S
pecificatioNS
DM80HS
0403A*A
DM80HS
0603A*A
DM80HS
0604B*A
DM80HS
0803B*A
DM80HS
0804B*A
DM80HS
0805C*A
DM80HS
1005C*A
DM80HS
1205D*A
DM80HS
1405D*A
Heating Capacity
Input¹
40,000
60,000
60,000
80,000
80,000
80,000
100,000
120,000
140,000
Natural Gas Output¹
32,000
48,000
48,000
64,000
64,000
64,000
80,000
96,000
112,000
LP Gas Output¹
32,000
48,000
48,000
64,000
64,000
64,000
80,000
96,000
96,000
AFUE²
80
80
80
80
80
80
80
80
80
Available AC @ 0.5” ESP
3
3
4
3
4
5
5
5
5
Temperature Rise
Range (°F)
25 - 55
20 - 50
20 - 50
35 - 65
35 - 65
35 - 65
35 - 65
40 - 70
40 - 70
Circulator Blower
Size (D x W)
10” x 6”
10” x 6”
10” x 8”
10” x 8”
10” x 8”
10” x 10”
10” x 10”
11” x 10”
11” x 10”
Horsepower @1075 RPM
⅓
⅓
½
⅓
½
½
½
¾
¾
Available Blower Speeds
4
4
4
4
4
4
4
4
4
Vent Diameter³
4"
4"
4"
4"
4"
4"
4"
4"
4"
No. of Burners
2
3
3
4
4
4
5
6
6
Disposable Filter (in
2
)*
356
610
610
569
569
569
711
776
960
Electrical Data
Min. Circuit Ampacity
4
8.1
8.1
12.5
8.1
12.5
12.5
12.5
14.7
14.7
Max. Overcurrent
Device (amps)
5
15
15
15
15
15
15
15
15
15
Ship Weight (lbs)
86
90
98
106
107
114
118
132
132
1
Natural Gas BTU/h; for altitudes above from 0’ to 5,500’ above sea level, reduce input rating 4% for each
1,000’ above 5,500’ altitude. Low-fire rate is 75% of high-fire rate.
2
DOE AFUE based upon Isolated Combustion System (ICS)
3
Vent diameter may vary depending upon vent length. Refer to the latest editions of the National Fuel Gas
Code NFPA 54/ANSI Z223.1 (in the USA) and the Canada National Standard of Canada, CAN/CSA B149.1
and CAN/CSA B142.2 (in Canada).
4
Minimum Circuit Ampacity = (1.25 x Circulator Blower Amps) + ID Blower amps. Wire size should be determined
in accordance with National Electrical Codes. Extensive wire runs will require larger wire sizes.
5
Refers to maximum recommended fuse or circuit breaker size. May use fuses or HACR-type circuit
breakers of the same size as noted.
* Permanent air filter size is based on 600 FPM velocity. Check with filter manufacturer for specific details.
N
oteS
•
All furnaces are manufactured for use on 115 VAC, 60 Hz, single-phase electrical supply.
•
Gas Service Connection ½” FPT
•
Important: Size fuses and wires properly and make electrical connections in accordance with
the National Electrical Code and/or all existing local codes.
P
roduct
S
PecificationS
2
www.daikincomfort.com
SS-DM80HS
SS-DM80HS
www.daikincomfort.com
3
Wiring is subject to change. Always
refer to the wiring diagram or the
unit for the most up-to-date wiring.
⚠
W
arning
High V
oltage:
Disconnect all power before servicing or installing this unit. Multiple power
sources may be present. Failure to do so may cause property damage, personal injury
, or death.
⚡