DAMA-SM-21-003
Main Functions
Functions and Control
29
Note
1.9 Sleep
Mode
Outline
SLEEP Mode can be activated through the remote controller to keep the thermal comfort while
sleeping.
Details
SLEEP Mode continues operation at the target temperature for the first hour, then automatically
raises the target temperature slightly in case of cooling, or lowers it slightly in case of heating.
This prevents excessive cooling in summer and excessive heating in winter to ensure
comfortable sleeping conditions and also saves electricity.
1.10 POWERFUL Operation
Outline
In order to exploit the cooling capacity to full extent, the air conditioner can be operated by
increasing the indoor fan rotating speed and the compressor frequency.
Details
When
POWERFUL
button is pressed, the fan speed and target temperature are converted to
the following states for 20 minutes.
H = high fan
A = refer table below
POWERFUL operation cannot be used together with ECO+ operation.
target temperature
<COOL or DRY>
run
sleep operation
target temperature
<HEAT>
1hr
1hr
(shift 0.5°C/0.9°F)
(no offset on target
temperature)
(shift 1.0°C/1.8°F)
(shift 1.0°C/1.8°F)
(shift 2.0°C/3.6°F)
ON signal of sleep operation
ON signal of sleep opoperation ON signal
OFF signal of sleep operation
operation OFF signal
Operation mode
Fan speed
Target temperature
COOL
H tap + A rpm
Setting temperature -4°C (-7.2°F)
HEAT
H tap + A rpm
Setting tempe6°C (+10.8°F)
Mode
Model
07
09
12
Cool
CTX
100
100
100
Heat
100
100
100
DAMA-SM-21-003 -Inverter Multi Split-CTX Series.book Page 29 Wednesday, September 1, 2021 5:44 PM