Printed Circuit Board Connector Wiring Diagram
SiAU18-715
48
Printed Circuit Board Connector Wiring Diagram
1.6
Floor / Ceiling Suspended Dual Type
Connectors
PCB(1) (Control PCB)
PCB(2) (Power Supply PCB)
PCB(3) (Display PCB)
PCB(4) (Signal Receiver PCB)
Note:
Other designations
PCB(1) (Control PCB)
PCB(2) (Power Supply PCB)
PCB(3) (Display PCB)
PCB(4) (Signal Receiver PCB)
1)
S6
Connector for swing motor (horizontal swing)
2)
S7
Connector for AC fan motor
3)
S21
Connector for
centralized control
4)
S24
Connector for display PCB
5)
S26
Connector for signal receiver PCB
6)
S32
Connector for heat exchanger thermistor
7)
S37
Connector for power supply PCB
1)
S36
Connector for control PCB
1)
S25
Connector for control PCB
1)
S27
Connector for control PCB
2)
S31
Connector for room temperature thermistor
1)
JA
Address setting jumper
JB
Fan speed setting
when compressor is OFF on thermostat
JC
Power failure recovery function
∗
Refer to page 163 for detail.
2)
SW2
Select switch ceiling or floor
3)
LED A
LED for service monitor (green)
1)
V1
Varistor
1)
FU1
Fuse (3.15A)
1)
LED1
LED for operation (green)
2)
LED2
LED for timer (yellow)
3)
LED3
LED for HOME LEAVE operation (red)
1)
SW1 (S1W)
Forced operation ON/OFF switch
Summary of Contents for E Series
Page 1: ...SiAU18 715 Applied Models Super Multi Plus Cooling Only Super Multi Plus Heat Pump E Series ...
Page 87: ...Refrigerant Flow for Each Operation Mode SiAU18 715 74 Refrigerant Circuit ...
Page 139: ...Indoor Unit SkyAir Models SiAU18 715 126 Function ...
Page 177: ...Test Operation and Field Setting for RA Indoor Unit SiAU18 715 164 Test Operation ...
Page 299: ...Instruction SiAU18 715 286 Operation Manual 2 6 Ceiling Suspended Type ...
Page 326: ...SiAU18 715 Service Check Function Troubleshooting 313 ...
Page 423: ...Method of Replacing The Inverter s Power Transistors Modules SiAU18 715 410 Troubleshooting ...
Page 443: ...Wiring Diagrams SiAU18 715 430 Appendix ...
Page 449: ...SiAU18 715 vi Index ...