2
www.daikinac.com
SS-DAX
SS-DAX
www.daikinac.com
3
DAX Specifications
DAX09043**
DAX09044**
DAX12043**
DAX12044**
Total Capacities
Cooling (BTU/h)
90,000
90,000
120,000
120,000
Heating (kW)
15, 20, 30
15, 20, 30
15, 20, 30
15, 20, 30
CFM
3,000
3,000
4,000
4,000
Electrical Data
Voltage-Hz-Phase
208/240-60-3
460-60-3
208/240-60-3
460-60-3
Voltage Range
197 - 253
414-506
197 - 253
414-506
FLA (Total)
13.8
4.6
13.8
4.6
Minimum Circuit Ampacity
15.5/15.5
5.2
15.5/15.5
5.2
Blower Motor
Type
Direct Drive
Direct Drive
Direct Drive
Direct Drive
Horse Power
1
1
1
1
Voltage-Hz-Phase
208/240-60-3
460-60-3
208/240-60-3
460-60-3
FLA/ LRA
6.9/47.7
2.3/23.9
6.9/47.7
2.3/23.9
Blower & Controls
Wheel Dia. & Width (Qty.)
11 x 10 (2)
11 x 10 (2)
11 x 10 (2)
11 x 10 (2)
Nominal Airflow (Ft./Min.)
3,000
3,000
4,000
4,000
Transformer
Standard
Standard
Standard
Standard
Blower Relay
Standard
Standard
Standard
Standard
Filter, Coil & Refrigerant
Disposable Filter Size / Qty
16”x20”x2”/ 2
20”x20”x2”/ 2
16”x20”x2”/ 2
20”x20”x2”/ 2
16”x20”x2”/ 2
20”x20”x2”/ 2
16”x20”x2”/ 2
20”x20”x2”/ 2
Coil Area (sq. ft.)
10
10
10
10
FPI - Rows
14 - 4
14 - 4
14 - 4
14 - 4
Expansion Valve Qty.
2
2
2
2
Refrigerant
R-410A
R-410A
R-410A
R-410A
Liquid Connection (Qty.)
⅜” (2) *
⅜” (2) *
⅜” (2) *
⅜” (2) *
Suction Connection (Qty.)
1⅛” (2)
1⅛” (2)
1⅛” (2) *
1⅛” (2) *
Condensate Drain
¾ FPT
¾ FPT
¾ FPT
¾ FPT
Ship Weight (lbs)
430
430
430
430
* For two refrigerant lines