10
|
Configuration
Installer reference guide
45
FTXM20~42+ATXM20~35R2/5V1B + FTXM50~7
ATXM50R2V1B
Daikin room air conditioner
4P518023-8G – 2020.06
10 Configuration
10.1 To set a different address
In case 2 indoor units are installed in 1 room, different addresses for 2 user
interfaces can be set.
1
Remove the cover and the batteries from the user interface.
2
Cut the address jumper J4.
a
a
Address jumper J4
NOTICE
Be careful NOT to damage any of the surrounding parts when cutting the address
jumper.
3
Turn the power supply on.
4
Press and
simultaneously.
5
Press
, select and press
.
Result:
The operation lamp will start to blink.
ON/
OFF
b
a
a
Operation lamp
b
Indoor unit ON/OFF switch
6
Press the indoor unit ON/OFF switch while the operation lamp is blinking.
Address jumper
Address
Factory setting
1
After cutting with nippers