Operation manual

7

E(D/B)(H/L)Q011~0W1

Unit for air to water heat pump system

4PW57622-1

Schedule timer operation

In schedule timer operation, the installation is controlled by the
schedule timer. The actions programmed in the schedule timer will be
executed automatically.

The schedule timer always follows the last command until a new
command is given. This means that the user can temporarily overrule
the last executed programmed command by manual operation (Refer
to 

"Manual operation" on page 6

). The schedule timer will regain

control over the installation as soon as the next programmed
command of the schedule timer occurs.

The schedule timer is enabled (

p

 icon displayed) or disabled (

p

 icon

not displayed), by pressing the 

pr

 button.

To set up the SCHEDULE TIMER refer to chapter 

"Programming and

consulting the schedule timer" on page 8

.

What can the schedule timer do?

The schedule timer allows the programming of:

1.

Space heating and space cooling (refer to 

"Programming space

cooling or space heating" on page 8

)

Switch on the desired mode at a scheduled time, in combination
with a set point (weather dependent or manually set). Five
actions per weekday can be programmed, totalling 35 actions.

2.

Quiet mode (refer to 

"Programming quiet mode, booster heating

or domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

3.

Booster heating (refer to 

"Programming quiet mode, booster

heating or domestic water heating" on page 9

)

Allow or disallow booster heating at a scheduled time. Five
actions can be programmed per mode. These actions are
repeated daily.

4.

Domestic water heating (refer to 

"Programming quiet mode,

booster heating or domestic water heating" on page 9

)

Switch the mode on or off at a scheduled time. Five actions can
be programmed per mode. These actions are repeated daily.

What can the schedule timer NOT do?

The schedule timer can not change the operation mode from space
cooling to space heating or vice versa.

How to interpret the programmed actions

To be able to understand the behaviour of your installation when the
schedule timer is enabled, it is important to keep in mind that the
"last" programmed command overruled the "preceding" programmed
command and will remain active until the "next" programmed
command occurs.

Example: imagine the actual time is 17:30 and actions are
programmed at 13:00, 16:00 and 19:00. The "last" programmed
command (16:00) overruled the "previous" programmed command
(13:00) and will remain active until the "next" programmed command
(19:00) occurs.

So in order to know the actual setting, one should consult the last
programmed command. It is clear that the "last" programmed
command may date from the day before. Refer to 

"Consulting

programmed actions" on page 10

.

Only use the 

pr

  button to enable or disable the

schedule timer. The schedule timer overrules the 

y

button. The 

y

  button only overrules the schedule

timer until the next programmed action.

If the auto restart function is disabled, the schedule
timer will not be activated when power returns to the
unit after a power supply failure. Press the 

pr

 button

to enable the schedule timer again.

When power returns after a power supply failure, the
auto restart function reapplies the user interface
settings at the time of the power supply failure.

It is therefore recommended to leave the auto restart
function enabled.

The programmed schedule is time driven. Therefore, it
is essential to set the clock and the day of the week
correctly. Refer to 

"Setting the clock" on page 5

.

Manually adjust the clock for summertime and
wintertime. Refer to 

"Setting the clock" on page 5

.

A power failure exceeding 2 hours will reset the clock
and the day of the week. The schedule timer will
continue operation, but with a disordered clock. Refer
to 

"Setting the clock" on page 5

  to adjust the clock

and the day of the week.

The actions programmed in the schedule timer will not
be lost after a power failure so that reprogramming the
schedule timer is not required.

NOTE

When the unit is connected to an external room
thermostat, the schedule timer for space cooling and
space heating is overruled by the external room
thermostat.

The programmed actions are not stored according to
their timing but according to the time of programming.
This means that the action that was programmed first
gets action number 1, even though it is executed after
other programmed action numbers.

When the schedule timer switches space heating or
space cooling 

x

, the controller will also be

switched off. Note that this has no influence on
domestic water heating.

During schedule timer operation, someone may have
altered the actual settings manually (in other words, the
"last" command was overruled manually). The icon 

p

,

indicating the schedule timer operation, may still be
displayed, giving the impression that the "last" command
settings are still active. The "next" programmed command
will overrule the altered settings and return to the original
program.

Summary of Contents for EBHQ011BA6V3

Page 1: ...DHQ016BA6W1 EDLQ011BA6V3 EDLQ014BA6V3 EDLQ016BA6V3 EDLQ011BA6W1 EDLQ014BA6W1 EDLQ016BA6W1 EBHQ011BA6V3 EBHQ014BA6V3 EBHQ016BA6V3 EBHQ011BA6W1 EBHQ014BA6W1 EBHQ016BA6W1 EBLQ011BA6V3 EBLQ014BA6V3 EBLQ016BA6V3 EBLQ011BA6W1 EBLQ014BA6W1 EBLQ016BA6W1 Unit for air to water heat pump system ...

