background image

S

pecificatioNS

DM80HS

0403A*A

DM80HS

0603A*A

DM80HS

0604B*A

DM80HS

0803B*A

DM80HS

0804B*A

DM80HS

0805C*A

DM80HS

1005C*A

DM80HS

1205D*A

DM80HS

1405D*A

Heating Capacity
Input¹

40,000

60,000

60,000

80,000

80,000

80,000

100,000

120,000

140,000

Natural Gas Output¹

32,000

48,000

48,000

64,000

64,000

64,000

80,000

96,000

112,000

LP Gas Output¹

32,000

48,000

48,000

64,000

64,000

64,000

80,000

96,000

96,000

AFUE²

80

80

80

80

80

80

80

80

80

Available AC @ 0.5” ESP

3

3

4

3

4

5

5

5

5

Temperature Rise  

Range (°F)

25 - 55

20 - 50

20 - 50

35 - 65

35 - 65

35 - 65

35 - 65

40 - 70

40 - 70

Circulator Blower
Size (D x W)

10” x 6”

10” x 6”

10” x 8”

10” x 8”

10” x 8”

10” x 10”

10” x 10”

11” x 10”

11” x 10”

Horsepower @1075 RPM

½

½

½

½

¾

¾

Available Blower Speeds

4

4

4

4

4

4

4

4

4

Vent Diameter³

4"

4"

4"

4"

4"

4"

4"

4"

4"

No. of Burners

2

3

3

4

4

4

5

6

6

Disposable Filter (in

2

)*

356

610

610

569

569

569

711

776

960

Electrical Data
Min. Circuit Ampacity

4

8.1

8.1

12.5

8.1

12.5

12.5

12.5

14.7

14.7

Max. Overcurrent  

Device (amps)

5

15

15

15

15

15

15

15

15

15

Ship Weight (lbs)

86

90

98

106

107

114

118

132

132

1

  Natural Gas BTU/h; for altitudes above from 0’ to 5,500’ above sea level, reduce input rating 4% for each  

1,000’ above 5,500’ altitude. Low-fire rate is 75% of high-fire rate.

2

  DOE AFUE based upon Isolated Combustion System (ICS)

3

  Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas  

Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1  

and CAN/CSA B142.2 (in Canada).

4

  Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined  

in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.

5

  Refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit  

breakers of the same size as noted.

  * Permanent air filter size is based on 600 FPM velocity. Check with filter manufacturer for specific details.

N

oteS

• 

All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.

• 

Gas Service Connection ½” FPT

• 

Important: Size fuses and wires properly and make electrical connections in accordance with  

the National Electrical Code and/or all existing local codes.

P

roduct

 S

PecificationS

2

www.daikincomfort.com

SS-DM80HS

SS-DM80HS

www.daikincomfort.com

3

Wiring is subject to change. Always

 

refer to the wiring diagram or the

 

unit for the most up-to-date wiring.

  

W

arning

High V

oltage:

 

Disconnect all power before servicing or installing this unit. Multiple power

  

sources may be present. Failure to do so may cause property damage, personal injury

, or death.

Summary of Contents for DM80HS

Page 1: ...with provisions for electronic air cleaner and humidifier Low continuous fan speed options offer quiet air circulation California Low NOx emissions standards models available Cabinet Features Multi po...

Page 2: ...Stage Maximum CFM 3 1200 CFM Motor 4 1600 CFM C Variable Speed ComfortNet 5 2000 CFM E High Efficiency S Single Speed MBTU h 040 40 000 BTU h 060 60 000 BTU h 140 140 000 BTU h M Modulating H Converti...

Page 3: ...5 of high fire rate 2 DOE AFUE based upon Isolated Combustion System ICS 3 Vent diameter may vary depending upon vent length Refer to the latest editions of the National Fuel Gas Code NFPA 54 ANSI Z22...

Page 4: ...M80HS1005C A 21 19 DM80HS0604B A 17 16 DM80HS1205D A 24 23 DM80HS0803B A 17 16 DM80HS1405D A 24 23 DM80HS0804B A 17 16 Notes Line voltage wiring can enter through the right or left side of furnace Low...

Page 5: ...382 Med Lo 3 5 1 615 37 1 592 37 1 556 38 1 516 39 1 470 40 1 405 1 346 1 235 Low 3 1 290 46 1 285 46 1 265 47 1 235 48 1 214 49 1 174 1 044 904 DM80HS 1005C A High 5 2 323 2 225 2 120 35 2 040 36 1...

Page 6: ...CFM 800 Temperature Rise Output BTU h x 1 000 Formulas BTU h Output CFM x 1 08 x Rise Rise BTU H Output CFM x 1 08 BTU Output Vs Temperature Rise Chart Product Specifications 6 www daikincomfort com S...

Page 7: ...HES OPEN HIGH LIMIT 3 FLASHES PRESSURE SWITCH STUCK OPEN 2 FLASHES PRESSURE SWITCH STUCK CLOSED STEADY ON NORMAL OPERATION OFF CONTROL FAILURE 5 1 FLASH 0 1 2 3 4 PU 6 FLASHES OPEN ROLLOUT OR OPEN FUS...

Page 8: ...ry Vent Kit for DM80HS1205D and DM80HS1405D models only AFE18 60A Fossil Fuel Kit FTK04 Twinning Kit White Rodgers and Honeywell valves Upflow applications only Product Specifications 8 www daikincomf...

Reviews: