Tips and tricks
Programming the next day(s)
After con
fi
rming the programmed actions of a speci
fi
c day (i.e. after
pressing the
<
button for 5 seconds), press the
pr
button once. You
can now select another day by using the
pi
and
pj
buttons
and restart consulting and programming.
Copying programmed actions to next day
In heating/cooling program it is possible to copy all programmed
actions of a speci
fi
c day to the next day (e.g. copy all programmed
actions from "
1
" to "
2
").
To copy programmed actions to the next day, proceed as follows:
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to program.
The selected mode is blinking.
You can leave programming by pressing the
pr
button.
3
Press the
<
button to con
fi
rm the selected mode.
The actual day is blinking.
4
Select the day you would like to copy to the next day by means
of the
pi
and
pj
buttons.
The selected day is blinking.
You can return to step
by pressing the
pr
button.
5
Press the
<
and
pr
buttons simultaneously for 5 seconds.
After 5 seconds the display will show the next day (e.g. "
2
" if
"
1
" was selected
fi
rst). This indicates that the day has been
copied.
You can return to step
by pressing the
pr
button.
Deleting one or more programmed actions
Deleting one or more programmed actions is done at the same time
as storing the programmed actions.
When all actions for one day have been programmed, make sure that
the display shows the highest action number you would like to save.
By pressing the
<
button for 5 seconds, you store all actions except
those with a higher action number than the one that is displayed.
E.g. when the
<
button is pressed when action number 3 is
displayed, actions 1, 2 and 3 are stored but 4 and 5 are deleted.
Deleting a mode
1
Press the
<
button.
The actual mode is blinking.
2
Use the
pi
and
pj
buttons to select the mode you want
to delete (quiet mode
s
, booster heating
m
or domestic water
heating
w
).
The selected mode is blinking.
3
Press the
<
and
ba
button simultaneously for 5 seconds to
delete the selected mode.
Deleting a day of the week (cooling or heating mode)
1
Use the
=
button to select the operation mode (cooling or
heating) you want to delete.
2
Press the
<
button.
The actual mode is blinking.
3
Press the
<
button to con
fi
rm the selected mode.
The actual day is blinking.
4
Select the day you would like to delete by means of the
pi
and
pj
buttons.
The selected day is blinking.
5
Press the
<
and
ba
button simultaneously for 5 seconds to
delete the selected day.
4.3.
Field settings
The indoor unit shall be con
fi
gured by the installer to match the
installation environment (outdoor climate, installed options, etc.) and
user demand. However, the
fi
eld settings mentioned in
can be modi
fi
ed to customer preferences. Thereto,
a number of so called
fi
eld settings are available. These
fi
eld settings
are accessible and programmable through the user interface on the
indoor unit.
Each
fi
eld setting is assigned a 3-digit number or code, for example
[1-03], which is indicated on the user interface display. The
fi
rst digit
[1] indicates the '
fi
rst code' or
fi
eld setting group. The second and
third digit [03] together indicate the 'second code'.
A list of all
fi
eld settings and default values is given under
. In this same list, we provided for 2
columns to register the date and value of altered
fi
eld settings at
variance with the default value.
A detailed description of each
fi
eld setting is given under
Procedure
To change one or more
fi
eld settings, proceed as follows.
1
Press the
z
button for a minimum of 5 seconds to enter FIELD
SET MODE.
The
$
icon (3) will be displayed. The current selected
fi
eld
setting code is indicated
;
(2), with the set value displayed to
the right
-
(1).
2
Press the
bgi
button to select the appropriate
fi
eld setting
fi
rst code.
3
Press the
bgj
button to select the appropriate
fi
eld setting
second code.
4
Press the
pfi
button and
pfj
button to change
the set value of the select
fi
eld setting.
NOTICE
The default values mentioned in
are the values from factory. The actual initial
values shall be selected according to your application.
These values shall be con
fi
rmed by your installer.
CAUTION
The
fi
eld settings [2] depends on the relevant local and
national regulations.
The
fi
eld settings [9] depends on the application.
Before changing these settings, the new values shall be
con
fi
rmed by the installer and/or shall be according to the
local and national regulations.
2
3
1
Summary of Contents for EBHQ006BAV3
Page 19: ......