cooling and optional domestic hot water preparation
▪
An air cooled heat-exchanger with inverter controlled fan
▪
A refrigerant to water heat exchanger with PWM controlled pump
▪
Expansion valve
▪
2 space heating connections (Water IN and Water Out)
▪
System is controlled via MMI2 room interface
Heating mode
The compressor capacity step is defined by the condensing temperature, which is
calculated through the high pressure sensor read-out.
In defrost or oil return operation the heat exchanger functions as a condenser,
while its fan motor is stopped.
Cooling mode
The compressor capacity step is defined by the evaporation temperature, which is
calculated through the low pressure sensor read-out.