English
16
n
Setting operation mode (Fig. 12)
[Registration]
1.
Press the OPERATION MODE SELEC-
TOR BUTTON. Each time you press this
button, the display rotates as shown on
the below list.
• List of operations which can be set
In the below list, “
V
” refers to the acceptable set-
ting, while “ × ” refers to the not acceptable setting.
∗
1: Setting may not be acceptable depending on the
type of indoor unit with which this unit is connected.
∗
2: In zone control, the units run in temperature adjust-
ment mode (heating or cooling) for the outdoor sys-
tem for the groups registered to those zones.
Heating or cooling selection is not available.
*3: or or
Changing the ventilation mode cannot be done in
the zone screen. Changing the ventilation mode
should be done in the individual screen.
∗
4: In group control, the units run in temperature adjust-
ment mode (heating or cooling) for the group outdoor
system. Heating or cooling selection is not available.
• The Zone consists of the following two cases.
See page 20 if the display“
” is flashing.
•
Fan operation can be performed for each zone
using the central remote controller even if there is no
cooling/heating selection right during cooling or
heating. Also, if a Ventiair is connected in the zone,
ventilation and ventilation cleaning operation is pos-
sible. See the included operating manuals for
details.
•
When the indoor unit is in heat operation, change the set-
ting to FAN operation through the central remote control-
ler; then, you can switch the fan speed to the extremely
low fan speed. Warm air may blow if any other indoor unit
belonging to the same system is in heat operation.
•
The indoor fan stops during defrost/hot start.
•
DRY cannot be set from the central remote controller.
A. Zone without display“
”
The group with master remote controller setting
exists in this zone.
Setting the master remote controller enables cool/
heat selection.
Operations other than cool/heat operations can also
be set for some operations. For further details, see
the list on the left.
B. Zone with display“
”
No group with master remote controller setting
exists in this zone.
The cool/heat selection is not available because the
master remote controller has not been set.
Some operations other than cool/heat operations
can be set. For further details, see the list in the left.