Page 2: ...ly units The monoblock unit range consists of two main versions a heating cooling EB version and a heating only ED version Both versions are delivered with an integrated backup heater for additional heating capacity during cold outdoor temperatures The backup heater also serves as a backup in case of malfunctioning of the unit and for freeze protection of the outside water piping during winter tim...

Page 3: ...room thermostat connected to the unit This will prevent excessive space heating and will stop the unit and the circulation pump when the room temperature is above the thermostat set point Next recommendations only apply to installations with an optional domestic hot water tank Make sure the domestic hot water is only heated up to the domestic hot water temperature you require Start with a low dome...

Page 4: ...ive 3 OPERATION MODE ICONS hcws These icons indicate the current operation mode s space heating h space cooling c domestic water heating w or quiet mode s Within limits different modes can be combined e g space heating and domestic water heating The corresponding mode icons will be displayed simultaneously In a heating only installation the c icon will never be displayed If the domestic hot water ...

Page 5: ...ce purposes only Refer to the installation manual 25 SPACE HEATING COOLING BUTTON This button allows manual switching between cooling or heating mode provided the unit is not a heating only unit When the unit is connected with an external room thermostat this button is not operable and the icon e is shown 26 DOMESTIC WATER HEATING BUTTON v This button enables or disables heating of the domestic wa...

Page 6: ...r tank by heat pump when the space heating space cooling operation has reached its temperature set point or heat pump domestic water heating has a higher demand request than space side depends on DIP switch setting When necessary and when allowed by the booster heater schedule timer refer to Programming quiet mode booster heating or domestic water heating on page 9 the booster heater provides auxi...

Page 7: ... v for 5 seconds to activate powerful domestic water heating operation Icons w and m start flashing Powerful domestic water heating is deactivated automatically when the set point for the domestic hot water is reached Selecting quiet mode operation s 1 Use the s button to activate quiet mode operation s Icon s appears on the display If the controller is set in permission level 2 or 3 refer to Fiel...

Page 8: ...mmed at 13 00 16 00 and 19 00 The last programmed command 16 00 overruled the previous programmed command 13 00 and will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the day before Refer to Consulting programmed actions on page 10 Only use...

Page 9: ...oint Conversely when programming cooling actions time and setpoint heating actions are added automatically at the same time but with the default heating set point The set points of these automatically added actions can be adjusted by programming the corresponding mode This means that after programming heating you should also program the corresponding cooling set points and vice versa Programming P...

Page 10: ...store the programmed actions If the button is pressed when action number 3 is displayed actions 1 2 and 3 are stored but 4 and 5 are deleted You automatically return to step 6 By pressing the pr button several times you return to previous steps in this procedure and finally return to normal operation Programming quiet mode booster heating or domestic water heating Programming domestic water heatin...

Page 11: ...is possible to copy all programmed actions of a specific day to the next day e g copy all programmed actions from 1 to 2 To copy programmed actions to the next day proceed as follows 1 Press the button The actual mode is blinking 2 Use the pi and pj buttons to select the mode you want to program The selected mode is blinking You can leave programming by pressing the pr button 3 Press the button to...

Page 12: ...p 2 through 4 to change other field settings as required 7 When finished press the z button to exit FIELD SET MODE Detailed description 0 User permission level If required certain user interface buttons can be made unavailable for the user Three permission levels are defined see the table below Switching between level 1 and level 2 3 is done by simultaneously pressing buttons pfi and pfj immediate...

Page 13: ... whether the disinfection function is turned on 1 or off 0 2 02 Start time time of the day at which the domestic water should be heated 2 03 Set point high water temperature to be reached 2 04 Interval time period defining how long the set point temperature should be maintained 3 Auto restart When power returns after a power supply failure the auto restart function reapplies the user interface set...

Page 14: ...his setting Leave it set to its default value C Setup on EKRP1HB digital I O PCB Solar priority mode C 00 Solar priority mode setting for information concerning the EKSOLHW solar kit refer to the installation manual of that kit D Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent s...

Page 15: ...ace heating off temperature 35 14 35 1 C 03 Installation related setting 04 Installation related setting 5 Installation related settings 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Installation related setting 04 Installation related setting 6 Installation related settings 00 Installation related setting 01 Installation related setting 02 Inst...

Page 16: ...lated setting 04 Installation related setting D Local shift value weather dependent 00 Installation related setting 01 Installation related setting 02 Installation related setting 03 Local shift value weather dependent 0 0 1 2 3 4 E Unit information readout 00 Software version Read only 01 EEPROM version Read only 02 Unit model identification Read only 03 Liquid refrigerant temperature Read only C...

Page 17: ...fied installer in accordance with relevant local and national legislation Units must be treated at a specialized treatment facility for re use recycling and recovery By ensuring this product is disposed off correctly you will help to prevent potential negative consequences for the environment and human health Please contact the installer or local authority for more information DANGER Do not touch ...

Page 18: ...NOTES NOTES ...

Page 19: ......

Page 20: ...Copyright Daikin 4PW57622 1 ...

Reviews: